RESUMEN
BACKGROUND: Isolate features of the coronary anatomy have been associated with the pathophysiology of atherosclerotic disease. Computational methods have been described to allow precise quantification of the complex three-dimensional (3D) coronary geometry. The present study tested whether quantitative parameters that describe the spatial 3D coronary geometry is associated with the extension and composition of the underlying coronary artery disease (CAD). METHODS: Patients with CAD scheduled for percutaneous intervention were investigated with coronary computed tomography angiography (CCTA), and invasive coronary angiography, and virtual histology intravascular ultrasound (IVUS-VH). For all target vessels, 3D centerlines were extracted from CCTA images and processed to quantify 23 geometric indexes, grouped into 3 main categories as follows: (i) length-based; (ii) curvature-based, torsion-based, and curvature/torsion-combined; (iii) vessel path-based. The geometric variables were compared with IVUS-VH parameters assessing the extent and composition of coronary atherosclerosis. RESULTS: A total of 36 coronary patients (99 vessels) comprised the study population. From the 23 geometric indexes, 18 parameters were significantly (p < 0.05) associated with at least 1 IVUS-VH parameter at a univariate analysis. All three main geometric categories provided parameters significantly related with atherosclerosis variables. The 3D geometric indexes were associated with the degree of atherosclerotic extension, as well as with plaque composition. Geometric features remained significantly associated with all IVUS-VH parameters even after multivariate adjustment for clinical characteristics. CONCLUSIONS: Quantitative 3D vessel morphology emerges as a relevant factor associated with atherosclerosis in patients with established CAD.
Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Ultrasonografía Intervencional/métodos , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/patología , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Valor Predictivo de las PruebasRESUMEN
Clinical guidelines recommend the development of ST-elevation myocardial infarction (STEMI) networks at community, regional and/or national level to ideally offer primary coronary angioplasty, or at least the best available STEMI care to all patients. However, there is a discrepancy between this clinical recommendation and daily practice, with no coordinated care for STEMI patients in many regions of the world. While this can be a consequence of lack of resources, in reality it is more frequently a lack of organisational power. In this paper, the Stent - Save a Life! Initiative (www.stentsavealife.com) proposes a practical methodology to set up a STEMI network effectively in any region of the world with existing resources, and to develop the STEMI network continuously once it has been established.
Asunto(s)
Angioplastia Coronaria con Balón , Infarto del Miocardio , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/cirugía , StentsRESUMEN
BACKGROUND: New-generation drug-eluting stents (DES) reduce target-vessel revascularization compared with bare-metal stents (BMS), and recent data suggest that DES have the potential to decrease the risk of myocardial infarction and cardiovascular mortality. We evaluated the treatment effect of DES versus BMS according to the target artery (left anterior descending [LAD] and/or left main [LM] versus other territories [no-LAD/LM]). METHODS AND RESULTS: The Coronary Stent Trialist (CST) Collaboration gathered individual patient data of randomized trials of DES versus BMS for the treatment of coronary artery disease. The primary outcome was the composite of cardiac death or myocardial infarction. Hazard ratios (HRs) with 95% CIs were derived from a 1-stage individual patient data meta-analysis. We included 26 024 patients across 19 trials: 13 650 (52.4%) in the LAD/LM and 12 373 (47.6%) in the no-LAD/LM group. At 6-year follow-up, there was strong evidence that the treatment effect of DES versus BMS depended on the target vessel (P interaction=0.024). Compared with BMS, DES reduced the risk of cardiac death or myocardial infarction to a greater extent in the LAD/LM (HR, 0.76; 95% CI, 0.680.85) than in the no-LAD/LM territories (HR, 0.93; 95% CI, 0.831.05). This benefit was driven by a lower risk of cardiac death (HR, 0.83; 95% CI, 0.700.98) and myocardial infarction (HR, 0.74; 95% CI, 0.650.85) in patients with LAD/LM disease randomized to DES. An interaction (P=0.004) was also found for all-cause mortality with patients with LAD/LM disease deriving benefit from DES (HR, 0.86; 95% CI, 0.760.97). CONCLUSIONS: As compared with BMS, new-generation DES were associated with sustained reduction in the composite of cardiac death or myocardial infarction if used for the treatment of LAD or left main coronary stenoses.
Asunto(s)
Stents , Stents Liberadores de FármacosRESUMEN
BACKGROUND/PURPOSE: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)- based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation. METHODS AND RESULTS: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of −1.857 ± 1.902 mm2 at 1 year compared to −1.277 ± 1.562 mm2 in the intermediate-ESS segment (P = 0.017) and − 0.709 ± 1.213 mm2 in the high-ESS segment (P = 0.001). CONCLUSION: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss. SUMMARY FOR TABLE OF CONTENTS: The authors analyzed 22 patients from the BIOSOLVE-II trial who underwent optical coherence tomography assessment immediately after receiving a Magmaris second-generation drug-eluting resorbable magnesium scaffold. The analysis found that after Magmaris implantation, the presence of higher endothelial shear stress (ESS) might be associated with slower strut absorption process but less luminal loss. This study is the first demonstrating the impact of ESS assessed by OCT on absorption process and coronary lumen dimension after Magmaris implantation.
Asunto(s)
Implantes Absorbibles , Tomografía de Coherencia Óptica , Magnesio , Resistencia al Corte , Stents Liberadores de FármacosRESUMEN
AIMS : Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is an alternative novel device for treating coronary lesions. However, the relationship between in-scaffold dimensions after implantation of DREAMS 2G and vessel healing and luminal results at follow-up is unknown. The aim of this study is, therefore, to investigate whether the expansion index after implantation of DREAMS 2G as assessed by optical coherence tomography (OCT) impacts late luminal status and healing of the vessel wall. METHODS AND RESULTS : This study comprises of a total 65 out of 123 patients who were enrolled in the BIOSOLVE-II trial. We assessed both qualitative and quantitative OCT findings and the expansion index of DREAMS 2G after implantation frame by frame using OCT. Expansion index was defined as minimum scaffold area/mean reference lumen area. The over-expansion group was also defined with expansion index >1.0. The total number of analyzed frames at post-procedure and 6-month follow-up was 8243 and 8263 frames, respectively. At 6-month follow-up, in-scaffold healing was documented by the reduction of 82% in dissections, 93% in attached intra-luminal mass (ILM), 65% in non-attached ILM, and 76% in jailed side branch. The over-expansion group had significantly greater in-scaffold luminal volume loss (LVL) compared with the non-over-expansion group [over-expansion: 35.0 (18.5-52.1) mm3 vs. non-over-expansion: 21.0 (11.6-37.9) mm3, P = 0.039]. CONCLUSION : Excellent in vivo healing process after implantation of DREAMS 2G was observed at 6 months. We found that higher expansion indices were associated with higher in-scaffold LVL at 6 months assessed by OCT. (AU)
Asunto(s)
Vasos Coronarios , Tomografía de Coherencia Óptica , Stents Liberadores de FármacosRESUMEN
Background The aim of this study was to compare the 12-month clinical outcomes of patients treated with Magmaris or Orsiro. Second generation drug-eluting absorbable metal scaffold Magmaris (Dreams 2G) has proved to be safe and effective in the BIOSOLVE-II study. Similarly, biodegradable polymer sirolimus-eluting stent, Orsiro has shown notable clinical results even in all-comer populations. Methods Magmaris group patients were taken from the BIOSOLVE-II and BIOSOLVE-III trials, while the patients from Orsiro group were enrolled in BIOFLOW-II trial. The primary outcome was explored using a time-to-event assessment of the unadjusted clinical outcomes for target lesion failure (TLF) at 12â¯months, followed by a multivariate analysis adjusting for all the significantly different covariates between the groups. Results The study population consisted of 482 patients (521 lesions), 184 patients (189 lesions) in Magmaris group and 298 patients (332 lesions) in Orsiro group. The mean age was 65.5⯱â¯10.8 and 62.7⯱â¯10.4â¯years in Magmaris and Orsiro groups, respectively ( pâ¯=â¯0.005). Magmaris and Orsiro unadjusted TLF rates were 6.0 and 6.4% with no significant difference between the groups ( pâ¯=â¯0.869). In the multivariate analysis, there were no meaningful differences between Magmaris and Orsiro groups. Finally, none of the groups presented device thrombosis cases at 12â¯months. Conclusion At 12â¯months there were no significant differences between Magmaris and Orsiro groups neither in the unadjusted assessment nor in the multivariate analysis for target lesion failure. These results should be taken as hypothesis generating and may warrant a head to head comparison on a randomized fashion.
Asunto(s)
Análisis Multivariante , Stents Liberadores de Fármacos , SirolimusRESUMEN
Introduction and objective: The edge vascular response (EVR) remains unknown in second generation drugeluting Resorbable Magnesium Scaffold (RMS), such as Magmaris. The aim of the study was to evaluate tissue modifications in the RMS edges over time, assessed by different invasive imaging modalities. Methods: The patients treated with the device were assessed by optical coherence tomography (OCT), grayscale intravascular ultrasound (IVUS), and virtual histology IVUS at baseline and 12 months. The EVR study performed a segment- and frame-level analysis of the 5 mm segments proximal and distal of the actual RMS. Results: The segment-level grayscale IVUS (n=10), virtual histology IVUS (n=10), and OCT (n=18) analysis did not showany significant changes after 12months, except for a fibrous plaque area (FPA) reduction of 0.5mm2 (p=0.017) in the proximal segment compared to baseline. In the frame-level analysis, IVUS evaluation revealed a vessel area decreased 2.80 ± 1.43 mm2 (p = 0.012) and 2.49 ± 1.53 mm2 (p = 0.022) in 2 proximal frames. This was accompanied by plaque area reduction of 0.88 ± 0.70 mm2 (p = 0.048) and a FPA decreased by 0.63 ± 0.48mm2 (p = 0.004) in one proximal frame. In 1 distal frame, there was a dense calcium area reduction of 0.10 ± 0.12 mm2 (p = 0.045), FPA and fibrous fatty plaque increased 0.54 ± 0.53 mm2 (p = 0.023) and 0.17 ± 0.16 mm2 (p = 0.016), respectively. By OCT, there was a lumen area decrease of 0.76 ± 1.51 mm2 (p = 0.045) in a distal frame. Conclusion: At 12 months, Magmaris EVR assessment does not show overall significant changes, except for a fibrous plaque area reduction in the proximal segment. This could be translated as a benign healing process a the edges of the RMS. Summary: The edge vascular response (EVR) remains unknown in second generation drug-eluting absorbable metal scaffolds (RMS), such as Magmaris. Patients treated with the device were assessed by multi invasive imagingmodalities [i.e. optical coherence tomography (OCT), grayscale intravascular ultrasound (IVUS), and virtual histology IVUS] evaluating the tissue changes over timein the segment- and frame-level analysis of the 5mm segments proximal and distal of the actual RMS. As a result, after 12months, Magmaris EVR assessment does not show overall significant changes, except for a fibrous plaque area reduction in the proximal segment, translating a benign healing process at the edges of the RMS.
Asunto(s)
Humanos , Ultrasonografía Intervencional , Tomografía de Coherencia ÓpticaRESUMEN
Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is used for treating coronary lesions. However, the natural history of the jailed side-branch (SB) after DREAMS 2G implantation remains to be elucidated. The aim of this study is to investigate the effect of scaffold struts on jailed SBs as assessed by 3-dimensional (3D) optical coherence tomography (OCT) after implantation of DREAMS 2G. We enrolled the patients who received a DREAMS 2G implantation and where OCT was performed at postprocedure and 12-month follow-up in the BIOSOLVE-II trial. The area of the ostium of jailed SBs and number of compartments divided by scaffold struts were assessed by cut-plane analysis using 3D OCT. A total of 24 patients with 61 jailed SBs were analyzed in this study. The number of compartments was significantly decreased (postprocedure; 1.98 +/- 0.84 vs 12 months; 1.10 +/- 0.30, p <0.001) during the 12 months. Since most of the struts disappeared, the ostium area was increased in 62% of jailed SBs at 12 months, however, not significantly different from postprocedure (postprocedure; 0.74 [0.34 to 1.46] mm(2) vs 12 months; 0.78 [0.41 to 1.68] mm(2), p=0.055). The number of compartments created by scaffold struts and branching angle at postprocedure had no effect on the changes of SB ostium área. DREAMS 2G has a favorable absorption process in the jailed SBs up to 12 months and may be considered as an optional therapy for treating lesions that involve SBs. (AU)
Asunto(s)
Humanos , Enfermedad de la Arteria Coronaria , Tomografía de Coherencia Óptica , Stents Liberadores de FármacosRESUMEN
RATIONALE: Bioresorbable scaffolds may confer clinical benefit in long-term studies; early mechanistic studies using intravascular imaging have provided insightful information about the immediate and mid-term local serial effects of BRS on the coronary vessel wall. OBJECTIVES: We assessed baseline, 6- and 12-month imaging data of the drug-eluting absorbable metal scaffold (DREAMS 2G). METHODS AND RESULTS: The international, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to 2 de novo lesions (in vessels of 2.2 to 3.7mm). Angiographic based vasomotion, curvature and angulation were assessed; intravascular ultrasound (IVUS) derived radiofrequency (RF) data analysis and echogenicity were evaluated; optical coherence tomography (OCT) attenuation and backscattering analysis were also performed. There was hardly any difference in curvature between pre-procedure and 12months (-0.0019; p=0.48). The change in angulation from pre- to 12months was negligible (-3.58°; 95% CI [-5.97, -1.20]), but statistically significant. At 6months, the change in QCA based minimum lumen diameter in response to high dose of acetylcholine and IVUS-RF necrotic core percentage showed an inverse relationship (estimate of -0.489; p=0.055) and with fibrous volume a positive relationship (estimate of 0.53, p=0.035). Bioresorption analysis by OCT showed that the maximum attenuation values decreased significantly from post-procedure at 6months (Δ 6months vs. post-proc. is -13.5 [95% CI -14.6, -12.4]) and at 12months (Δ 12months vs. post-proc. is -14.0 [95% CI -15.4, -12.6]). By radiofrequency data, the percentage of dense calcium decreased significantly from post-procedure at 6months and at 12months...
Asunto(s)
Enfermedad de la Arteria Coronaria , Sirolimus , Stents Liberadores de FármacosRESUMEN
AIMS: We aimed to assess the safety and performance of the DREAMS 2G scaffold up to 24 months post implant. METHODS AND RESULTS: The present study population comprises a total of 184 patients with 189 lesions who were enrolled in the prospective, multicentre BIOSOLVE-II and BIOSOLVE-III trials. Clinical follow-up was scheduled at one, six, 12, 24 and 36 months. The present report includes pooled follow-up data at six months and BIOSOLVE-II data at 24 months. Patients were 65.5±10.8 years old, and lesions were 12.5±5.1 mm long with reference diameters of 2.7±0.4 mm. Procedural success was obtained in 97.8%. At six months, the composite clinical endpoint target lesion failure was 3.3% (95% CI: 1.2-7.1), based on two cardiac deaths (1.1%, one unknown and one not device-related), one target vessel myocardial infarction (0.6%), and three clinically driven target lesion revascularisations (1.7%). For BIOSOLVE-II at 24 months, the target lesion failure rate was 5.9% (95% CI: 2.4-11.8), based on two cardiac deaths (1.7%), one target vessel myocardial infarction (0.9%) and four target lesion revascularisations (3.4%). There was no definite or probable scaffold thrombosis...
Asunto(s)
Corazón , Enfermedades Cardiovasculares , Estudios de Casos y Controles , Stents Liberadores de FármacosRESUMEN
Aims: Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomesof a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesiumscaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. Methods and results: The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novolesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at6 months, andif subjects consentedat 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42patients: in-segment late lumen loss 0.20 + 0.21 mm vs. 0.25 + 0.22 mm, P » 0.117, D 0.05 + 0.21 mm (95%CI: 20.01;0.12); in-scaffold late lumen loss 0.37 + 0.25 mm vs. 0.39 +0.27 mm, P » 0.446, D 0.03 + 0.22 (95%CI: 20.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroboratedthe QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause,one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional eventoccurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienceda definite or probable scaffold thrombosis...
Asunto(s)
Enfermedad de la Arteria Coronaria , Magnesio , Sueños , StentsRESUMEN
Background Absorbable scaffolds were designed to overcome the limitations of conventional, non-absorbable metal-based drug-eluting stents. So far, only polymeric absorbable scaffolds are commercially available. We aimed to assess the safety and performance of a novel second-generation drug-eluting absorb...
Asunto(s)
Implantes Absorbibles , StentsRESUMEN
BackgroundDrug-eluting stents reduce restenosis and reintervention rates but are complicated by stent thrombosis,which may be related to polymer coating. The NEVO sirolimus-eluting coronary stent (NEVO SES) is designed to improve long-term percutaneous coronary intervention safety by combining sirolimus release from reservoirs withbioabsorbable polymer to reduce spatial and temporal polymer exposure.Methods and ResultsNEVO ResElution-I was a prospective randomized study in 394 patients with coronary arterydisease comparing the NEVO SES with the TAXUS Liberte´ paclitaxel-eluting coronary stent (TAXUS Liberte´ PES)stent. The primary end point was in-stent angiographic late loss at 6 months. Six months after percutaneous coronaryintervention (PCI), the primary end point favored NEVO SES (0.13 0.31 mm versus 0.36 0.48 mm, P 0.001 fornoninferiority and superiority). The study was not powered for clinical end points and showed no significant differencefor NEVO SES versus TAXUS Liberte´ PES: death: 0.5 versus 1.6%, P 0.36; myocardial infarction: 2.0 versus 2.6%,P 0.75; target lesion revascularization: 1.5 versus 3.2%, P 0.33; major adverse cardiac events: 4.0 versus 7.4%, P 0.19.No stent thrombosis was observed with NEVO SES, whereas 2 cases occurred in TAXUS Liberte´ PES. Intravascularultrasound showed lower percent volume obstruction for NEVO SES (5.5 11% versus 11.5 9.7%, P 0.016).ConclusionsThis trial proved the superiority of NEVO SES over TAXUS Liberte´ PES for the primary angiographic endpoint of in-stent late loss. No stent thrombosis occurred in the NEVO SES group.
Asunto(s)
Angioplastia , Reestenosis Coronaria , StentsRESUMEN
BackgroundThe expanding indications for sirolimus-eluting stents (SES) include increasingly complex coronary lesions and populations with clinical profiles markedly different from those of early pivotal controlled studies. The e-Cypher registry monitored the safety and efficacy of SES currently implanted worldwide in daily practice. Methods and ResultsBetween April 2002 and September 2005, data were collected on 15 157 patients who underwent implantation of 1 SES at 279 medical centers from 41 countries. An independent endpoint review committee adjudicated all reported major adverse cardiovascular events, stent thromboses, and target-vessel revascularizations. Data were managed and analyzed by independent organizations. Predictors of adverse clinical events were identified by regression analysis. The mean age of the sample was 61.7 11.4 years; 77.7% were men, and 28.6% were diabetics. A total of 18 295 lesions were treated (20 503 SES) during the index procedure. The cumulative rates of major adverse cardiovascular events were 1.36% at 30 days, 3.38% at 6 months, and 5.80% at 1 year. The rates of acute, subacute, and late stent thrombosis were 0.13%, 0.56%, and 0.19% of patients, respectively, representing a 12-month actuarial incidence of 0.87%. Insulin-dependent diabetes, acute coronary syndrome at presentation, and advanced age were clinical predictors, whereas TIMI flow grade 3 after the index procedure, treatment of multiple lesions, a prominently calcified or totally occluded target lesion, and multivessel disease were the angiographic or procedural predictors of stent thrombosis at 12 months. ConclusionsThis analysis of 1-year data collected by the e-Cypher registry suggests a high degree of safety of SES, with a rate of stent thrombosis similar to that observed in randomized trials.
Asunto(s)
Directorio/estadística & datos numéricos , Enfermedad Coronaria , Revascularización Miocárdica , Stents , Trombosis CoronariaRESUMEN
BackgroundThe expanding indications for sirolimus-eluting stents (SES) include increasingly complex coronary lesions and populations with clinical profiles markedly different from those of early pivotal controlled studies. The e-Cypher registry monitored the safety and efficacy of SES currently implanted worldwide in daily practice. Methods and ResultsBetween April 2002 and September 2005, data were collected on 15 157 patients who underwent implantation of 1 SES at 279 medical centers from 41 countries. An independent endpoint review committee adjudicated all reported major adverse cardiovascular events, stent thromboses, and target-vessel revascularizations. Data were managed and analyzed by independent organizations. Predictors of adverse clinical events were identified by regression analysis. The mean age of the sample was 61.7 11.4 years; 77.7% were men, and 28.6% were diabetics. A total of 18 295 lesions were treated (20 503 SES) during the index procedure. The cumulative rates of major adverse cardiovascular events were 1.36% at 30 days, 3.38% at 6 months, and 5.80% at 1 year. The rates of acute, subacute, and late stent thrombosis were 0.13%, 0.56%, and 0.19% of patients, respectively, representing a 12-month actuarial incidence of 0.87%. Insulin-dependent diabetes, acute coronary syndrome at presentation, and advanced age were clinical predictors, whereas TIMI flow grade 3 after the index procedure, treatment of multiple lesions, a prominently calcified or totally occluded target lesion, and multivessel disease were the angiographic or procedural predictors of stent thrombosis at 12 months. ConclusionsThis analysis of 1-year data collected by the e-Cypher registry suggests a high degree of safety of SES, with a rate of stent thrombosis similar to that observed in randomized trials
Asunto(s)
Enfermedad de la Arteria Coronaria , Revascularización Miocárdica , Stents , TrombosisRESUMEN
The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analys of the local biological effects of the implantation of a sirolimus-eluting stens compared with an uncoated stent. In the RAVEL trial, 238 patients with sigle de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx velocity Stent)...