Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Sci Pollut Res Int ; 31(23): 33942-33959, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38691286

RESUMEN

This study evaluates the quality of 30 biomass pellets sold for residential use in Poland. It provides data on their physical, chemical, and petrographic properties and compares them to existing standards and the information provided by the fuel producers. The results reveal considerable variations in the quality of the pellets and show that some of the purchased samples are not within the DINplus and/or ENplus certification thresholds. Among all 30 purchased samples, only one passes the quality thresholds set by the PL-US BIO, a newly established quality certification in Poland that combines quality assessment following DINplus with optical microscopy analysis. The primary issues causing a decrease in pellet quality include elevated ash and fines content, compromised mechanical durability, too low ash melting temperature, and additions of undesired additions like bark, inorganic matter, and petroleum products. Our research highlights the need for improved fuel quality control measures, and transparent and accurate product labeling, as well as the need for a comprehensive and publicly available national database of solid biomass fuel producers and fuels sold. These are essential steps toward increasing customers' awareness and trust, encouraging them to embrace biomass fuels as reliable and sustainable sources of energy.


Asunto(s)
Biomasa , Polonia
2.
Environ Monit Assess ; 195(11): 1393, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37906283

RESUMEN

Currently, there is a lack of research directly comparing the precision of automatic weighing systems and manual weighing in the context of particulate matter (PM) filter equilibration and measurements under different humidity conditions. During experimental measurements, three different types of PM-loaded filters were weighed using manual and automatic balances. During manual weighing, every filter was weighed twice in three different relative humidity conditions. The same procedure was done using an automated weighing system. In most cases, it was found that under relative humidities in the range of 30-55% RH, the manual and automated methods can be treated as referential. Regarding device stability, very slight but overall better precision was found for 30% RH, suggesting that 40 CFR Part 50, Appendix L requirements regarding conditioning humidity (30-40% RH) seem more suitable than those presented in the PN-EN 12341:2014 standard (45-50% RH). Understanding the effects of the influence of the RH% on PM mass measurements is a matter of great importance, because water vapor condensed on a filter can affect the particulate matter concentrations. This is especially important in areas where regulatory limits are exceeded. Calculation of uncertainty in the PM mass measurements is therefore crucial for determining the actual sample mass and improving air monitoring practices. In a nutshell, the experimental results obtained clearly describe how changing RH% conditions affect the PM weighing precision during manual and automated measurements.


Asunto(s)
Contaminantes Atmosféricos , Material Particulado , Material Particulado/análisis , Humedad , Contaminantes Atmosféricos/análisis , Monitoreo del Ambiente/métodos
3.
Environ Monit Assess ; 195(11): 1373, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37880548

RESUMEN

This study aimed to assess the potential risks posed by heavy metals in sewage sludge (SS) produced by municipal wastewater treatment plants (WWTPs) in the most industrialized region in Poland, the Silesian Voivodeship. The ecological risk was assessed using three indices: the Geoaccumulation Index (Igeo), Potential Ecological Risk Factor (ER), and Risk Assessment Code (RAC), while the health risk was estimated by using carcinogenic and non-carcinogenic risk indices. The average concentrations of metals in the sludge samples were determined revealing that Zn was the predominant element, whereas Cd and Hg were present in the lowest concentrations. The study showed that the processes used in wastewater treatment plants influenced the overall metal content and chemical speciation. According to Igeo values, the dewatered sludge samples exhibited higher contamination levels of Cd and Zn, while Cu and Pb were upon to a lesser extent. The ER values suggest that Cd and Hg present the highest ecological risk. Considering the chemical forms and RAC values, Ni (26.8-37.2%) and Zn (19.8-27.0%) were identified to cause the most significant risks. The non-carcinogenic risk for adults and children was below acceptable levels. However, the carcinogenic risk associated with Ni (WWTP1) for both demographic groups and Cr and Cd (WWTP2), specifically for children, exceeded the acceptable threshold. Ingestion was the primary route of exposure. Although the dewatered SS met the standards for agricultural use, there is still a risk of secondary pollution to the environment and possible adverse health effects.


Asunto(s)
Mercurio , Metales Pesados , Contaminantes del Suelo , Adulto , Niño , Humanos , Aguas del Alcantarillado/análisis , Polonia , Cadmio , Monitoreo del Ambiente , Metales Pesados/análisis , Medición de Riesgo , China , Suelo/química , Contaminantes del Suelo/análisis
4.
Molecules ; 27(15)2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35956897

RESUMEN

The purpose of this study was to determine the heavy metal (HM: Cd, Cr, Cu, Ni, Pb, Zn, and Hg) content in particular chemical fractions (forms) of sewage sludge with different characteristics (primary and dewatered sludge) using conventional (CSE) and ultrasound-assisted (USE) BCR sequential extraction methods (Community Bureau of Reference, now the Standards, Measurements and Testing Programme). The concentrations of HMs were determined using inductively coupled plasma optical spectrometry (ICP-OES). Only mercury was assayed with cold vapor atomic absorption spectrometry (CVAAS). Ultrasound treatment was conducted in the ultrasonic bath (Sonic 5, Polsonic). The optimal sonication time (30 min) was determined using ERM-CC144 (Joint Research Center; JCR) certified reference material. The conducted experiment revealed that the use of ultrasound waves shortened the extraction time to 4 h and 30 min (Stages I to III). The recoveries (RM) of heavy metals ranged from 62.8% to 130.2% (CSE) and from 79.8% to 135.7% (USE) for primary sludge, and from 87.2% to 113.2% (CSE) and from 87.8% to 112.0% (USE) for dewatered sludge. The only exception was Hg in dewatered sludge. The conducted research revealed minor differences in the concentrations and fractionation patterns for Cd, Ni, and Zn extracted from sludge samples by the tested methods. However, it was confirmed that the above findings do not significantly affect the results of a potential ecological risk assessment (with minor exceptions for Cd and Zn in the primary sludge), which is extremely essential for the natural use of sludge, and especially dewatered sludge (the final sludge). The shorter extraction time and lower energy consumption prove that ultrasound-assisted extraction is a fast and simple method for HM fractionation, and that it provides an alternative to the conventional procedure. Therefore, it can be considered a "green method" for the assessment of the bioavailability and mobility of heavy metals in solid samples.


Asunto(s)
Mercurio , Metales Pesados , Cadmio , Fraccionamiento Químico , Metales Pesados/análisis , Aguas del Alcantarillado/análisis
5.
J Hazard Mater ; 440: 129635, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-36027742

RESUMEN

The manuscript presents an innovative and holistic approach to quantifying PAHs and BTEX emissions from the grilling process and indicates a novel driven-toxicity-based solution to recognize health effects related to BBQ emissions. The exposure scenario includes the type of grilling device, food type, and individual attitudes, but also a keen understanding of the broad health implications related to the gaseous/particulate PAHs emission, or age-related effects. The calculated incremental lifetime cancer risk (ILCR) associated with the exposure to PAH congeners and BTEX indicates an unacceptable level in the case of charcoal and briquette grilling with the highest values for professional cooks. The sum of 15 PAH concentrations in grilled foods was highest for meat grilling over charcoal briquettes - 382,020.39 ng/m3 and lowest for meat grilling on a gas grill - 1442.16 ng/m3. The emissions of BTEX from lump charcoal grilling were 130 times higher compared to the gaseous grill. In all considered scenarios lump-charcoal and charcoal briquettes grilling derive the ILCR above the 10-4, indicating negative effects of traditional grills on human health. The paper completes knowledge of wide-ranging health implications associated with BBQs, a topic that is almost completely unaddressed among the scientific community and policymakers.


Asunto(s)
Contaminantes Atmosféricos , Hidrocarburos Policíclicos Aromáticos , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Carbón Orgánico/análisis , Culinaria , Gases , Humanos , Exposición por Inhalación/análisis , Carne/análisis , Hidrocarburos Policíclicos Aromáticos/análisis , Hidrocarburos Policíclicos Aromáticos/toxicidad , Medición de Riesgo
6.
Artículo en Inglés | MEDLINE | ID: mdl-32664556

RESUMEN

This study concerns the concentrations of gaseous and particle-bound mercury present in ambient air of two Polish sites, differing in terms of emission structure, and the estimation of inhalation risks related to those Hg species. The measurements of total gaseous mercury (TGM) and PM2.5-bound mercury (PBM) were performed at an urban station in Zabrze and a rural station in Zloty Potok, in 2014-2015. Both sites are located in Silesia, considered one of the European air pollution hot-spots. TGM was measured on-line (Tekran 2537). PM2.5 samples were taken with the use of low volume samplers. Hg contents in PM were determined by the CVAAS method following thermal decomposition. The median concentrations of TGM and PBM in Zabrze were 2.48 ng m-3 and 37.87 pg m-3, respectively; meanwhile in Zloty Potok, these were 1.69 ng m-3 and 27.82 pg m-3, respectively. Clearly, seasonal variability of TGM and PBM concentrations were observed, reflecting the importance of Hg and PM emissions from coal combustion for power and heating purposes. Health risk assessment was performed using a deterministic approach by the most conservative exposure scenario. The obtained HQ ratios and the cumulative HI indexes were below the limit value (<1). This means an unlikely health hazard due mercury inhalation.


Asunto(s)
Contaminantes Atmosféricos/análisis , Exposición por Inhalación/efectos adversos , Mercurio/efectos adversos , Carbón Mineral , Monitoreo del Ambiente , Gases , Humanos , Mercurio/análisis , Polonia , Medición de Riesgo
7.
Artículo en Inglés | MEDLINE | ID: mdl-32709113

RESUMEN

The present study describes the effects of temperature and humidity on the level of water absorption by filter blanks most popularly used for gravimetric analyzes of particulate matter (PM) and the effects of those on the accuracy of its weight measurements. The main parts of the research quantified the effect of temperature and humidity conditions on water contents quartz fiber (Q), fiberglass (G), PTFE, and nylon (N) filters. Supplementary studies were conducted to estimate the effects of temperature, humidity and material on mass loss/gain and the shape of water retention. All chemical analyses of water contents were performed by the Karl Fischer titration method. The results indicate that quartz filters are the most susceptible to the variations in water contents under changing humidity levels and therefore, less suitable to high accuracy determinations of PM mass compared to nylon or glass filters; PTFE performed the best due to their hydrophobicity. For PM water contents determinations, the best choice of filter media is PTFE. Although many other factors determine the choice of filter type for PM analyses, the present study is an important contribution to knowledge of assessing the suitability of different types of filter material for specific measurements.


Asunto(s)
Contaminantes Atmosféricos , Material Particulado , Contaminantes Atmosféricos/análisis , Monitoreo del Ambiente , Humedad , Material Particulado/análisis , Temperatura , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA