Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 347
Filtrar
1.
J Prosthodont ; 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39267252

RESUMEN

PURPOSE: To investigate the effect of different post-curing light intensities on the trueness, compressive strength, and resin polymerization of 3D-printed 3-unit fixed dental prostheses (FPD). MATERIALS AND METHODS: A total of 60 specimens were prepared to support a 3-unit FDP with a deep chamfer marginal design, utilizing computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Light-polymerizing FDP resin with varying light intensities (105, 210, 420, and 840 mW/cm2) was employed for 10 min. Subsequently, trueness assessment, fracture load testing, scanning electron microscopy (SEM) surface examination, and Fourier-Transform Infrared (FTIR) analysis were conducted. A one-way analysis of variance (ANOVA) was performed to ascertain the differences between the experimental groups (p < 0.05). RESULTS: The group exposed to 210 mW/cm2 showed the highest trueness (57.6 ± 2.1 µm), while the 840 mW/cm2 group had the highest deviation (79.3 ± 2.7 µm) (p < 0.001). Significant differences in fracture resistance were found between groups (p < 0.001), with mean fracture strengths of 1149.77 ± 67.81 N, 1264.92 ± 39.06 N, 1331.34 ± 53.62 N, and 1439.93 ± 34.58 N for light intensities of 105, 210, 420, and 840 mW/cm2, respectively (p < 0.001). The resin polymerization analysis shows a peak intensity surge at 3579 cm-1 for O-H and C-H stretching vibrations, except in samples exposed to 105 mw/cm2 light, with the lowest peak at 2890 cm-1. The performance of resin polymerization is most significant under the condition of 840 mW/cm2. CONCLUSION: The light intensity of 210 mW/cm2 exhibited the highest trueness, while the 840 mW/cm2 group showed the highest deviation. However, the light intensity of 840 mW/cm2 demonstrated the highest compressive strength. Furthermore, polymerization occurred at all post-treatment light intensities except 105 mW/cm2. These findings indicate that while low-intensity usage offers greater trueness, high-intensity usage provides better compressive strength and polymerization. Therefore, 210 mW/cm2 could be the recommended solution for post-curing.

2.
Int J Prosthodont ; : 1-29, 2024 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-39110950

RESUMEN

The review focuses on the progressive role of 3D-printing in dentistry, particularly emphasizing the use of zirconia-based and lithium disilicate (LS2) -based ceramic materials. Celebrated for their biocompatibility and esthetic resemblance to natural teeth, these materials have shown promising results with high success rates. Digital light processing (DLP) and stereolithography (SLA) have been noted for producing superior 3D-printed ceramic products. Despite facing challenges such as surface defects, mechanical strength limitations, and esthetic inconsistencies, active research is dedicated to refining the quality and esthetics of 3D-printed zirconia-based and LS2-based ceramics. The review acknowledges the need to mitigate the steep costs of this manufacturing form and recognizes the current shortfall in clinician and technician awareness of these advanced techniques. Addressing these issues through focused research on improving surface quality, dimensional accuracy, and mechanical properties of 3D-printed dental prostheses is crucial, as is enhancing the dental community's understanding and acceptance of this innovative technology.

3.
Front Pharmacol ; 15: 1442297, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39170703

RESUMEN

Objective: This study reviews the development of rhubarb processing and the current status of pharmacological research. We summarized the effects of different processing methods on the active compounds, pharmacological effects, and toxicity of rhubarb, as well as the clinical application of different concoctions, providing reference for further pharmacological research and clinical application of rhubarb. Methods: A comprehensive literature review was conducted using databases such as Pubmed, Embase, National Science and Technology Library, Web of science, CNKI, China Science and Technology Journal Database, SinoMed, and the Pharmacopoeia of the People's Republic of China. Search terms included "rhubarb", "raw rhubarb", "wine rhubarb", "cooked rhubarb", "rhubarb charcoal", "herbal processing", "compounds", "pharmacological effects", "inflammation", "gastrointestinal bleeding", and "tumor". Results: Historical records of rhubarb processing date back to the Han Dynasty, with continual innovations. Currently, the types of rhubarb used in traditional Chinese medicine have stabilized to three species: Rheum palmatum L., Rheum tanguticum Maxim.ex Balf. and Rheum officinale Baill. Common concoctions include raw rhubarb, wine rhubarb, cooked rhubarb and rhubarb charcoal. The active compounds of rhubarb are known to defecation, exhibit antibacterial and anti-inflammatory properties, regulate coagulation, protect the digestive system, and possess anti-tumor activities. Guided by Chinese medicine theory, the use of different rhubarb concoctions can enhance specific effects such as purgation to eliminate accumulation, clearing heat and toxins, cooling blood to stop hemorrhages, activating blood circulation to remove blood stasis, and inducing dampness to descend jaundice, thereby effectively treating various diseases. The therapeutic impact of these concoctions on diseases reflects not only in the changes to the active compounds of rhubarb but also in the formulations of traditional Chinese medicine. Processing has also shown advantages in reducing toxicity. Conclusion: Different processing methods alter the active compounds of rhubarb, thereby enhancing its various pharmacological effects and meeting the therapeutic needs of diverse diseases. Selecting an appropriate processing method based on the patient's specific conditions can maximize its pharmacological properties and improve clinical outcomes.

4.
Orthop Nurs ; 43(4): 195-201, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39047269

RESUMEN

This article is the sixth in the Movement is Life series and focuses on insurance coverage and medication management in the perioperative period, 2 tangentially related variables that affect patient outcomes. Our aim is to use current practices and literature to develop recommendations for nurse navigators' execution of preoperative optimization protocols related to payer status and medication management. Discussions with nurse navigators and a literature search were used to gather information and develop recommendations specific to optimizing payer status and medication management. Nurse navigators connected patients to resources and provided education regarding financial concerns and medications, and findings from the literature discussed insurance status among TJA patients. Nurse navigators can contribute to payer status and medication management optimization by providing patient education and resource referrals. In addition, we recommend conducting repeated medication reconciliation and developing awareness of financial resources and perioperative medication management guidelines.


Asunto(s)
Navegación de Pacientes , Humanos , Enfermería Ortopédica , Artroplastia de Reemplazo , Cuidados Preoperatorios/métodos , Cobertura del Seguro , Administración del Tratamiento Farmacológico/normas
5.
Front Pharmacol ; 15: 1426972, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39035992

RESUMEN

Objective: This study evaluates the research developments concerning Rehmanniae Radix in ovarian hypofunction diseases. It explores the processing methods of Rehmanniae Radix, the variations in its compounds before and after processing, the mechanism of Rehmanniae Radix and its active compounds in improving ovarian function, and the advancements in clinical applications of traditional Chinese medicine (TCM) compound that include Rehmanniae Radix. Methods: Comprehensive literature search was conducted using databases such as China National Knowledge Infrastructure (CNKI), China Science and Technology Journal Database, National Science and Technology Library, the Pharmacopoeia of the People's Republic of China, Pubmed, and the Web of Science Database. The search utilized the following Medical Subject Headings (MeSH) and keywords: "Rehmanniae Radix," "Drying Rehmannia Root," "Rehmannia glutinosa," "Rehmanniae Radix Praeparata," "Traditional Chinese Medicine Processing," "Pharmacological Effects," "Ovarian Aging," "Diminished ovarian reserve," "Premature ovarian insufficiency," "Premature Ovarian Failure," "Ovarian hypofunction diseases". Results: The ancient Chinese medical books document various processing techniques for Rehmanniae Radix. Contemporary research has identified changes in its compounds processing and the resultant diverse therapeutic effects. When processed into Rehmanniae Radix Praeparata, it is noted for its ability to invigorate the kidney. TCM compound containing Rehmanniae Radix is frequently used to treat ovarian hypofunction diseases, demonstrating significant clinical effectiveness. The key changes in its compounds processing include cyclic dilute ether terpene glycosides, phenylethanol glycosides, sugars, and 5-hydroxymethylfurfural. Its pharmacological action is primarily linked to the improvement of granulosa cell proliferation, antioxidative and anti-aging properties, and modulation of the immune and inflammatory microenvironment. Furthermore, Rehmanniae Radix also offers therapeutic benefits for cardiovascular and cerebrovascular diseases, osteoporosis and cognitive dysfunction caused by low estrogen levels. Thereby Rehmanniae Radix mitigates both the short-term and long-term health risks associated with ovarian hypofunction diseases. Conclusion: Processed Rehmanniae Radix has shown potential to improve ovarian function, and its compound prescriptions have a definite effect on ovarian dysfunction diseases. Therefore Rehmanniae Radix was garnering interest for both basic and clinical research, with promising application prospects as a future therapeutic agent for ovarian hypofunction diseases. However, further studies on its toxicology and the design of standardized clinical trials are necessary to fully establish its efficacy and safety.

6.
J Prosthodont ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39034840

RESUMEN

3D-printed shell complete dentures generated from a scan of the patient's existing prostheses can simplify and expedite the surgical planning and interim restoration design for complete arch rehabilitations. Three patients were rehabilitated with endosteal implants, and interim restorations were generated from the contours of the 3D-printed shell complete dentures used as diagnostic aids. This case series report presents the recommended protocol and its clinical progression, in addition to clinical and radiographic images of the treatment outcomes.

7.
J Prosthodont ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023016

RESUMEN

PURPOSE: The present study evaluated the effects of the root portion design, segment (middle vs. apical), and part (die vs. cast) on the trueness of three-dimensional (3D)-printed removable die-cast complex. MATERIAL AND METHODS: The trueness of apical and middle segments of the root portion of 45 3D-printed removable dies and casts with three different root portion designs (n = 15) was assessed using a metrology-grade computer program. The three removable dies and cast designs (root form [RF], conical [CON], and cylindric [CYL]) were created using professional computer-aided manufacturing computer programs (DentalCAD 3.1 Rijeka, and InLab CAD 22.0), and manufactured using stereolithographic 3D printer (Form3; FormLabs, Somerville, MA). Subsequently, the 3D-printed removable dies and casts were scanned by a single operator with an intraoral scanner (PrimeScan; Dentsply Sirona, Charlotte, NC), and their respective standard tessellation language files were aligned and compared to master reference files in a metrology-grade computer program (Geomagic Control X; 3D systems, Rock Hill, NC). The root mean square (RMS) values of the middle and apical segments for each removable die and cast were calculated and analyzed using a mixed model including a repeated measure 3-way analysis of variance (ANOVA) and post-hoc stepdown Bonferroni-corrected pairwise comparisons (α = 0.05). RESULTS: A statistically significant 3-way interaction between factors was detected, suggesting that the part (removable die or alveolar cast) and their design affected the RMS values of their apical and middle root portion segment. (p = 0.045). The post-hoc analysis identified significant differences between RMS values of the apical segments of the CON and CYL removable dies (p = 0.005). Significant differences were observed between the middle and apical segments of the CON (p < 0.001) and RF removable die designs (p = 0.004). No statistically significant differences were noticed between the RMS of the different alveolar cast designs (p > 0.05). Significant differences were detected between the apical and middle segments of the same alveolar cast design (p < 0.05). CONCLUSIONS: For the manufacturing trinomial and 3D printing strategy used in the present study, the interaction of the part, design, and segment affected the trueness of removable dies and alveolar casts. The trueness was higher on the middle segment on removable dies and alveolar casts in all designs used, except for CYL removable dies, where the trueness difference between segments was small. Higher trueness values may be achieved with designs with simple apical segment geometries.

9.
J Prosthodont ; 2024 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-38923252

RESUMEN

PURPOSE: To explore the impact of zirconia types, coloring methods, and surface finishing on the color stability of monolithic multilayered polychromatic zirconia after artificial aging, including thermocycling and simulated toothbrushing. MATERIALS AND METHODS: Eighty square-shaped zirconia samples were divided into 2 types (M3Y-TZP and M6Y-PSZ), further categorized based on coloring methods (precolored and extrinsically colored) and surface finishing techniques (mechanical polishing or glazing). The color stability was assessed using the CIEDE2000 formula. Artificial aging was simulated via thermocycling and toothbrushing. All samples were analyzed with a spectrophotometer to determine the post-aging color changes (ΔE00). The ΔE00 were interpreted and classified using the 50:50% perceptibility threshold (PT) and the 50:50% acceptability threshold (AT). Comparisons between groups for ΔE00 differences were performed using three-way ANOVA, with pairwise comparisons facilitated by Fisher's protected least significant difference test, α = 0.05. RESULTS: The study results indicated significant impacts of zirconia type, coloring method, and surface finishing on color stability. The M6Y groups experienced significantly greater color changes (6.61 ± 1.63) compared to the M3Y groups (3.40 ± 2.24), p < 0.0001. For both types of zirconia, extrinsically colored samples exhibited significantly higher ΔE00 when mechanically polished (p = 0.004). However, surface finishing had no significant effect on ΔE00 in precolored samples of either zirconia material (p = 1.000). The evaluation and categorization of ΔE00 variations indicated that nearly all color changes in the M6Y groups, regardless of being precolored, extrinsically colored, polished, or glazed, were deemed extremely unacceptable (Grade 1). In contrast, the M3Y groups showed more acceptable results, with the majority of color changes classified as moderately unacceptable (Grade 3). CONCLUSIONS: The color stability of multilayered polychromatic zirconia is influenced by the type of material, extrinsic coloring, and the chosen surface treatment post-artificial aging. The translucent 6Y-PSZ exhibited lower color stability, especially with only mechanical polishing. For the fabrication of M3Y-TZP and 6Y-PSZ monolithic multilayered polychromatic zirconia restorations, extrinsic coloring should be paired with glazing to maintain color stability. Conversely, in the absence of extrinsic coloring, both glazing and mechanical polishing are effective in preserving color stability.

10.
ACS Appl Mater Interfaces ; 16(27): 34819-34829, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38924763

RESUMEN

Sodium-ion batteries (SIBs) represent a promising energy storage technology with great safety. Because of their high operating potential, superior structural stability, and prominent thermal stability, polyanion-type phosphates have garnered significant interest in superior prospective cathode materials for SIBs. Nevertheless, the disadvantages of poor intrinsic electronic conductivity, sluggish kinetics, and volume variation during sodiation/desodiation remain great challenges for satisfactory rate performance and cycle stability, which severely hinder their further practical applications. In this work, by adjusting the amounts of pretreated multiwalled carbon nanotubes (CNT) added intentionally at the beginning of the preparation, biphasic polyanion-type phosphate materials (marked as NFC) are synthesized through a one-pot solid state reaction methodology, which are composed of CNT-interwoven Na3V2(PO4)2F3 (NVPF) and a small amount of Na3V2(PO4)3 (NVP). Benefiting from the improved electronic conductivity and unique composition and structure, the optimized sample (labeled as NFC-2) illustrates exceptional cycle stability and remarkable rate performance. The discharge capacities of the NFC-2 electrode are 114.8 and 78.6 mAh g-1 tested at 20 and 5000 mA g-1, respectively. Notably, such an electrode still gives out 75.7% capacity retention upon 10 000 cycles at 5000 mA g-1. In situ X-ray diffraction analysis demonstrates that the NFC-2 cathode has outstanding structural reversibility during charge/discharge cycles. More importantly, such a biphasic material has achieved impressive electrochemical performance within a wide operating temperature range of -20-50 °C. When temperature is decreased to -20 °C, the NFC-2 electrode still delivers an initial discharge capacity of 102.4 mAh g-1 and exhibits a remarkable capacity retention of 97.8% even after 500 cycles at 50 mA g-1. In addition, the sodium-ion full cell assembled by integrating NFC-2 cathode and hard carbon anode shows a satisfying energy density of 431.3 Wh kg-1 at 20 mA g-1 with a better long-term cycle performance. The synergistic effect among high energy NVPF, conductive CNT, and stable NVP may lead to the great improvement in the electrochemical sodium storage performance of the NFC-2 sample. Such biphasic polyanion-type phosphate materials will inject new ideas into the material design for SIBs with excellent electrochemical performance and further promote practical applications of this advanced energy storage technology.

11.
Orthop Nurs ; 43(3): 132-140, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38861742

RESUMEN

Mental health and housing status have the potential to impact total joint arthroplasty (TJA) outcomes and are common TJA eligibility criteria that prevent patients from receiving surgery. Our aim was to formulate recommendations for how nurse navigators can assist patients with managing mental health and housing concerns. Through discussions with nurse navigators and a literature search across two databases, we gathered information regarding the optimization of mental health and housing status among TJA patients. We observed a lack of standardized protocols for addressing these concerns and literature supporting an increased focus on mental health and housing status, indicating the potential for greater nurse navigator involvement in developing and implementing protocols. We recommend nurse navigators use screening tools to identify mental health and housing concerns and offer the suggested resources to support patients in an effort to improve postoperative outcomes and decrease surgical risks.


Asunto(s)
Navegación de Pacientes , Humanos , Vivienda/normas , Salud Mental , Enfermería Ortopédica , Artroplastia de Reemplazo
12.
Imeta ; 3(1): e165, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38868519

RESUMEN

Consumption of dietary fiber and anthocyanin has been linked to a lower incidence of colorectal cancer (CRC). This study scrutinizes the potential antitumorigenic attributes of a black rice diet (BRD), abundantly rich in dietary fiber and anthocyanin. Our results demonstrate notable antitumorigenic effects in mice on BRD, indicated by a reduction in both the size and number of intestinal tumors and a consequent extension in life span, compared to control diet-fed counterparts. Furthermore, fecal transplants from BRD-fed mice to germ-free mice led to a decrease in colonic cell proliferation, coupled with maintained integrity of the intestinal barrier. The BRD was associated with significant shifts in gut microbiota composition, specifically an augmentation in probiotic strains Bacteroides uniformis and Lactobacillus. Noteworthy changes in gut metabolites were also documented, including the upregulation of indole-3-lactic acid and indole. These metabolites have been identified to stimulate the intestinal aryl hydrocarbon receptor pathway, inhibiting CRC cell proliferation and colorectal tumorigenesis. In summary, these findings propose that a BRD may modulate the progression of intestinal tumors by fostering protective gut microbiota and metabolite profiles. The study accentuates the potential health advantages of whole-grain foods, emphasizing the potential utility of black rice in promoting health.

13.
Front Microbiol ; 15: 1358752, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38873147

RESUMEN

Candida albicans (C. albicans), a microbe commonly isolated from Candida vaginitis patients with vaginal tract infections, transforms from yeast to hyphae and produces many toxins, adhesins, and invasins, as well as C. albicans biofilms resistant to antifungal antibiotic treatment. Effective agents against this pathogen are urgently needed. Antimicrobial peptides (AMPs) have been used to cure inflammation and infectious diseases. In this study, we isolated whole housefly larvae insect SVWC peptide 1 (WHIS1), a novel insect single von Willebrand factor C-domain protein (SVWC) peptide from whole housefly larvae. The expression pattern of WHIS1 showed a response to the stimulation of C. albicans. In contrast to other SVWC members, which function as antiviral peptides, interferon (IFN) analogs or pathogen recognition receptors (PRRs), which are the prokaryotically expressed MdWHIS1 protein, inhibit the growth of C. albicans. Eukaryotic heterologous expression of WHIS1 inhibited C. albicans invasion into A549 and HeLa cells. The heterologous expression of WHIS1 clearly inhibited hyphal formation both extracellularly and intracellularly. Furthermore, the mechanism of WHIS1 has demonstrated that it downregulates all key hyphal formation factors (ALS1, ALS3, ALS5, ECE1, HWP1, HGC1, EFG1, and ZAP1) both extracellularly and intracellularly. These data showed that heterologously expressed WHIS1 inhibits C. albicans invasion into epithelial cells by affecting hyphal formation and adhesion factor-related gene expression. These findings provide new potential drug candidates for treating C. albicans infection.

14.
J Prosthodont ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38742795

RESUMEN

PURPOSE: To examine the color stability of 3D-printed and milled, interim, and definitive, restorative materials after immersion in artificial saliva and wine for 1, 3, and 6 months. MATERIAL AND METHODS: The study used a 2 × 5 factorial design with 10 subgroups, including 2 immersion liquids (artificial saliva and wine) and 5 manufacturing technology and restorative material combinations (n = 10). Color measurements were taken using a contact-type digital spectrophotometer (CM-2600d Spectrophotometer; Konica Minolta Healthcare Americas Inc) before immersion and at 1 month (T1), 3 months (T3), and 6 months (T6) after immersion. The CIE2000 system was used to calculate quantitative measurements of color differences in ΔE00, and comparisons were made to the acceptability threshold (AT) and perceptibility threshold (PT). Repeated measures of ANOVA (α = 0.05) were used to compare differences in color changes between manufacturing technology/restorative material-immersion liquid combinations at T1, T3, and T6. RESULTS: To compare the effect of immersion liquid and time on the manufacturing technology/restorative material groups, the ΔE00 values were compared to the PT of 0.8 and the AT of 1.8. Wine caused significant color changes in ΔE00 values beyond the PT and AT values in all groups at all time intervals, except for the AT value of milled definitive crowns (hybrid nano-ceramic material). Wine immersion caused significant ΔE00 for all manufacturing technology/restorative material groups at all time intervals (1 month, 3 months, and 6 months) when compared to artificial saliva immersion (all p < 0.001). CONCLUSION: Upon exposure to artificial saliva, 80%-100% of samples from all groups remained within the acceptable and perceptible color change thresholds. The wine had significant chromogenic effects on all tested restorative materials, however, the milled definitive crowns (hybrid nano-ceramic material) showed the greatest color stability. For patients with heavy wine consumption, 3D-printed definitive crowns (hybrid ceramic-filled material) may show discoloration exceeding acceptable and perceptible color change limits.

15.
J Am Chem Soc ; 146(19): 12901-12906, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38701349

RESUMEN

Cholesterol-rich membranes play a pivotal role in cancer initiation and progression, necessitating innovative approaches to target these membranes for cancer inhibition. Here we report the first case of unnatural peptide (1) assemblies capable of depleting cholesterol and inhibiting cancer cells. Peptide 1 self-assembles into micelles and is rapidly taken up by cancer cells, especially when combined with an acute cholesterol-depleting agent (MßCD). Click chemistry has confirmed that 1 depletes cell membrane cholesterol. It localizes in membrane-rich organelles, including the endoplasmic reticulum, Golgi apparatus, and lysosomes. Furthermore, 1 potently inhibits malignant cancer cells, working synergistically with cholesterol-lowering agents. Control experiments have confirmed that C-terminal capping and unnatural amino acid residues (i.e., BiP) are essential for both cholesterol depletion and potent cancer cell inhibition. This work highlights unnatural peptide assemblies as a promising platform for targeting the cell membrane in controlling cell fates.


Asunto(s)
Colesterol , Péptidos , Humanos , Colesterol/química , Colesterol/metabolismo , Péptidos/química , Péptidos/farmacología , Antineoplásicos/farmacología , Antineoplásicos/química , Antineoplásicos/síntesis química , Línea Celular Tumoral , Membrana Celular/efectos de los fármacos , Membrana Celular/metabolismo , Proliferación Celular/efectos de los fármacos
16.
Int Orthop ; 48(9): 2403-2410, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38767711

RESUMEN

PURPOSE: Concurrent use of minus heads with tapered stems in total hip arthroplasty (THA) decreases the prosthetic range of motion (pROM). Three-dimensional preoperative templating can simulate the location of the impingement by taking the hip through a virtual pROM. This enables surgeons to simulate how modifying the type of implant, orientation, and position influences impingement. We hypothesized that CT-based modeling would result in a decrease in the pROM, thereby increasing the risk of impingement when minus heads are used. METHODS: Forty-three patients who underwent robotic-assisted primary THAs were included. Prosthetic head diameter (32/36-mm) and head length (minus/zero/plus) were the predictors. Maximum external rotation at full hip extension and internal rotation at 90° and 100° of flexion prior to prosthetic impingement were the outcome variables. A CT-based preoperative planning software was used for pROM estimation and impingement detection. RESULTS: Significant decreases in pROM were found for both head diameters as the head length decreased and was more pronounced in external rotation during full hip extension (changes of 2.8-3.4° for the 32-mm head and 1.6-2.8° for the 36-mm head (p = 0.00011)). The magnitude of loss in pROM when using a minus head was larger than the gain provided by a plus head in tapered stems (p < 0.0001). CONCLUSION: Head length affects the offset and pROM. When the use of minus heads or smaller heads is indicated, 3D preoperative templating for assessing postoperative pROM and impingement provides surgeons with options to consider alternate surgical plans offering additional assurance and protection from dislocation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera , Prótesis de Cadera , Imagenología Tridimensional , Diseño de Prótesis , Rango del Movimiento Articular , Programas Informáticos , Tomografía Computarizada por Rayos X , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Masculino , Femenino , Rango del Movimiento Articular/fisiología , Persona de Mediana Edad , Anciano , Imagenología Tridimensional/métodos , Articulación de la Cadera/cirugía , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/diagnóstico por imagen , Procedimientos Quirúrgicos Robotizados/métodos , Cuidados Preoperatorios/métodos
17.
J Prosthodont ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38706414

RESUMEN

PURPOSE: To evaluate the effects of two base types and three restoration designs on the resin consumption and trueness of the 3D-printed dental casts. Additionally, the study explored the dimensional stability of these 3D-printed dental casts after 1 year of storage. MATERIALS AND METHODS: Various types of reference dental casts were specifically designed to represent three types of dental restoration fabrications, including full-arch (FA), long-span (LS), and single-unit (SU) prostheses. The reference casts were digitized with a dental laboratory scanner and used to create flat and hollow base designs (N = 18) for the 3D-printed study casts. The 3D-printed study casts were digitized and evaluated against their corresponding references immediately after 3D printing and again after 1 year of storage, with the trueness quantified using the root mean square error (RMSE) at both time points. Volumes of resin used were recorded to measure resin consumption, and the weights of the 3D-printed study casts were also measured. The data were analyzed using two-way ANOVA and a Tukey post hoc test, α = 0.05. RESULTS: Volumetric analysis showed the flat-base design had significantly higher resin consumption with weights for the FA group at 42.51 ± 0.16 g, the LS group at 31.64 ± 0.07 g, and the SU group at 27.67 ± 0.31 g, as opposed to 26.22 ± 1.01 g, 22.86 ± 0.93 g, and 20.10 ± 0.19 g for the hollow designs respectively (p < 0.001). Trueness, assessed through two-way ANOVA, revealed that the flat-base design had lower RMSE values indicating better trueness in the LS (54 ± 6 µm) and SU (59 ± 7 µm) groups compared to the hollow-base design (LS: 73 ± 5, SU: 99 ± 11 µm, both p < 0.001), with no significant difference in the FA group (flat-base: 50 ± 3, hollow: 47 ± 5 µm, p = 0.398). After 1 year, the flat-base design demonstrated superior dimensional stability in the LS (flat base: 56 ± 6 µm, hollow base: 149 ±45 µm, p < 0.001) and SU groups (flat base: 95 ± 8 µm, hollow base: 183 ±27 µm, p < 0.001), with the FA group showing no significant difference in the base design (flat base: 47 ± 9, hollow base: 62 ± 12 µm, p = 0.428). CONCLUSIONS: The hollow-base design group showed lower resin consumption than the flat-base design group. However, the flat-base designs exhibited superior trueness and less distortion after 1 year of storage. These findings indicate that despite the higher material usage, flat-base designs provide better initial accuracy and maintain their dimensional stability over time for most groups.

18.
J Prosthodont ; 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600720

RESUMEN

Traditionally, artificial teeth arrangements or the definitive complete dentures are used to establish important prosthodontic parameters such as the occlusal plane orientation, vertical dimension, and the incisal edge position. The relationship of these elements with the underlying bony structures is commonly evaluated using advanced planning protocols such as the dual scan technique. This technique article presents an uncomplicated alternative approach to establish these parameters intraorally using a 3D-printed shell complete denture generated from a 3D scan of the patient's existing complete denture.

19.
Front Oncol ; 14: 1372123, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38628666

RESUMEN

Background: Portal vein tumor thrombus (PVTT) seriously affects the prognosis of hepatocellular carcinoma (HCC). However, whether bile duct tumor thrombus (BDTT) significantly affects the prognosis of HCC as much as PVTT remains unclear. We aimed to compare the long-term surgical outcomes of HCC with macroscopic PVTT (macro-PVTT) and macroscopic BDTT (macro-BDTT). Methods: The data of HCC patients with macro-BDTT or macro-PVTT who underwent hemihepatectomy were retrospectively reviewed. A propensity score matching (PSM) analysis was performed to reduce the baseline imbalance. The recurrence-free survival (RFS) and overall survival (OS) rates were compared between the cohorts. Results: Before PSM, the PVTT group had worse RFS and OS rates than the BDTT group (P = 0.043 and P = 0.008, respectively). Multivariate analyses identified PVTT (hazard ratio [HR] = 1.835, P = 0.016) and large HCC (HR = 1.553, P = 0.039) as independent risk factors for poor OS and RFS, respectively. After PSM, the PVTT group had worse RFS and OS rates than the BDTT group (P = 0.037 and P = 0.004, respectively). The 3- and 5-year OS rates were significantly higher in the BDTT group (59.5% and 52.1%, respectively) than in the PVTT group (33.3% and 20.2%, respectively). Conclusion: Aggressive hemihepatectomy provides an acceptable prognosis for HCC patients with macro-BDTT. Furthermore, the long-term surgical outcomes of HCC patients with macro-BDTT were significantly better than those of HCC patients with macro-PVTT.

20.
J Prosthodont ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38666691

RESUMEN

PURPOSE: This systematic review aims to compare clinical outcomes of digital dentures with conventional dentures. MATERIALS AND METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in Prospero. The formulated population, intervention, comparison, outcome (PICO) question was "What is the clinical outcome of digital versus conventional complete dentures (CDs) in edentulous patients?". The search strategy used three main electronic databases and an additional manual search was completed in August 2023 by following an established search strategy. Initial inclusion was based on titles and abstracts, followed by a detailed review of selected studies, and clinical studies that evaluated the clinical outcome of digital (milled or 3D-printed) versus conventional CDs were included. A qualitative analysis for clinical studies was used to assess the risk of bias. The certainty of the evidence was assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) system. In addition, a single-arm meta-analysis was performed to evaluate the retention between digital versus conventional CDs. RESULTS: The initial search yielded a total of 947 articles, out of which 19 were selected for a comprehensive review, and six met the eligibility criteria to be included in this systematic review. The computer-aided design and computer-aided manufacturing (CAD-CAM) CDs showed increased retention, no relevant differences in oral health-related quality of life (OHRQoL), and shorter working time compared to conventional dentures. Two studies were eligible for meta-analysis; retention was significantly better among CAD-CAM fabricated dentures (standardized mean difference [SMD] 0.501) than conventional dentures. The heterogeneity between studies was high (95% CI: 0.049-0.952). CONCLUSIONS: Clinically, both the milled and the 3D-printed CD fared better than conventional dentures in terms of retention, reduction in the number of appointments, improved patient comfort, and improved predictable maintenance of the denture. Patients' perceptions and satisfaction were independent of the digital and conventional fabricated dentures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA