Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Lancet ; 390(10108): 2160-2170, 2017 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-28859944

RESUMEN

BACKGROUND: Previous randomised renal denervation studies did not show consistent efficacy in reducing blood pressure. The objective of our study was to evaluate the effect of renal denervation on blood pressure in the absence of antihypertensive medications. METHODS: SPYRAL HTN-OFF MED was a multicentre, international, single-blind, randomised, sham-controlled, proof-of-concept trial. Patients were enrolled at 21 centres in the USA, Europe, Japan, and Australia. Eligible patients were drug-naive or discontinued their antihypertensive medications. Patients with an office systolic blood pressure (SBP) of 150 mm Hg or greater and less than 180 mm Hg, office diastolic blood pressure (DBP) of 90 mm Hg or greater, and a mean 24-h ambulatory SBP of 140 mm Hg or greater and less than 170 mm Hg at second screening underwent renal angiography and were randomly assigned to renal denervation or sham control. Patients, caregivers, and those assessing blood pressure were blinded to randomisation assignments. The primary endpoint, change in 24-h blood pressure at 3 months, was compared between groups. Drug surveillance was done to ensure patient compliance with absence of antihypertensive medication. The primary analysis was done in the intention-to-treat population. Safety events were assessed at 3 months. This study is registered with ClinicalTrials.gov, number NCT02439749. FINDINGS: Between June 25, 2015, and Jan 30, 2017, 353 patients were screened. 80 patients were randomly assigned to renal denervation (n=38) or sham control (n=42) and followed up for 3 months. Office and 24-h ambulatory blood pressure decreased significantly from baseline to 3 months in the renal denervation group: 24-h SBP -5·5 mm Hg (95% CI -9·1 to -2·0; p=0·0031), 24-h DBP -4·8 mm Hg (-7·0 to -2·6; p<0·0001), office SBP -10·0 mm Hg (-15·1 to -4·9; p=0·0004), and office DBP -5·3 mm Hg (-7·8 to -2·7; p=0·0002). No significant changes were seen in the sham-control group: 24-h SBP -0·5 mm Hg (95% CI -3·9 to 2·9; p=0·7644), 24-h DBP -0·4 mm Hg (-2·2 to 1·4; p=0·6448), office SBP -2·3 mm Hg (-6·1 to 1·6; p=0·2381), and office DBP -0·3 mm Hg (-2·9 to 2·2; p=0·8052). The mean difference between the groups favoured renal denervation for 3-month change in both office and 24-h blood pressure from baseline: 24-h SBP -5·0 mm Hg (95% CI -9·9 to -0·2; p=0·0414), 24-h DBP -4·4 mm Hg (-7·2 to -1·6; p=0·0024), office SBP -7·7 mm Hg (-14·0 to -1·5; p=0·0155), and office DBP -4·9 mm Hg (-8·5 to -1·4; p=0·0077). Baseline-adjusted analyses showed similar findings. There were no major adverse events in either group. INTERPRETATION: Results from SPYRAL HTN-OFF MED provide biological proof of principle for the blood-pressure-lowering efficacy of renal denervation. FUNDING: Medtronic.


Asunto(s)
Ablación por Catéter/métodos , Resistencia a Medicamentos , Hipertensión/cirugía , Simpatectomía/métodos , Adulto , Factores de Edad , Anciano , Antihipertensivos/uso terapéutico , Australia , Determinación de la Presión Sanguínea , Europa (Continente) , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/tratamiento farmacológico , Internacionalidad , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Pronóstico , Valores de Referencia , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Método Simple Ciego , Resultado del Tratamiento , Estados Unidos
3.
Ann Vasc Surg ; 43: 311.e5-311.e7, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28478167

RESUMEN

We report the case of a 74-year-old male with an incidental finding of a pseudoaneurysm at the base of his neck arising from the left subclavian artery. Initial treatment with ultrasound-guided thrombin injection was unfortunately unsuccessful with early recanalization. An Amplatzer Vascular Plug 4 device was introduced into the neck of the pseudoaneurysm endovascularly with successful thrombosis and occlusion of the pseudoaneurysm.


Asunto(s)
Aneurisma Falso/terapia , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Arteria Subclavia , Anciano , Aneurisma Falso/diagnóstico por imagen , Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Diseño de Equipo , Humanos , Hallazgos Incidentales , Masculino , Arteria Subclavia/diagnóstico por imagen , Resultado del Tratamiento
4.
Cardiovasc Intervent Radiol ; 34(6): 1143-50, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21331454

RESUMEN

Uterine leiomyomata, or fibroids, although benign, cause debilitating symptoms in many women. Symptoms are often nonspecific and may be the presenting complaint in a number of other conditions. Furthermore, because the presence of fibroids may be coincident with other symptomatic conditions that result in similar complaints, there may be diagnostic difficulty and consequent difficulty in planning therapeutic strategy. Uterine artery embolization (UAE) is a safe and effective treatment for symptomatic fibroids and is increasingly being performed. Magnetic resonance imaging (MRI) evaluation before and after treatment is routine practice with the potential to significantly alter management in up to a fifth of patients. It is well recognized that significant incidental findings may be demonstrated during imaging investigations, and in particular that abnormalities that are not directly related to the clinical question may be overlooked. Radiologists evaluating pre-UAE MRI studies must be aware of the MRI appearances of gynecological pathologies that may cause similar symptoms or that may affect the success or complication rates of UAE, and they must also be wary of "satisfaction of search," reviewing imaging thoroughly so that relevant other pathologies are not missed. We demonstrate the appearances of coincidental pathologies found on pre-UAE MRI, with the potential to change patient management.


Asunto(s)
Imagen por Resonancia Magnética , Embolización de la Arteria Uterina/métodos , Enfermedades Uterinas/diagnóstico , Enfermedades Uterinas/terapia , Dolor de Espalda/diagnóstico , Quistes/diagnóstico , Quistes/terapia , Diagnóstico Diferencial , Endometriosis/diagnóstico , Endometriosis/terapia , Femenino , Humanos , Enfermedades Intestinales/diagnóstico , Enfermedades Intestinales/terapia , Leiomioma/diagnóstico , Leiomioma/terapia , Estadificación de Neoplasias , Enfermedades Urológicas/diagnóstico , Enfermedades Urológicas/terapia , Neoplasias Uterinas/diagnóstico , Neoplasias Uterinas/terapia
5.
J Vasc Interv Radiol ; 21(4): 590-2, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20149689

RESUMEN

Gastric outlet obstruction is a well- recognized complication of locally advanced carcinoma of the head of the pancreas. The authors report a transoral placement of a duodenal stent over a percutaneous guide wire, inserted retrogradely through a transhepatic approach via the ampulla of Vater, in a patient in whom traditional stent placement was technically not possible. This technique allows safe duodenal stent placement for different malignant gastric outlet obstruction such as pancreatic, gastric, duodenal, and metastases to the peripancreatic region.


Asunto(s)
Obstrucción de la Salida Gástrica/etiología , Obstrucción de la Salida Gástrica/terapia , Hígado/cirugía , Boca , Neoplasias Pancreáticas/complicaciones , Implantación de Prótesis/métodos , Stents , Anciano , Duodeno , Femenino , Obstrucción de la Salida Gástrica/diagnóstico por imagen , Humanos , Hígado/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Radiografía , Resultado del Tratamiento
7.
Future Oncol ; 4(1): 103-11, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18241005

RESUMEN

Development of cross-sectional imaging has led to a significant increase in diagnosis of small renal tumors. Nephron-sparing surgery has proven to be effective in the management of these small tumors. Could radiofrequency ablation be as effective in the management of these patients, after showing promising results in a selected group of patients? In this article we discuss the principles of radiofrequency ablation and present results in a selected group of patients. We also outline future perspectives of this noninvasive technique.


Asunto(s)
Carcinoma de Células Renales/terapia , Ablación por Catéter , Neoplasias Renales/terapia , Carcinoma de Células Renales/patología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Humanos , Neoplasias Renales/patología , Selección de Paciente , Terapia Asistida por Computador , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
8.
Radiology ; 237(2): 718-26, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16192318

RESUMEN

PURPOSE: To prospectively evaluate the safety and effectiveness of hepatic intraarterial injection of yttrium 90 ((90)Y) tetraazacyclododecane tetraacetic acid (DOTA) lanreotide as a treatment for patients with progressive large-volume somatostatin receptor-positive liver metastases from neuroendocrine tumors. MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave informed consent. Twenty-three patients (13 men, 10 women; age range, 21-69 years; median age, 57 years) with histologically proved large-volume liver metastases from neuroendocrine cancers were treated. All patients had radiologic evidence of liver disease progression and high uptake of indium 111 ((111)In) pentetreotide at scintigraphy. Selective hepatic intraarterial injection of (90)Y-DOTA-lanreotide (total of 36 treatments; median activity per dose, 1 GBq) was administered with or without embolization. Treatment cycles were performed in 8-week intervals. Clinical, biologic, and radiologic tumor responses were assessed 8-12 weeks after each treatment cycle. Objective tumor response was classified according to World Health Organization response criteria as complete regression, partial response, stable disease, or disease progression. Kaplan-Meier survival curves were used to calculate 1-year survivals. RESULTS: Partial response to treatment was achieved in three (16%) of 19 patients, and stable disease was achieved in 12 (63%). Four (21%) of 19 patients had continued disease progression. Clinical improvement was reported by 14 (61%) of the 23 patients, and a reduction in biologic marker levels was observed in nine (60%) of 15 patients. Reversible hematologic toxicity (National Cancer Institute common toxicity criteria grade > 2) occurred in three patients. The 1-year survival rate was 63% (median survival time, 15 months). CONCLUSION: Hepatic intraarterial injection of (90)Y-DOTA-lanreotide is a safe and effective palliative treatment for patients with progressive large-volume somatostatin receptor-positive liver metastases from neuroendocrine tumors.


Asunto(s)
Compuestos Heterocíclicos/uso terapéutico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Tumores Neuroendocrinos/patología , Cuidados Paliativos , Péptidos Cíclicos/uso terapéutico , Radiofármacos/uso terapéutico , Adulto , Anciano , Femenino , Arteria Hepática , Compuestos Heterocíclicos/administración & dosificación , Humanos , Inyecciones Intraarteriales , Masculino , Persona de Mediana Edad , Péptidos Cíclicos/administración & dosificación , Estudios Prospectivos , Cintigrafía , Radiofármacos/administración & dosificación , Tasa de Supervivencia , Resultado del Tratamiento
9.
Dig Surg ; 21(2): 152-9; discussion 159-60, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15166485

RESUMEN

BACKGROUND: In recent years, liver transplantation in patients with hepatocellular cancers and cirrhosis has been restricted to those with small cancers (<5 cm for solitary and <3 cm for multifocal HCC with <3 nodules). The selection of patients for liver transplantation is based on pre-operative imaging. The accuracy of imaging correlated with explant histology and the effect of tumour stage has not been evaluated in this selected population. METHODS: In this study, prospectively collected data for 30 patients who underwent orthotopic liver transplantation for cirrhosis complicated by small hepatocellular carcinoma (HCC) at a single centre have been reviewed with the aim of correlating radiological findings, explant histology and patient outcome. Patients who underwent orthotopic liver transplantation between 1995 and 1999 had plain and contrast-enhanced dual-phase spiral CT (DCT) scans of the liver. Patients suspected of having HCC on CT scan or due to elevated serum alpha-fetoprotein underwent iodized oil CT (IOCT). Following transplantation, the explanted liver was serially sectioned at 10-mm intervals and examined by a pathologist blinded to the results of imaging. Data collected prospectively on imaging and histology were compared with outcome data. The median period of follow-up was 1,139 days (range 690-1,955 days) after transplantation. All patients were followed up by clinical assessment, assessment of serum alpha-protein levels and imaging when indicated. RESULTS: All the patients transplanted fulfilled the selective criteria on the basis of imaging (solitary HCC <5 cm in diameter or multifocal HCC <3 cm in diameter with <3 nodules). Of the 30 patients transplanted, 46 HCCs were detected on explant histology with a median size of 24 mm (range 6-75 mm). Ten patients had multifocal disease (median number of lesions 2, range 2-4). No significant difference was observed between IOCT and DCT with regards to the sensitivity (67.4 vs. 68%) and specificity (78.97 vs. 88.6%) of detecting HCCs. IOCT had a positive predictive value of 78.9% as compared to 82.8% for DCT. IOCT had an overall sensitivity of 40% as compared to 30% for DCT in detecting multifocal disease (not significant). Histological assessment of the explanted livers showed that 8 patients had well-, 17 moderate and 5 poorly differentiated HCCs. Tumour size and the presence of multifocal disease did not influence survival in this study. Microvascular invasion was more common with larger tumours (from 38% with lesions less than 40 mm in diameter to 60% with lesions >40 mm in diameter; p < 0.01) and with moderately (29.4%) or poorly differentiated (60%) HCCs than well-differentiated HCC (12.5%) (p < 0.04 and 0.01 for well- vs. moderately and poorly differentiated HCC, respectively). Microvascular invasion on explant histology was associated with poor survival. Of the 17 transplant recipients without vascular invasion, 15 were alive at 1 and 2 years in comparison to 7 of 9 with microscopic vascular invasion (p < 0.01). Four patients died in the post-transplant period due to recurrent HCC. Overall survival [after excluding early post-transplant sepsis-induced deaths (n = 4)] at 1 year was 83.3%. CONCLUSIONS: Selective criteria for transplantation of HCC in cirrhosis are associated with a 1-year and 3-year survival rate of 73.3% (including early post-transplant sepsis-induced deaths). IOCT and DCT are similar in their ability to detect unifocal or multifocal HCC. Tumour size and number are not predictive of recurrence with these selective criteria, but microscopic vascular invasion is a bad prognostic factor.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Neoplasias Hepáticas/cirugía , Trasplante de Hígado/mortalidad , Tomografía Computarizada por Rayos X/métodos , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/cirugía , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Estadificación de Neoplasias , Selección de Paciente , Valor Predictivo de las Pruebas , Cuidados Preoperatorios , Pronóstico , Estudios Retrospectivos , Análisis de Supervivencia , Resultado del Tratamiento
10.
Med Sci Monit ; 10 Suppl 3: 9-16, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16538192

RESUMEN

BACKGROUND: Functional and anatomical imaging methods are currently the standard approach to the evaluation of carcinoid tumor extent. Due to the nature of carcinoid tumors ,there is not a single imaging procedure that is sufficient to detect the malignancy. The aim of the study was to compare the value of CT, MR and functional imaging study with(111) In-Octreotide (SRS) in carcinoid detection and evaluation of its extent as well as to work out the imaging studies diagnostic algorithm that could enhance diagnostic efficacy. MATERIAL/METHODS: A total of 34 patients with carcinoid tumor confirmed clinically,biochemically and/or histopathologically were enrolled into the study. Computed tomography (CT) examinations of the abdomen and pelvis were performed before and after administration of a contrast medium, the triple-phase liver scanning included. Magnetic Resonance Imaging (MRI)of the liver was performed according to the standardized protocol before and after administration of a contrast medium .Planar scintigraphy with(111) In Octreotide and SPECT were performed. In each case liver as well as lymph node metastases in the abdomen and pelvis were searched for. All results were reviewed independently. Clinical picture at follow-up and further imaging and/or histological studies confirmed or excluded the diagnosis of the disease. RESULTS: Twenty nine patients were diagnosed with carcinoid tumor. Liver metastases were found in 26 patients and lymph node metastases were detected in 18 of them. Complete diagnostic conformity as far as the diagnosis and extent of the disease are concerned was obtained only in 7 cases. Incorrect assessment of the disease extent was the source of discrepancy between the imaging studies results in most of the remaining 22 patients. The SRS and MR results of liver metastases detection were mostly consistent with one another. Both imaging modalities evaluated the extent of hepatic metastases incorrectly in 22%of the patients,as compared to 43% of the patients for CT. The highest proportion percentages of incorrect results of lymphatic involvement detection were 41%, 29%and 43%for MR, SRS and CT, respectively. CONCLUSIONS: The results of our study have indicated that application of a complex imaging algorithm enables higher accuracy of hepatic and lymph nodes metastases detection in carcinoid tumor patients. Combining the results of MR and SRS in evaluating the extent of the carcinoid disease seems to represent higher diagnostic value than relying on one of this method in combination with CT images.


Asunto(s)
Tumor Carcinoide/diagnóstico , Adolescente , Adulto , Anciano , Algoritmos , Tumor Carcinoide/diagnóstico por imagen , Tumor Carcinoide/secundario , Medios de Contraste , Errores Diagnósticos , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundario , Metástasis Linfática/diagnóstico , Imagen por Resonancia Magnética , Masculino , Síndrome Carcinoide Maligno/diagnóstico , Persona de Mediana Edad , Octreótido/análogos & derivados , Radiofármacos , Estudios Retrospectivos , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA