1.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-265611

RESUMEN

To assure the clinical quality and requirement of CT shelter used in field environment, the factors related with the practical application were studied. The evaluation indicators of CT equipment were investigated. Based on the technical modification of vehicle shelter CT, the scanning conditions of shelter CT were analyzed. Moreover, the comparative study was done between shelter CT and common CT in hospitals. In result, in order to meet maneuverability application in the field, vehicle shelter CT was restrictive by the field conditions, traffic impacts and running requirement. The application of vehicle shelter CT was affected by the factors, such as mechanical stabilization, moving precision, power fluctuations and variations of temperature and humidity, etc. The results were helpful to improve the clinical quality of vehicle shelter CT and made a base for the quality control study in the future.


Asunto(s)
Humedad , Temperatura , Tomografía Computarizada por Rayos X
2.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-259952

RESUMEN

To improve the usage rate and quality of emergency equipment in the hospital, the emergency equipment management was studied. The specialized management and common use of emergency equipment in a hospital was analysed with statistical methods. The usage rate, economic effectiveness and management quality of the equipment were evaluated. Based on the practical experience, the superiorities of the specialized management and common use of emergency equipment in hospitals were summarized, and the inferior positions and their improvement approaches were proposed. As a result, the hospital resource allocation was optimized and the equipment management level was improved by using the specialized management and common use of emergency equipment in the hospital.


Asunto(s)
Servicio de Urgencia en Hospital , Administración de Materiales de Hospital
3.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-325949

RESUMEN

Three algorithms of electrical impedance tomography (EIT) are studied in this paper. The image resolution, anti-noise property and computation rapidity of the reconstruction algorithms are compared. As a result, it shows that back-projection algorithm has good anti-noise property, that NOSER algorithm generates images with good resolution, and that sensitivity matrix algorithm has moderate property.


Asunto(s)
Algoritmos , Impedancia Eléctrica , Procesamiento de Imagen Asistido por Computador , Métodos
4.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-330462

RESUMEN

Clinical experiments are always used to evaluate the safety and validity of medical devices. The experiments have two types of clinical trying and testing. Ethic review must be done by the ethics committee of the medical department with the qualification of clinical research, and the approval must be made before the experiments. In order to ensure the safety and validity of clinical experiments of medical devices in medical institutions, the contents, process and approval criterions of the ethic review were analyzed and discussed.


Asunto(s)
Humanos , Investigación Biomédica , Ética , Equipos y Suministros , Ética , Revisión Ética
5.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-404623

RESUMEN

To improve the accuracy of finite element method used in medicine field, it is necessary to build the finite element model including real structural information of tissues in human body. In this study, an edge extracting method was introduced on CT image of human body, and the method of building the two-dimensional finite element model from the extracted edges was then raised. Using the above methods, a finite element model of human body containing real structural information can be successfully made. The methods were used for many CT images of hospitals and tested to be simple, fast and adaptable. The study makes a good foundation for further finite element analysis based on medicine images.

6.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-318122

RESUMEN

Piglets having each a body weight of 20-30 kg and an abdominal perimeter like human's were used in the experiment. Being guided by ultrasound, we stabbed the piglet's abdomen, placed a catheter on the liver's lower margin, then injected the anticoagulated blood through the catheter by electrical infusion pump with constant speed respectively, and monitored the whole process by EIT. We observed the image change, using Ultrasound and CT to examine the area of blood injection after the end of monitoring,and we dissected to check the result of observations. The results reveal: (1) Ultrasound, CT and dissection are all able to find out a large amount of blood in piglet's abdominal cavity; (2) The pixel value of EIT target area decreases with the increase of blood, and the change in impedance image can be obviously observed. Therefore, this animal model is suitable for simulating intraperitoneal bleeding, and the speed of bleeding therein can be controlled. We can get a limpid image when EIT is used for monitoring the intraperitoneal bleeding simulated by this animal model.


Asunto(s)
Animales , Femenino , Masculino , Impedancia Eléctrica , Hemorragia , Diagnóstico , Interpretación de Imagen Asistida por Computador , Métodos , Monitoreo Fisiológico , Métodos , Enfermedades Peritoneales , Diagnóstico , Pletismografía de Impedancia , Métodos , Porcinos , Tomografía , Métodos
7.
Chinese Journal of Trauma ; (12): 271-274, 2009.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-395764

RESUMEN

Objective To apply electrical impedance tnmography that is a new evaluation ap-proach to monitor the development of retroperitoneal injury. We used retroperitoneal inject blood model in pigs to study the feasibility on monitoring retroperitoneal bleeding and to provide premise in theory and practice for clinical application. Methods Five pigs were used on the experiment. We insert a vessel into the retroperitoneal and inject blood to simulate retroperitoneal bleeding. Sixteen electrodes were atta-ched on the abdominal region circumference of pigs and used for electrical current injection and surface voltage measurement. Then the monitoring images were performed by electrical impedance tomography. Results The images of electrical impedance tomography retroperitoneal inject blood model of five pigs were clear, the minimal impedance scale was decreasing significantly as the bleeding volume increasing and the images were changed significantly too. The computerized tomography and the dissecting results confirmed the blood was limited in retroperitoneal. Conclusions The establishments of pigs retroper-itoneal inject blood model was successful. The images of electrical impedance tomography retroperitoneal inject blood model were clear with significant contrast. It's feasible to use electrical impedance tomography system to monitor the retroperitoneal bleeding. This technique may become a useful tool for monitoring ret-roperitoneal injury in intensive care patients.

8.
Physiol Meas ; 29(2): 217-25, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18256453

RESUMEN

Current medical imaging techniques are not effective for timely detection of internal hemorrhage when the bleeding is slow and in small quantities. In this study, electrical impedance tomography (EIT) was applied to monitor the intraperitoneal bleeding of an animal model. Five healthy pigs three months old were used. The process of intraperitoneal bleeding was simulated with the injection of anticoagulated blood which was controlled by an electronic syringe pump. The injected rate was no more than 100 ml h(-1) and the total injection volumes ranged from 300 ml to 500 ml. Sixteen electrodes were attached to the abdomen and used for electrical current excitation and surface voltage measurement. Dynamic changes in impedance distribution within the abdomen were calculated by the back-projection algorithm and a series of EIT images were displayed in a unified range. The monitoring was performed with EIT at a rate of one frame per second and continued for at least 4 h. Intraperitoneal blood volume changes could be identified by inspection of consecutive EIT images during the progression of blood injection. 30 ml of blood in the peritoneum could be detected. EIT was shown to be a promising technique for continuous monitoring of intraperitoneal bleeding over periods of time.


Asunto(s)
Impedancia Eléctrica , Hemorragia/diagnóstico , Interpretación de Imagen Asistida por Computador/métodos , Monitoreo Fisiológico/métodos , Enfermedades Peritoneales/diagnóstico , Tomografía/métodos , Animales , Porcinos
9.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 1500-3, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-17282485

RESUMEN

An image monitoring system using electrical impedance tomography (EIT) for intraperitoneal bleeding was designed (FMMU V3.5). It consists of a constant current driving source with frequency of 50 KHz, a high accuracy measurement module, a driving and measuring mode program-controlled circuits, a data acquisition card, an optoelectronic isolated digital I/O board, and a custom-specified linear power supply units. The system applied equal-potential back projection algorithm to reconstruct dynamic images. The relative accuracy of the system is 0.1%, the RTI noise is 11.1 mu V (bandwidth 100 Hz). Based on physical phantom, images reconstructed by the system showed that it can image dynamically to the infused saline solution, and by infusing more solution the gray changed area of the image also enlarged accordingly. For stomach filling model in vivo, the dynamic imaging processes showed that the system can clearly and sensitively monitoring the saline solution drinking into the stomach for 50 ml each time, and by drinking more saline solution the conductivity changed area of the dynamic image also enlarged accordingly.

10.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 1638-41, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-17282522

RESUMEN

It is found that Electrical Impedance Tomography(EIT) is promising in its application to the clinical image monitoring and that the Back-Projection algorithm of EIT can meet the preliminary requirements of the real-time monitoring through our work. In order to improve the computed speed and the imaged resolution, different ways of completing the algorithm were tried in this paper. Moreover, it is shown that the impedance change due to physiological saline with the concentration of not more than 50 milliliter 0.9% can be detected and imaged by our system. The above result is helpful for our further work of image monitoring by EIT.

11.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-354226

RESUMEN

The contour line of human brain was simulated by the curve-fitting methods and then the inner area was discretized by advancing-front methods which was improved at last. The curve-fitting result was similar to the CT picture of the human brain and the discrete result of inner area could be completed quickly by improved advanced-front methods. A finite element model with the contour line of human brain was built primarily which will contribute to the next algorithm study of electrical impedance tomography in human brain.


Asunto(s)
Humanos , Algoritmos , Encéfalo , Análisis de Elementos Finitos , Modelos Anatómicos , Modelos Neurológicos
12.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-588163

RESUMEN

The reverse problem of Electrical impedance tomography(EIT) is a highly ill-posed problem.It is concluded that spatial prior information could improve the final image quality.This paper proposes a new method for obtaining prior information.By this method,the inspected cross-section contour and internal structure for EIT can be achieved.