Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39219299

RESUMEN

PURPOSE: Ultrashort echo time (UTE) MRI can be a radiation-free alternative to CT for craniofacial imaging of pediatric patients. However, unlike CT, bone-specific MR imaging is limited by long scan times, relatively low spatial resolution, and a time-consuming bone segmentation workflow. METHODS: A rapid, high-resolution UTE technique for brain and skull imaging in conjunction with an automatic segmentation pipeline was developed. A dual-RF, dual-echo UTE sequence was optimized for rapid scan time (3 min) and smaller voxel size (0.65 mm3). A weighted least-squares conjugate gradient method for computing the bone-selective image improves bone specificity while retaining bone sensitivity. Additionally, a deep-learning U-Net model was trained to automatically segment the skull from the bone-selective images. Ten healthy adult volunteers (six male, age 31.5 ± 10 years) and three pediatric patients (two male, ages 12 to 15 years) were scanned at 3 T. Clinical CT for the three patients were obtained for validation. Similarities in 3D skull reconstructions relative to clinical standard CT were evaluated based on the Dice similarity coefficient and Hausdorff distance. Craniometric measurements were used to assess geometric accuracy of the 3D skull renderings. RESULTS: The weighted least-squares method produces images with enhanced bone specificity, suppression of soft tissue, and separation from air at the sinuses when validated against CT in pediatric patients. Dice similarity coefficient overlap was 0.86 ± 0.05, and the 95th percentile Hausdorff distance was 1.77 ± 0.49 mm between the full-skull binary masks of the optimized UTE and CT in the testing dataset. CONCLUSION: An optimized MRI acquisition, reconstruction, and segmentation workflow for craniofacial imaging was developed.

2.
Bone ; 177: 116900, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37714503

RESUMEN

BACKGROUND: Assessment of proximal femur trabecular bone microstructure in vivo by magnetic resonance imaging has recently been validated for acquiring information independent of bone mineral density in osteoporotic patients. However, the requisite signal-to-noise ratio (SNR) and resolution for interrogation of the trabecular microstructure at this anatomical location prolongs the scan duration and renders the imaging protocol clinically infeasible. Parallel imaging and compressed sensing (PICS) techniques can reduce the scan duration of the imaging protocol without substantially compromising image quality. The present work investigates the limits of acceleration for a commonly used PICS technique, ℓ1-ESPIRiT, for the purpose of quantifying measures of trabecular bone microarchitecture. Based on a desired error tolerance, a six-minute, prospectively accelerated variant of the imaging protocol was developed and assessed for intersession reproducibility and agreement with the longer reference scan. PURPOSE: To investigate the limits of acceleration for MRI-based trabecular bone quantification by parallel imaging and compressed sensing reconstruction, and to develop a prototypical imaging protocol for assessing the proximal femur microstructure in a clinically practical scan time. METHODS: Healthy participants (n = 11) were scanned by a 3D balanced steady-state free precession (bSSFP) sequence satisfying the Nyquist criterion with a scan duration of about 18 min. The raw data were retrospectively undersampled and reconstructed to mimic various acceleration factors ranging from 2 to 6. Trabecular volumes-of-interest in four major femoral regions (greater trochanter, intertrochanteric region, femoral neck, and femoral head) were analyzed and six relevant measures of trabecular bone microarchitecture (bone volume fraction, surface-to-curve ratio, erosion index, elastic modulus, trabecular thickness, plates-to-rods ratio) were obtained for images of all accelerations. To assess agreement, median percent error and intraclass correlation coefficients (ICCs) were computed using the fully-sampled data as reference. Based on this analysis, a prospectively 3-fold accelerated sequence with a duration of about 6 min was developed and the analysis was repeated. RESULTS: A prospective acceleration factor of 3 demonstrated comparable performance in reproducibility and absolute agreement to the fully-sampled scan. The median CoV over all image-derived metrics was generally <6 % and ICCs >0.70. Also, measurements from prospectively 3-fold accelerated scans demonstrated in general median percent errors of <7 % and ICCs >0.70. CONCLUSION: The present work proposes a method to make in vivo quantitative assessment of proximal femur trabecular microstructure with a clinically practical scan duration of about 6 min.

3.
Bone ; 171: 116743, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36958542

RESUMEN

BACKGROUND: Assessment of cortical bone porosity and geometry by imaging in vivo can provide useful information about bone quality that is independent of bone mineral density (BMD). Ultrashort echo time (UTE) MRI techniques of measuring cortical bone porosity and geometry have been extensively validated in preclinical studies and have recently been shown to detect impaired bone quality in vivo in patients with osteoporosis. However, these techniques rely on laborious image segmentation, which is clinically impractical. Additionally, UTE MRI porosity techniques typically require long scan times or external calibration samples and elaborate physics processing, which limit their translatability. To this end, the UTE MRI-derived Suppression Ratio has been proposed as a simple-to-calculate, reference-free biomarker of porosity which can be acquired in clinically feasible acquisition times. PURPOSE: To explore whether a deep learning method can automate cortical bone segmentation and the corresponding analysis of cortical bone imaging biomarkers, and to investigate the Suppression Ratio as a fast, simple, and reference-free biomarker of cortical bone porosity. METHODS: In this retrospective study, a deep learning 2D U-Net was trained to segment the tibial cortex from 48 individual image sets comprised of 46 slices each, corresponding to 2208 training slices. Network performance was validated through an external test dataset comprised of 28 scans from 3 groups: (1) 10 healthy, young participants, (2) 9 postmenopausal, non-osteoporotic women, and (3) 9 postmenopausal, osteoporotic women. The accuracy of automated porosity and geometry quantifications were assessed with the coefficient of determination and the intraclass correlation coefficient (ICC). Furthermore, automated MRI biomarkers were compared between groups and to dual energy X-ray absorptiometry (DXA)- and peripheral quantitative CT (pQCT)-derived BMD. Additionally, the Suppression Ratio was compared to UTE porosity techniques based on calibration samples. RESULTS: The deep learning model provided accurate labeling (Dice score 0.93, intersection-over-union 0.88) and similar results to manual segmentation in quantifying cortical porosity (R2 ≥ 0.97, ICC ≥ 0.98) and geometry (R2 ≥ 0.82, ICC ≥ 0.75) parameters in vivo. Furthermore, the Suppression Ratio was validated compared to established porosity protocols (R2 ≥ 0.78). Automated parameters detected age- and osteoporosis-related impairments in cortical bone porosity (P ≤ .002) and geometry (P values ranging from <0.001 to 0.08). Finally, automated porosity markers showed strong, inverse Pearson's correlations with BMD measured by pQCT (|R| ≥ 0.88) and DXA (|R| ≥ 0.76) in postmenopausal women, confirming that lower mineral density corresponds to greater porosity. CONCLUSION: This study demonstrated feasibility of a simple, automated, and ionizing-radiation-free protocol for quantifying cortical bone porosity and geometry in vivo from UTE MRI and deep learning.


Asunto(s)
Aprendizaje Profundo , Osteoporosis Posmenopáusica , Osteoporosis , Humanos , Femenino , Osteoporosis Posmenopáusica/diagnóstico por imagen , Estudios Retrospectivos , Porosidad , Hueso Cortical/diagnóstico por imagen , Densidad Ósea , Imagen por Resonancia Magnética/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA