Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Cardiothorac Vasc Anesth ; 38(10): 2213-2220, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39095213

RESUMEN

OBJECTIVES: Cardiac surgery associated-acute kidney injury is a common and serious postoperative complication of cardiac surgery, which is associated with increased postoperative morbidity and mortality. This study aimed to explore the association between cardiopulmonary bypass (CPB) blood flow rate (BFR), and major adverse kidney events (MAKEs) at day 30. DESIGN: Retrospective single-center before-after observational study. Patients were divided in 2 groups according to CPB flow rates: a first group with an institutional protocol targeting a CPB-BFR of >2.2 L/min/m² (low CPB-BFR group), and a second group with a modified institutional protocol targeting a CPB-BFR of >2.4 L/min/m² (high CPB-BFR group). The primary outcome was MAKE at 30 days, defined as the composite of death, renal replacement therapy or persistent renal dysfunction. SETTING: The data were collected from clinical routines in university hospital. PARTICIPANTS: Adult patients who underwent elective and urgent cardiac surgery without severe chronic renal failure, for whom CPB duration was ≥90 minutes. INTERVENTIONS: We included 533 patients (low CPB-BFR group, n = 270; high CPB-BFR group, n = 263). MEASUREMENTS AND MAIN RESULTS: A significant decrease in MAKE at 30 days was observed in the high CPB-BFR group (3% v 8%; odds ratio [OR], 0.779; 95% confidence interval [CI], 0.661-0.919; p < 0.001) mainly mediated by a lower 30-day mortality in the high CPB-BFR group (1% v 5%; OR, 0.697; 95% CI, 0.595-0.817; p = 0.001), as was renal replacement therapy (1% v 4%; OR, 0.739; 95% CI, 0.604-0.904; p = 0.016). CONCLUSIONS: In patients undergoing cardiac surgery, increased CPB-BFR was associated with a decrease in MAKE at 30 days including mortality and renal replacement therapy.


Asunto(s)
Lesión Renal Aguda , Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Complicaciones Posoperatorias , Puntaje de Propensión , Humanos , Puente Cardiopulmonar/efectos adversos , Masculino , Femenino , Estudios Retrospectivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Anciano , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Lesión Renal Aguda/etiología , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/diagnóstico , Velocidad del Flujo Sanguíneo/fisiología
2.
Cardiovasc Diabetol ; 23(1): 239, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38978010

RESUMEN

BACKGROUND: Type 2 diabetes (T2D) is a frequent comorbidity encountered in patients with severe aortic stenosis (AS), leading to an adverse left ventricular (LV) remodeling and dysfunction. Metabolic alterations have been suggested as contributors of the deleterious effect of T2D on LV remodeling and function in patients with severe AS, but so far, the underlying mechanisms remain unclear. Mitochondria play a central role in the regulation of cardiac energy metabolism. OBJECTIVES: We aimed to explore the mitochondrial alterations associated with the deleterious effect of T2D on LV remodeling and function in patients with AS, preserved ejection fraction, and no additional heart disease. METHODS: We combined an in-depth clinical, biological and echocardiography phenotype of patients with severe AS, with (n = 34) or without (n = 50) T2D, referred for a valve replacement, with transcriptomic and histological analyses of an intra-operative myocardial LV biopsy. RESULTS: T2D patients had similar AS severity but displayed worse cardiac remodeling, systolic and diastolic function than non-diabetics. RNAseq analysis identified 1029 significantly differentially expressed genes. Functional enrichment analysis revealed several T2D-specific upregulated pathways despite comorbidity adjustment, gathering regulation of inflammation, extracellular matrix organization, endothelial function/angiogenesis, and adaptation to cardiac hypertrophy. Downregulated gene sets independently associated with T2D were related to mitochondrial respiratory chain organization/function and mitochondrial organization. Generation of causal networks suggested a reduced Ca2+ signaling up to the mitochondria, with the measured gene remodeling of the mitochondrial Ca2+ uniporter in favor of enhanced uptake. Histological analyses supported a greater cardiomyocyte hypertrophy and a decreased proximity between the mitochondrial VDAC porin and the reticular IP3-receptor in T2D. CONCLUSIONS: Our data support a crucial role for mitochondrial Ca2+ signaling in T2D-induced cardiac dysfunction in severe AS patients, from a structural reticulum-mitochondria Ca2+ uncoupling to a mitochondrial gene remodeling. Thus, our findings open a new therapeutic avenue to be tested in animal models and further human cardiac biopsies in order to propose new treatments for T2D patients suffering from AS. TRIAL REGISTRATION: URL: https://www. CLINICALTRIALS: gov ; Unique Identifier: NCT01862237.


Asunto(s)
Estenosis de la Válvula Aórtica , Señalización del Calcio , Diabetes Mellitus Tipo 2 , Perfilación de la Expresión Génica , Mitocondrias Cardíacas , Índice de Severidad de la Enfermedad , Transcriptoma , Función Ventricular Izquierda , Remodelación Ventricular , Humanos , Estenosis de la Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/genética , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/patología , Masculino , Mitocondrias Cardíacas/metabolismo , Mitocondrias Cardíacas/patología , Femenino , Anciano , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/complicaciones , Persona de Mediana Edad , Anciano de 80 o más Años , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/genética , Disfunción Ventricular Izquierda/metabolismo , Disfunción Ventricular Izquierda/diagnóstico por imagen
4.
J Cardiothorac Surg ; 17(1): 292, 2022 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-36403033

RESUMEN

BACKGROUND: Papillary fibroelastomas (PFEs) are a rare subtype of benign primary cardiac tumours, which are most commonly found on the aortic valve. Although median sternotomy is still used frequently there has been different attempts to remove the aortic valve PFEs minimally invasively using robotic and Mini sternotomy approach. CASE PRESENTATION: We report herein a case of totally endoscopic non robotic removal of PFE of aortic valve. CONCLUSIONS: The encouraging intra and post-operative outcomes and fast recovery using totally endoscopic approach for removal of PFE shows the potential benefits of this technique.


Asunto(s)
Fibroelastoma Papilar Cardíaco , Fibroma , Neoplasias Cardíacas , Robótica , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Fibroma/diagnóstico por imagen , Fibroma/cirugía , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/cirugía , Neoplasias Cardíacas/patología , Endoscopía
5.
Innovations (Phila) ; 15(1): 88-92, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31893953

RESUMEN

Robotic assisted aortic valve surgery is still challenging and debatable. We retrospectively reviewed our cases of robotic assisted aortic valve replacement utilizing sutureless aortic valve with following surgical technique: 3 ports, 1 for endoscope and 2 for the robotic arms were inserted in the right chest and da Vinci Si robotic system (Intuitive Surgical, Sunnyvale, CA, USA) was adapted to these ports. Cardiopulmonary bypass was initiated through peripheral cannulations. A vent cannula was placed through the right superior pulmonary vein and a cardioplegia cannula in the ascending aorta. After cardioplegic arrest following aortic cross-clamp, the aortic valve was exposed through a clam shell aortotomy. Valvectomy along with decalcification was performed. Next using 3 guiding sutures the Perceval S valve (LivaNova, London, UK) was parachuted down and deployed. After confirming valve position, the aortotomy was closed. There were no major complications during the procedures and no conversion to sternotomy. Exposure of aortic valve was of high quality. Valvectomy required assistance with long scissors by the bedside surgeon for excision of the severely calcified valve cusps and effective decalcification of annulus. Postoperative convalescence was uncomplicated except for postoperative atrial fibrillation in 1 patient. Robotic assistance in aortic valve procedure enabled excellent exposure of the aortic valve and improved manipulation and suturing of the aortic annulus and aorta. There needs to be improvement of instrumentation for valve debridement and removal of calcium from the annulus. In addition, the sutureless valve technology contributes to the feasibility and the efficacy of this procedure.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Prótesis Valvulares Cardíacas , Humanos , Masculino , Resultado del Tratamiento
6.
Thorac Cardiovasc Surg ; 68(6): 462-469, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31242521

RESUMEN

BACKGROUND: In patients with secondary mitral regurgitation (MR) associated with low ejection fraction or previous heart surgery, minimally invasive mitral valve surgery without aortic cross-clamp (MIMVS-WAC) has shown promising results. We report our experience for this strategy in our centers. METHODS: Between August 2011 and April 2017, 46 patients (mean age 69 ± 11 years, 76% males) received MIMVS-WAC. Indications for this technique were prior coronary bypass surgery (26%), severe or recent left ventricular (LV) dysfunction (30%), or both (39%). The mean EuroSCORE II was 12 ± 10. RESULTS: For each procedure, we conducted right minithoracotomy and hypothermic cardiopulmonary bypass (CPB) after peripheral cannulation. Mean CPB time was 159 ± 39 minutes. A mitral valve replacement (MVR) was performed in 23 cases (50%), an annuloplasty in 22 cases (48%), and a prosthesis pannus removal in 1 case (2%). Mean hospital length of stay was 12 ± 5.4 days. We report no sternotomy conversions, six reoperations for bleeding, and three deaths at 30 days. Transfusion was requested in 62% (mean infusion 2 ± 2.4 packed red blood cells). The postoperative echocardiography showed an LV function preservation in 69% of cases and a reduction of pulmonary arterial pressure in 73% of cases. Four additional deaths occurred in the long-term follow-up (mean 637 ± 381 days, median 593 days). No mitral reoperation was required, with a MR ≤ 2 in 90% of patients. CONCLUSION: In high-risk patients, the MIMVS-WAC is a safe technique. It avoids hard dissections while ensuring excellent preservation of cardiac function.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Toracotomía , Anciano , Anciano de 80 o más Años , Femenino , Francia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Toracotomía/efectos adversos , Toracotomía/mortalidad , Factores de Tiempo , Resultado del Tratamiento
7.
Ann Thorac Surg ; 106(2): 548-554, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29580777

RESUMEN

BACKGROUND: Health-related quality of life (HRQOL) is an increasingly important issue in assessing the consequences of any surgical or medical intervention. Our study aimed to evaluate change in HRQOL 6 months after elective cardiac operations and to identify specific predictors of poor HRQOL. METHODS: In this prospective, single-center study, HRQOL was evaluated before and 6 months after the operation using the Medical Outcome Study 36-Item Short Form Health Survey questionnaire and its two components: the Physical Component Summary and the Mental Component Summary. We distinguished patients with worsening of HRQOL according to the minimal clinically important difference. All consecutive adult patients undergoing cardiac operations were included. RESULTS: The preoperative and postoperative 36-Item Short Form Health Survey questionnaires were completed by 326 patients, and 24 patients died before completing follow-up questionnaires. On the basis of the definition used, clinically significant deterioration of HRQOL was observed in 93 patients (26.6%) for the Physical Component Summary and in 99 patients (28.2%) for the Mental Component Summary. Renal replacement for acute renal failure and mechanical ventilation for longer than 48 hours were independent risk factors for Physical Component Summary and Mental Component Summary worsening or death. CONCLUSIONS: Although our study showed overall improvement of quality of life after cardiac operations, more than one-quarter of the patients manifested deterioration of HRQOL at 6 months postoperatively. The findings from this study should help clinicians to inform patients about their likely postoperative functional status and quality of life.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/psicología , Diferencia Mínima Clínicamente Importante , Calidad de Vida , Encuestas y Cuestionarios , Centros Médicos Académicos , Adulto , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Progresión de la Enfermedad , Procedimientos Quirúrgicos Electivos/efectos adversos , Procedimientos Quirúrgicos Electivos/métodos , Femenino , Estudios de Seguimiento , Francia , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Recurrencia , Medición de Riesgo , Factores de Tiempo
8.
Indian Heart J ; 69(1): 32-36, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28228303

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) for bifurcation lesions (BL) using 2 stents technique is known to be associated with high rates of procedural failure especially on the side branch (SB) mainly due to stent incomplete apposition. Stent deployment at very high pressure (SDHP) may lead to better stent expansion and apposition. However, SDHP may also be at the origin of deeper wall injury resulting into major cardiac adverse events. No data are available on evaluation of SDHP in BL treated by a mini-crush stent technique. METHODS: One hundred and thirteen consecutive patients underwent PCI for BL (Medina 1, 1, 1) using a mini-crush stent technique with SDHP defined as ≥20atm. An angiographic follow-up was performed at 6 month and clinical follow-up was obtained at a median of 3 years. RESULTS: Stent deployment mean pressures were 20±1.4atm (range 20-25) in the main vessel (MV) and 20±1.5atm (range 20-25) in SB. Simultaneous final kissing balloon was used in 92% of cases. PCI was successful in 100%. Angiographic follow-up was obtained in 83% of patients. Restenosis rate was 13% (12% restenosis in the SB) with only one case (0.8%) of SB probable thrombosis. Another case of late stent thrombosis occurred at a 3 years clinical follow-up. CONCLUSION: Compared with previously published studies in which stents were deployed at lower pressure, SDHP does not increase the restenosis rate in BL using mini-crush stent technique but seems to reduce the rate of stent thrombosis.


Asunto(s)
Angiografía Coronaria/métodos , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/cirugía , Vasos Coronarios/cirugía , Intervención Coronaria Percutánea/métodos , Anciano , Reestenosis Coronaria/epidemiología , Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Presión , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional
10.
Innovations (Phila) ; 11(5): 337-341, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27832045

RESUMEN

OBJECTIVE: In this paper, we present an endoscopic expandable sizer conceived to allow thoracoscopic aortic valve replacement with a sutureless prosthesis using a dynamic sizing of the aortic annulus. METHODS: Ten aortic torsos were prepared using a five-trocar thoracoscopic setting. Once the aortotomy was performed and the aortic valve leaflets removed, the technical feasibility of the endoscopic sizing (introduction into the trocar, expansion into the aortic annulus, determination of the valve size, and retraction) with the device was assessed. In case of successful thoracoscopic sizing, endoscopic implantation of a sutureless valve (five LivaNova Perceval prosthesis and five Medtronic 3f Enable bioprosthesis) was performed. Before ascending aorta closure, we assessed the appropriate sealing of the bioprosthesis in the native annulus with camera visualization and a nerve hook inspection. RESULTS: All the 10 endoscopic sizings were technically feasible. The scheduled aortic sutureless valve implantations were successfully performed. In all cases, fitting and placement of the sutureless bioprosthesis in the flaccid heart was satisfactory, with no paraprosthetic leakage detectable by the nerve hook. CONCLUSIONS: The use of the endoscopic expandable sizer is technically possible. In this early-stage test in the flaccid heart, selection of the valve size was satisfactory during thoracoscopic sutureless aortic bioprosthesis implantation. Further laboratory evaluation with fluid dynamics (aortic root pressurization) will be performed before a clinical study is started.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Bioprótesis , Prótesis Valvulares Cardíacas , Humanos , Diseño de Prótesis , Toracoscopía
11.
Ann Thorac Surg ; 102(4): e299-301, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27645967

RESUMEN

Totally endoscopic cardiac operations for coronary procedures and atrial septal defect repair have demonstrated improved quality of life, but they have required longer cross-clamp times compared with open operations. Although transcatheter valve implantation remains appropriate for inoperable patients, the totally endoscopic approach could be an effective treatment for lower risk patients, including complete removal of the stenotic aortic valve, while minimizing surgical chest wall trauma, and providing excellent early quality of life. Totally endoscopic aortic valve replacement procedures were previously performed with the 3f Enable bioprosthesis. We present the first case, to our knowledge, of Sorin Perceval implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
13.
Int J Cardiol ; 222: 924-930, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27526360

RESUMEN

BACKGROUND: Ischemic mitral regurgitation (IMR) is a common complication of coronary artery disease and represents an independent predictor of mortality. In the IMR the pattern of mitral valve annular dilatation is asymmetrical: this can explain the long-term incidence of recurrent mitral regurgitation after surgical annular size reduction with a symmetrical ring. The aim of this study is to analyze early and mid-term results of mitral valve repair (MVR) with the CMA IMR ETlogix ring, specifically developed for the surgical correction of IMR. METHODS: Retrospectively, we studied 157 consecutive patients who underwent MVR with the CMA ETlogix ring for the treatment of grade ≥2 IMR in our center between June 2006 and December 2012. We reported clinical and echocardiographic early and mid-term results of this surgical technique. RESULTS: Postoperative 30days mortality was 6.3%. Postoperative echocardiography evaluation at discharge revealed the absence of residual MR in 70%, mild MR in 26.5% and moderate MR in 3.5% of patients respectively. Median echographic follow-up time was 28 (3-84) months: survival rate was 92.1% at 32months; free from mitral valve reoperation rate was 97.5% and grade >2 MR recurrence free survival rate was 96.6%. CONCLUSION: There are a few reports in the literature concerning the mid-term results of IMR surgical correction with CMA Etlogix ring. Our study, taking into account a large series of patients and an important follow-up period, demonstrates the effectiveness of this surgical repair technique reporting a low mid-term incidence of recurrent MR.


Asunto(s)
Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Isquemia Miocárdica/complicaciones , Anciano , Angiografía Coronaria , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/etiología , Isquemia Miocárdica/diagnóstico , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
14.
Acta Biomater ; 42: 273-285, 2016 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-27345137

RESUMEN

UNLABELLED: Although hundreds of samples obtained from ascending thoracic aortic aneurysms (ATAA) of patients undergoing elective surgical repair have already been characterized biomechanically, their rupture properties were always derived from uniaxial tensile tests. Due to their bulge shape, ATAAs are stretched biaxially in vivo. In order to understand the biaxial rupture of ATAAs, our group developed a novel methodology based on bulge inflation and full-field optical measurements. The objective of the current paper is threefold. Firstly, we will review the failure properties (maximum stress, maximum stretch) obtained by bulge inflation testing on a cohort of 31 patients and compare them with failure properties obtained by uniaxial tension in a previously published study. Secondly, we will investigate the relationship between the failure properties and the age of patients, showing that patients below 55years of age display significantly higher strength. Thirdly, we will define a rupture risk based on the extensibility of the tissue and we will show that this rupture risk is strongly correlated with the physiological elastic modulus of the tissue independently of the age, ATAA diameter or the aortic valve phenotype of the patient. STATEMENT OF SIGNIFICANCE: Despite their medical importance, rupture properties of ascending thoracic aortic aneurysms (ATAA) subjected to biaxial tension were inexistent in the literature. In order to address this lack, our group developed a novel methodology based on bulge inflation and full-field optical measurements. Here we report rupture properties obtained with this methodology on 31 patients. It is shown for the first time that rupture occurs when the stretch applied to ATAAs reaches the maximum extensibility of the tissue and that this maximum extensibility correlates strongly with the elastic properties. The outcome is a better detection of at-risk individuals for elective surgical repair.


Asunto(s)
Aneurisma de la Aorta Torácica/patología , Rotura de la Aorta/patología , Adulto , Anciano , Aneurisma de la Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/fisiopatología , Rotura de la Aorta/cirugía , Fenómenos Biomecánicos , Demografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Mecánico , Resistencia a la Tracción , Adulto Joven
15.
Cardiovasc Revasc Med ; 17(4): 290-1, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27150502

RESUMEN

Our case reports the first migration of a stent already deployed at high pressure in the main vessel during a 2-stent strategy for a bifurcation lesion using T and protrusion technique. The Kissing balloon was not optimal and could have led to an insufficient strut/cell opening and then to LAD stent pulled back into the artery tree. This case report highlights the importance of an optimal Kissing Balloon in two stent bifurcation technique.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Migración de Cuerpo Extraño/etiología , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Remoción de Dispositivos , Everolimus/administración & dosificación , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugía , Humanos , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Resultado del Tratamiento
16.
J Card Surg ; 31(6): 373-5, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27109166

RESUMEN

An aorta to right atrium fistula is rare. We report a case of idiopathic aortic root to right atrial fistula with right heart failure and review the literature. doi: 10.1111/jocs.12751 (J Card Surg 2016;31:373-375).


Asunto(s)
Aorta , Enfermedades de la Aorta/diagnóstico , Atrios Cardíacos , Insuficiencia Cardíaca/etiología , Fístula Vascular/diagnóstico , Enfermedades de la Aorta/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Fístula Vascular/complicaciones
17.
Int J Cardiol ; 211: 71-8, 2016 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-26977583

RESUMEN

BACKGROUND: Minimally invasive aortic valve replacement has so far required a minithoracotomy or a ministernotomy. We present here the first series of totally endoscopic aortic valve replacement (TEAVR). METHODS: Between June 2013 and April 2015, 14 consecutive patients (12 males, mean age=76 ± 5.4 years) with a mean EuroSCORE II of 2.72 ± 0.03% underwent TEAVR. A five trocar setting was used in all patients: after ablation of the native valve, a Nitinol stented sutureless 3f Enable Medtronic valve, compressed into the main working trocar, was introduced into the thorax and then expanded in the aortic root. RESULTS: Among the 14 patients, a thoracoscopic approach was successful in 13 (92.8%) and conversion into an open surgery using the right anterior minithoracotomy was necessary to close the aortotomy in one case. Mean cross-clamping and cardiopulmonary (CPB) times were 112 ± 18 and 161 ± 31 min, respectively. All patients left the surgical unit within 8 days after the operation without any paravalvular leakage. There was no paravalvular regurgitation, conductive block or any major adverse event at a mean follow-up of 10 ± 4 months (range 2-16). CONCLUSIONS: TEAVR is feasible and safe in a selected subset of patients. Closed chest surgery has the potential to become the future approach of the isolated aortic valve replacement in low risk patients but further technical refinement and larger studies are necessary to reduce operative durations and enhance reproducibility.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Toracoscopía/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Toracoscopía/instrumentación
18.
J Clin Monit Comput ; 30(6): 783-789, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26939694

RESUMEN

Alteration of tissue perfusion is a main contributor of organ dysfunction. In cardiac surgery, the importance of organ dysfunction is associated with worse outcome. Central venous-arterial difference in CO2 tension (ΔCO2) has been proposed as a global marker of the adequacy of tissue perfusion in shock states. We hypothesized that ΔCO2 could be increased in case of postoperative organ failure or worse outcome. In this monocentric retrospective cohort study, we retrieved, from our database, 220 consecutive patients admitted in intensive care after an elective cardiac surgery. Four time points were formed: ICU admission, and 6, 24 and 48 h after. A ΔCO2 below 6 mmHg defined the normal range values. The SOFA score, intensive care unit and hospital length of stay, hospital and 6-month mortality rate were recorded. We compared patient with low ΔCO2 (<6 mmHg) and high ΔCO2 (≥6 mmHg). We included 55 (25 %) and 165 patients in low and high ΔCO2 groups, respectively. The SOFA score, the hospital and 6 months mortality rate were higher in patients with low ΔCO2. Surprisingly, we did not find results previously published in other surgical settings. In cardiac surgery, ΔCO2 has a low predictive value of outcome.


Asunto(s)
Dióxido de Carbono/sangre , Procedimientos Quirúrgicos Cardíacos/métodos , Anciano , Anestesia , Arterias/fisiología , Análisis de los Gases de la Sangre , Dióxido de Carbono/química , Cuidados Críticos , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Unidades de Cuidados Intensivos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Perfusión , Periodo Posoperatorio , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estudios Retrospectivos , Riesgo , Temperatura , Factores de Tiempo , Venas/fisiología
20.
Ann Thorac Surg ; 101(5): 1716-23, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26778389

RESUMEN

BACKGROUND: In this article we present a consecutive single-center experience of implantation of the Medtronic 3f Enable aortic valve (Medtronic Inc, Minneapolis, MN). METHODS: Between March 2011 and October 2014, 200 consecutive patients (mean age, 76.4 ± 5.9 years; logistic EuroScore, 7.8% ± 7.0%) in our unit received the 3f Enable valve. This is a retrospective analysis of this prospective monocentric cohort. RESULTS: The 3f Enable valve could be implanted in all the scheduled 141 isolated aortic valve replacement (AVR) procedures (14 full sternotomies, 73 ministernotomies, 44 minithoracotomies, and 10 thoracoscopic approaches) and 59 combined procedures (all using full sternotomy). Reclamping was necessary in 7 (3.5%) patients (paravalvular leakage [PVL] was ≥ grade 1 because of undersizing or prosthetic misalignment); mean cross-clamp and cardiopulmonary bypass (CPB) times were 65 ± 31 and 91 ± 39 minutes, respectively. Sixteen (8%) patients required early implantation of a pacemaker (PM). At a mean follow-up of 12.6 ± 8.1 months, mean transvalvular gradient and effective orifice area (EOA) were 9.8 ± 4.4 mm Hg and 1.87 ± 0.6 cm(2), respectively. Mild PVL was present in 7 (3.5%) patients and moderate PVL was present in 5 (2.5%) patients. No device migration was registered, and no moderate PVL was detected in the last 100 patients of the cohort. Overall, 3-year survival was 78%. CONCLUSIONS: The 3f Enable valve shows excellent results regarding PVL but in our experience required a learning curve and a refinement of the technique of implantation. Use of the prosthesis was possible in various less invasive approaches.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA