1.
Clin Oral Investig ; 28(9): 474, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39112646

RESUMEN

OBJECTIVES: Inadequate resection margins of less than 5 mm impair local tumor control. This weak point in oncological safety is exacerbated in bone-infiltrating tumors because rapid bone analysis procedures do not exist. This study aims to assess the bony resection margin status of bone-invasive oral cancer using laser-induced breakdown spectroscopy (LIBS). MATERIALS AND METHODS: LIBS experiments were performed on natively lasered, tumor-infiltrated mandibular cross-sections from 10 patients. In total, 5,336 spectra were recorded at defined distances from the tumor border. Resection margins < 1 mm were defined as very close, from 1-5 mm as close, and > 5 mm as clear. The spectra were histologically validated. Based on the LIBS spectra, the discriminatory power of potassium (K) and soluble calcium (Ca) between bone-infiltrating tumor tissue and very close, close, and clear resection margins was determined. RESULTS: LIBS-derived electrolyte emission values of K and soluble Ca as well as histological parameters for bone neogenesis/fibrosis and lymphocyte/macrophage infiltrates differ significantly between bone-infiltrating tumor tissue spectra and healthy bone spectra from very close, close, and clear resection margins (p < 0.0001). Using LIBS, the transition from very close resection margins to bone-infiltrating tumor tissue can be determined with a sensitivity of 95.0%, and the transition from clear to close resection margins can be determined with a sensitivity of 85.3%. CONCLUSIONS: LIBS can reliably determine the boundary of bone-infiltrating tumors and might provide an orientation for determining a clear resection margin. CLINICAL RELEVANCE: LIBS could facilitate intraoperative decision-making and avoid inadequate resection margins in bone-invasive oral cancer.


Asunto(s)
Márgenes de Escisión , Neoplasias de la Boca , Análisis Espectral , Humanos , Neoplasias de la Boca/cirugía , Neoplasias de la Boca/patología , Análisis Espectral/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Invasividad Neoplásica , Calcio/análisis , Potasio/análisis , Mandíbula/cirugía , Mandíbula/patología , Rayos Láser
2.
Int J Mol Sci ; 25(5)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38473853

RESUMEN

Laser-induced breakdown spectroscopy (LIBS) was recently introduced as a rapid bone analysis technique in bone-infiltrating head and neck cancers. Research efforts on laser surgery systems with controlled tissue feedback are currently limited to animal specimens and the use of nontumorous tissues. Accordingly, this study aimed to characterize the electrolyte composition of tissues in human mandibular bone-infiltrating head and neck cancer. Mandible cross-sections from 12 patients with bone-invasive head and neck cancers were natively investigated with LIBS. Representative LIBS spectra (n = 3049) of the inferior alveolar nerve, fibrosis, tumor stroma, and cell-rich tumor areas were acquired and histologically validated. Tissue-specific differences in the LIBS spectra were determined by receiver operating characteristics analysis and visualized by principal component analysis. The electrolyte emission values of calcium (Ca) and potassium (K) significantly (p < 0.0001) differed in fibrosis, nerve tissue, tumor stroma, and cell-rich tumor areas. Based on the intracellular detection of Ca and K, LIBS ensures the discrimination between the inferior alveolar nerve and cell-rich tumor tissue with a sensitivity of ≥95.2% and a specificity of ≥87.2%. The heterogeneity of electrolyte emission values within tumorous and nontumorous tissue areas enables LIBS-based tissue recognition in mandibular bone-infiltrating head and neck cancer.


Asunto(s)
Neoplasias de Cabeza y Cuello , Rayos Láser , Animales , Humanos , Análisis Espectral/métodos , Electrólitos , Mandíbula , Fibrosis
3.
Materials (Basel) ; 16(8)2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37109929

RESUMEN

Aligner therapy for orthodontic tooth movement is gaining importance in orthodontics. The aim of this contribution is to introduce a thermo- and water-responsive shape memory polymer (SMP), which could lay the foundation for a new type of aligner therapy. The thermal, thermo-mechanical, and shape memory properties of thermoplastic polyurethane were studied by means of differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), and various practical experiments. The glass transition temperature of the SMP relevant for later switching was determined to be 50 °C in the DSC, while the tan δ peak was detected at 60 °C in the DMA. A biological evaluation was carried out using mouse fibroblast cells, which showed that the SMP is not cytotoxic in vitro. On a digitally designed and additively manufactured dental model, four aligners were fabricated from an injection-molded foil using a thermoforming process. The aligners were then heated and placed on a second denture model which had a malocclusion. After cooling, the aligners were in a programmed shape. The movement of a loose, artificial tooth and thus the correction of the malocclusion could be realized by thermal triggering the shape memory effect, at which the aligner corrected a displacement with an arc length of approximately 3.5 mm. The developed maximum force was separately determined to be about 1 N. Moreover, shape recovery of another aligner was realized within 20 h in 37 °C water. In perspective, the present approach can help to reduce the number of orthodontic aligners in therapy and thus avoid excessive material waste.