1.
Sensors (Basel) ; 24(17)2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39275429

RESUMEN

A paramagnetic A3B-type Mn(III)-porphyrin was synthesized and characterized by physical-chemical methods (UV-Vis, FT-IR, 1H-NMR spectroscopy). The obtained compound was tested as a sensitive material for the spectrophotometric and potentiometric detection of iodine species. Using UV-Vis spectroscopy, the triiodide anions could be detected with high precision in the concentration interval of 1.02 × 10-5 to 2.3 × 10-5 M, with an LOD of 9.44 × 10-6 M. The PVC-based electrode using DOP as a plasticizer showed a sensitivity toward iodide in a wide concentration range of 1.0 × 10-5 to 1.0 × 10-1 M, with an LOD of 8.0 × 10-6 M. Both methods are simple, low-cost, and efficient for the detection of iodine species in synthetic samples and pharmaceuticals.

2.
Int J Mol Sci ; 24(24)2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38139093

RESUMEN

The multifunctionality of an A3B mixed-substituted porphyrin, namely 5-(4-carboxyphenyl)-10,15,20-tris(4-methylphenyl)porphyrin (5-COOH-3MPP), was proven due to its capacity to detect procaine by different methods, depending on the polymer matrix in which it is incorporated. The hybrid nanomaterial containing k-carrageenan and AuNPs (5-COOH-3MPP-k-carrageenan-AuNPs) was able to optically detect procaine in the concentration range from 5.76 × 10-6 M to 2.75 × 10-7 M, with a limit of detection (LOD) of 1.33 × 10-7 M. This method for the detection of procaine gave complementary results to the potentiometric one, which uses 5-COOH-3MPP as an electroactive material incorporated in a polyvinylchloride (PVC) membrane plasticized with o-NPOE. The detected concentration range by this ion-selective membrane electrode is wider (enlarged in the field of higher concentrations from 10-2 to 10-6 M), linearly dependent with a 53.88 mV/decade slope, possesses a detection limit of 7 × 10-7 M, a response time of 60 s, and has a certified stability for a working period of six weeks.


Asunto(s)
Nanopartículas del Metal , Porfirinas , Procaína , Carragenina , Oro , Electrodos de Iones Selectos
3.
Sensors (Basel) ; 18(7)2018 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-30012951

RESUMEN

Pt(II) 5,10,15,20-tetra(4-methoxy-phenyl)-porphyrin (PtTMeOPP) was used in the construction of new ion-selective sensors. The potentiometric response characteristics (slope and selectivity) of iodide and bromide-selective electrodes based on (PtTMeOPP) metalloporphyrin in o-nitrophenyloctylether (NPOE), dioctylphtalate (DOP) and dioctylsebacate (DOS) plasticized poly(vinyl chloride) membranes are compared. The best results were obtained for the membranes plasticized with DOP and NPOE. The sensors have linear responses with near-Nernstian slopes toward bromide and iodide ions and good selectivity. The membrane plasticized with NPOE was electrochemically characterized using the EIS method to determine its water absorption and the diffusion coefficient into the membrane.

4.
Molecules ; 19(12): 21239-52, 2014 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-25525824

RESUMEN

The present report deals with the tailoring, preparation and characterization of novel nanomaterials sensitive to CO2 for use in detection of this gas during space habitation missions. A new nanostructured material based on mixed substituted asymmetrical A3B porphyrin: 5-(4-pyridyl)-10,15,20-tris(3,4-dimethoxyphenyl)-porphyrin (PyTDMeOPP) was synthesized and characterized by 1H-NMR, FT-IR, UV-vis, fluorescence, MS, HPLC and AFM. Introducing one pyridyl substituent in the 5-meso-position of porphyrin macrocycle confers some degree of hydrophilicity, which may cause self-assembly properties and a better response to increased acidity. The influence of pH and nature of the solvent upon H and J aggregates of the porphyrin are discussed. Porphyrin aggregation at the air-THF interface gave a triangular type morphology, randomly distributed but uniformly oriented. When deposition was made by multiple drop-casting operations, a network of triangles of uniform size was created and a porous structure was obtained, being reorganized finally in rings. When the deposition was made from CHCl3, ring structures ranging in internal diameter from 300 nm to 1 µm, but with the same width of the corona circular of approx. 200 nm were obtained. This porphyrin-based material, capable of generating ring aggregates in both THF and CHCl3, has been proven to be sensitive to CO2 detection. The dependence between the intensity of porphyrin UV-vis absorption and the concentration of CO2 has a good correlation of 98.4%.


Asunto(s)
Dióxido de Carbono/análisis , Nanoestructuras/química , Porfirinas/química , Monitoreo del Ambiente , Interacciones Hidrofóbicas e Hidrofílicas , Nanoestructuras/ultraestructura , Vuelo Espacial , Propiedades de Superficie
5.
Chem Cent J ; 7(1): 111, 2013 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-23829792

RESUMEN

BACKGROUND: Copper is an essential trace element with a great importance in industry, environment and biological systems. The great advantage of ion-selective sensors in comparison with other proposed techniques is that they are measuring the free metal ion activity which is responsible for their toxicity. Porphyrins are known to be among the best ionophores in formulation of ion-selective sensors. RESULTS: A symmetrically substituted meso-porphyrin, namely: 5,10,15,20-tetrakis(4-allyloxyphenyl)porphyrin (TAPP) was used in the construction of a new copper selective-sensor and was also tested for the removal of copper from waste waters. The potentiometric response characteristics (slope and selectivity) of copper-selective electrodes based on TAPP in o-nitrophenyloctylether (o-NPOE), dioctyl phtalate (DOP) and dioctyl sebacate (DOS) plasticized with poly(vinyl chloride) membranes are compared. CONCLUSIONS: The best results were obtained for the membrane plasticized with DOP. The sensor has linear response in the range 1x10-7 - 1x10-1 M with 28.4 ± 0.4 mV/decade near-Nernstian slope towards copper ions and presents good selectivity. Due to its chelating nature, the same porphyrin was also tested for the retention of copper from synthetic copper samples, showing a maximum adsorption capacity of 280 mg/g.

6.
Sensors (Basel) ; 12(6): 8193-203, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22969395

RESUMEN

Three A(3)B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10(-7)-1 × 10(-1) M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples.


Asunto(s)
Técnicas Biosensibles/instrumentación , Hierro/análisis , Porfirinas/química , Electrodos , Concentración de Iones de Hidrógeno , Iones/análisis , Límite de Detección , Membranas Artificiales , Potenciometría , Soluciones , Factores de Tiempo , Agua/química
7.
Sensors (Basel) ; 10(10): 8850-64, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22163384

RESUMEN

Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac-selective electrodes. The electroactive material was incorporated either in PVC or a sol-gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 × 10(-6) - 1 × 10(-2) M with a slope of -59.7 mV/dec diclofenac, a detection limit of 1.5 × 10(-6) M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.


Asunto(s)
Diclofenaco/análisis , Metaloporfirinas/química , Potenciometría/instrumentación , Potenciometría/métodos , Diclofenaco/química , Electrodos
8.
Sensors (Basel) ; 8(8): 4995-5004, 2008 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-27873797

RESUMEN

Two functionalized porphyrins: 5,10,15,20-tetrakis(3,4-dimethoxyphenyl) porphyrin (A) and 5,10,15,20-tetrakis(3-hydroxyphenyl)porphyrin (B) obtained and characterized by us were used as ionophores (I) for preparing PVC-based membrane sensors selective to Ag⁺, Pb2+ and Cu2+. The membranes were prepared using three different plasticizers: (bis(2-ethylhexyl)sebacate (DOS), dioctylphtalate (DOP), o-nitrophenyl octyl ether (NPOE) and potassium tetrakis(4-chlorophenyl)borate (KTClPB) as additive. The functional parameters (linear concentration range, slope and selectivity) of the sensors with membrane composition: (I:PVC:KTClPB:Plasticizer) in different ratios were investigated. The best results were obtained for the membranes in the ratio I:PVC:KTClPB:Plasticizer 10:165:5:330. The influence of pH on the sensors response was studied. The sensors were used for a period of four months and their utility has been tested on synthetic and real samples.

9.
Comb Chem High Throughput Screen ; 10(6): 466-72, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17896942

RESUMEN

Porphyrins play a major role as active photosensitizers in noninvasive optical photodynamic therapy (PDT). In a modular approach, this paper presents a short review of the recent developments of porphyrin structures and materials with improved photosensitizing properties and then presents the synthesis and characterization of a series of new second generation asymmetrical meso-tetraphenylporphyrins varied by substituent in the meta positions of the phenyl rings with either -OH or -OCH3 groups, whereas in the para positions only with -OCH3 groups. The new series of differentially functionalized porphyrins were obtained by a combinatorial multicomponent synthesis (Adler-Longo method) by simultaneously using two different aldehydes: 3,4-dimethoxybenzaldehyde and 3-hydroxybenzaldehyde. The porphyrins were isolated, purified and characterized by HPLC, TLC, UV-vis, fluorescence, MS, 1H-NMR, and 13C-NMR analysis, accompanied by DEPT 135 experiments. Because of the fact that the medium in cancerous tissues is often more acidic than in normal tissues, the capacity of these porphyrins to exist simultaneously in aggregated and protonated forms was also investigated, in tetrahydrofuran (THF) and acid THF-water systems, underlying the changes in the photophysical behaviour. The relative fluorescence quantum yields (Phif) were calculated in comparison with meso-tetraphenylporphyrin (TPP), and the values between 0.14-0.26 were found to be promising for further trials. The series of asymmetrically substituted tetraphenylporphyrins, as the new class of supramolecular materials, are suitable for further functionalization in order to improve their photophysical properties, and they could represent interesting potential PDT photosensitizers.


Asunto(s)
Técnicas Químicas Combinatorias/métodos , Diseño de Fármacos , Fotoquimioterapia , Fármacos Fotosensibilizantes/síntesis química , Porfirinas/síntesis química , Fármacos Fotosensibilizantes/química , Porfirinas/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA