RESUMEN
High concentrations of inorganic arsenic in groundwater for human consumption is a worldwide common problem. Particularly, the determination of As(III) becomes important, since this species is more toxic than organic, pentavalent and elemental arsenic forms. In this work, a 3D-printed device that included a 24-well microplate was developed to perform the colourimetric kinetic determination of arsenic (III) by digital movie analysis. A smartphone camera attached to the device was used to take the movie during the process where As(III) inhibited the decolourization of methyl orange. The movie images were subsequently transformed from RGB to YIQ space to obtain a new analytical parameter called "d", which was related to the chrominance of the image. Then, this parameter allowed the determination of the inhibition time of reaction (tin), which was linearly correlated with the concentration of As(III). A linear calibration curve (R = 0.9995) in the range from 5 µg L-1 to 200 µg L-1 was obtained. The method was precise (RSD = 1.2%), and the limits of detection (LOD) and quantification (LOQ) were 1.47 µg L-1 and 4.44 µg L-1, respectively. These values were lower than the limit established by the World Health Organization for total arsenic in drinking water (10 µg L-1). The accuracy of the method was assessed by a recovery study with optimal results (94.3%-104.0%). Additionally, the Analytical GREEnness metric approach was applied, obtaining a score 1.7 times higher than previously published works. The method is simple, portable and low-cost, being in compliance with various principles of green analytical chemistry.
RESUMEN
Natural Deep Eutectic Solvents (NADES) are highly important for Green Chemistry principles and can be used instead of harmful organic solvents. Indeed, nowadays smartphone-based analytical devices can replace some traditional laboratory equipment. In the present work, a smartphone based dual spectrophotometer and spectrofluorometer device was designed, 3D manufactured, and validated. A resolution of 0.241 ± 0.010 pixel.nm-1 and a stability comparable with commercial instruments were obtained. Using the proposed device it was possible, for the first time, to study the role of water in NADES (fructose:urea:water) preparation, by testing the influence of structural and dilution water. In this sense, it was observed that when water was added before NADES preparation (integrated into the superstructure of the solvent), fluorescence and absorbance intensities sharply decayed (up to 90% and 95%, respectively). In contrast, dilution water had minor effects on spectroscopic features of the eutectic system, which was expressed as 29% and 23% of diminution of signal intensities for both techniques. The obtained results suggest that the moment the water is added plays a significant role in NADES properties.
Asunto(s)
Teléfono Inteligente , Agua , Extractos Vegetales , Solventes , Análisis EspectralRESUMEN
A novel flow injection analysis (FIA) method with Rayleigh light scattering (RLS) detection was developed for the determination of total protein concentrations. This method is based on the weak intensity of RLS of bromothymol blue (BB) (3',3"-dibromothymolsulfonephthalein) which can be enhanced by the addition of protein in weakly acidic solution. A common spectrofluorimeter was used as a detector. It was proved that the application of this method to quantify the total proteins in real samples by using bovine serum albumin was possible. The RLS signal was detected at lambda(ex)= lambda(em)=572 nm. The linear range was 7.0-70.0 microg mL(-1), the detection limit was 3.75 microg mL(-1), the reproducibility was 5.5% (n=7), and the sample throughput was 26 h(-1).