Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Int Endod J ; 57(11): 1689-1698, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38984709

RESUMEN

AIM: To compare the effects of Cervical Access Cavity (CervAC) and Traditional Access Cavity (TradAC) on root canal preparation, root canal filling, and fracture resistance in mandibular incisors. METHODOLOGY: Twenty recently extracted and intact mandibular incisors were initially scanned using a micro-CT device. The specimens were anatomically matched to create two groups (n = 10). A wedge-shaped non-carious cervical lesion (NCCL) was created on the buccal aspect of all teeth using a double-faced segmented diamond disc. In group 1, a TradAC was prepared, whilst in group 2, access was created through the simulated NCCL using a round diamond bur 1012. After root canal preparation with Rotate instruments sizes 15/0.04, 20/0.04, and 25/0.04, the teeth were scanned again and evaluated for root canal volume and surface area, static voxels, volume of removed dental tissue, and dentine thickness. After that, the root canals were filled using the single-cone technique, teeth were restored with composite resin, and subsequently rescanned to calculate the volume of filling materials and voids. Then, the restored teeth were subjected to fracture resistance tests using a universal testing machine. Statistical comparisons between groups were performed with the Mann-Whitney test or the Student's t-test, with a statistical significance level of 5%. RESULTS: Statistical comparisons indicated no significant differences between groups in terms of root canal volume, surface area, static voxels, removed root dentine, root canal filling volume, percentage of voids, or fracture resistance load (p > .05). Conversely, teeth prepared with TradAC showed a significantly higher percentage of dental tissue removed from the crown (p = .001) and a greater volume of filling material remnants in the pulp chamber (p < .001) compared to the CervAC group. A significantly lower percentage reduction in dentine thickness was observed only on the mesial aspect of root at Level 1 in TradAC group (p = .008). CONCLUSIONS: CervAC can be considered a viable alternative approach in the presence of NCCL in mandibular incisors.


Asunto(s)
Incisivo , Mandíbula , Obturación del Conducto Radicular , Preparación del Conducto Radicular , Fracturas de los Dientes , Humanos , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Microtomografía por Rayos X , Cuello del Diente/patología , Cavidad Pulpar , Técnicas In Vitro
2.
Aust Endod J ; 50(2): 341-351, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38715465

RESUMEN

This study assessed canal preparation effects on disinfection and dentin preservation. Thirty mandibular incisors were paired into two experimental groups (n = 10). Following contamination, the initial microbial sample was collected. Instruments 30/0.03 (Group 1) and 30/0.05 (Group 2) were employed and a second sample was obtained. Canals were enlarged using instruments 40/0.03 and 40/0.05, respectively, and a third sample was collected. Final irrigation was performed, and sample S4 obtained. A final scan evaluated volume, surface area, unprepared areas, removed dentin and dentin thickness. Data were analysed using Student t-test, Mann-Whitney, Kruskal-Wallis and Dunn tests. A significant difference was observed between S1 and other time points (p < 0.05). Comparison between groups showed no differences in bacterial loads and in the percentage of microbial reduction (p > 0.05). Group 2 exhibited greater reduction in dentin thickness than group 1 in the mesial aspect of the root (p < 0.05). Instrument 30/0.03 might provide effective disinfection and safety during mandibular incisors canal preparation.


Asunto(s)
Desinfección , Incisivo , Mandíbula , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Desinfección/métodos , Cavidad Pulpar/microbiología , Diseño de Equipo , Dentina/microbiología , Carga Bacteriana
3.
J Endod ; 50(8): 1151-1158, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38796056

RESUMEN

INTRODUCTION: To compare the stress produced on the walls of simulated canals by rotary instruments with varied tip and taper sizes. METHODS: Ninety isotropic transparent blocks, each containing a 60-degree curved canal, were distributed into 18 groups (n = 5) based on the instrument tip (sizes 10, 15, 20, 25, 30, and 35) and taper (sizes 0.02, 0.04, and 0.06). The blocks were fixed in a circular polariscope setup for dark field analysis. A digital camera was employed to capture the real-time birefringence patterns generated by each instrument. Digital image frames, corresponding to the instrument reaching the end of each canal third, were extracted and evaluated by 2 independent observers for the stress generation on canal walls. The data analysis employed a semi-quantitative scale ranging from 0 to 5. Cohen's Kappa coefficient test was used to determine the inter-observer agreement while the results were compared using Kruskal-Wallis test followed by an all-pairwise posthoc procedure (α = 5%). RESULTS: Inter-observer agreement was 0.95. A significant influence of the tip size on stress was observed across the coronal (P = .011), middle (P = .006), and apical (P = .026) thirds. In contrast, taper size did not affect the stress induced at the coronal (P = .509), middle (P = .958), or apical (P = .493) thirds. The variations in tip and taper sizes did not result in a significant stress differences among the thirds (P = .181). CONCLUSIONS: The stress significantly increased across all canal thirds with larger tip sizes of rotary instruments, whereas the taper sizes did not influence the stress when compared to the canal thirds.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Preparación del Conducto Radicular/instrumentación , Humanos , Diseño de Equipo , Análisis del Estrés Dental , Estrés Mecánico , Instrumentos Dentales , Elasticidad
4.
Int Endod J ; 57(5): 601-616, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38376108

RESUMEN

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Asunto(s)
Instrumentos Dentales , Titanio , Estudios Transversales , Diseño de Equipo , Ensayo de Materiales , Estrés Mecánico , Titanio/química , Preparación del Conducto Radicular , Metalurgia
5.
Aust Endod J ; 50(1): 60-68, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37876340

RESUMEN

This study evaluated the impact of long-term storage conditions (medium and time) on the development of experimental dentinal microcracks through micro-computed tomography. Sixty freshly extracted premolars were stored in formalin, water, or dry conditions (n = 20) and scanned after 72 h, 30 days, 6 months and 3 years of extraction. The effect of the storage medium and time on the occurrence of dentinal defects was statistically evaluated. A total of 211 000 images were screened revealing the existence of 11 519 slices with dentinal defects. Dry conditions significantly contributed to the development of new defects in all time points. During the 3-year follow-up period, no new defects were detected in the teeth that were stored in water and, in a single tooth, in the formalin group, after 6 months of storage.


Asunto(s)
Fracturas de los Dientes , Humanos , Dentina/diagnóstico por imagen , Microtomografía por Rayos X , Preparación del Conducto Radicular , Agua , Formaldehído
7.
Int Endod J ; 56(11): 1399-1411, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37566206

RESUMEN

AIM: The aim of this study is to compare the stress produced on the internal walls of simulated canals by nine rotary and four reciprocating systems. METHODOLOGY: Sixty-five isotropic transparent blocks containing a 60° curved and tapered simulated canal were selected and distributed into 13 groups (n = 5) according to the preparation system: BioRace, HyFlex EDM, iRaCe, Mtwo, One RECI, ProTaper Next, RaCe EVO, Reciproc, Reciproc Blue, R-Motion, VDW.ROTATE, XP-Endo Rise Shaper, and XP-Endo Shaper. Each resin block was mounted in a vice and a digital camera recorded the entire sequence of each preparation system through a circular polariscope set for dark field analysis. The video frames when each instrument reached the end of the coronal, middle, and apical thirds of the canal were extracted from the recordings and analysed by two independent observers regarding the stress generated on the canal walls using a semi-quantitative evaluation on a 0-5 scale. Intra- and inter-observer agreement were subjected to the Cohen's Kappa coefficient test, whilst the experimental results were compared using Kruskal-Wallis test post hoc pairwise comparisons with Bonferroni correction (α = 5%). RESULTS: The inter- and intra-observer agreement were 0.98 and 1, respectively. Most instruments demonstrated acceptable performance (scores ≤ 2) in all thirds. Other instruments, such as the HyFlex EDM 25.12 (coronal and middle thirds), Reciproc Blue R25 and Reciproc R25 (coronal and apical thirds), R-Motion 30.04 (apical third), and VDW.ROTATE 20.05 (apical third) showed scores higher than 3. Statistical analysis revealed a significant difference amongst the tested systems at the coronal, middle, and apical thirds (p < .05). CONCLUSION: None of the canal instrumentation protocols were stress-free, showing varying levels of stress concentrations. Various factors seemed to influence the magnitude of stress and its distribution pattern on the canal walls. Overall, instruments characterized by a larger taper, lower speed, reciprocating motion, and made of heat-treated NiTi alloy exhibited higher patterns of stress distribution.

8.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37594701

RESUMEN

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Asunto(s)
Níquel , Titanio , Humanos , Cavidad Pulpar , Metalurgia , Diente Molar
9.
Aust Endod J ; 49(3): 700-710, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37489612

RESUMEN

This study evaluated unprepared canal areas, volume of dentine removal, and dentine thickness after the progressive enlargement of the buccal canals of 22 maxillary molars, with and without the MB2, using instruments with the same tip size (0.25 mm) but 4 different tapers (0.03, 0.05, 0.06 and 0.08 v). Micro-CT scans were performed after each instrument. Data were compared using a general linear mixed model post hoc comparisons with Kenward-Roger for Wald F tests (α = 5%). After each treatment step, it was observed an increase in the percentage volume of removed dentine and a decrease in the unprepared areas and dentine thickness at the pericervical region of all canals (p < 0.05). The percentage reduction of dentine thickness in MB2 canal was higher than in the mesiobuccal and distobuccal canals (p < 0.05). Knowledge of pre-operative dimensions and dentine thickness before enlargement of buccal canals of maxillary molars is an important factor to avoid excessive dentine removal.


Asunto(s)
Cavidad Pulpar , Diente Molar , Humanos , Microtomografía por Rayos X , Cavidad Pulpar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Hipertrofia , Conocimiento , Preparación del Conducto Radicular
10.
Int Endod J ; 56(9): 1024-1041, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37254176

RESUMEN

BACKGROUND: The results of vital pulp treatments in permanent teeth have been encouraging. Currently, pulpotomy treatment for permanent teeth primarily utilizes mineral trioxide aggregate (MTA) as the dressing material, followed by calcium hydroxide. While other calcium-silicate-based cements have been suggested for pulpotomy, there is a limited number of studies evaluating their long-term effectiveness. OBJECTIVES: The objective of this systematic review and meta-analysis was to evaluate the success rate of pulpotomies performed on permanent teeth, comparing the use of ProRoot MTA with that of calcium hydroxide and other bioceramic materials. METHODS: A comprehensive search was conducted in several electronic databases, including PubMed, Cochrane Library, Scopus, Web of Science, Embase and Science Direct until December 2022. The search was guided by PICOS criteria, including only randomized clinical trials (RCTs) that evaluated the success rate of pulpotomy treatments in permanent teeth using ProRoot MTA in comparison to calcium hydroxide and other bioceramic materials. The quality of the included studies was assessed using the RoB-2 tool to evaluate the risk of bias, and relevant data were extracted and analysed in RevMan software 5.3 using fixed-effect models. The GRADE tool was used to determine the overall quality of evidence. RESULTS: The initial search retrieved 1072 studies and, after eliminating duplicates, 677 studies were screened and 28 studies were considered for eligibility. In the final selection process, 16 studies were included in the systematic review, with 10 being determined as having a high risk of bias. Pulpotomy showed an overall mean success rate of 92% after 1 year. The meta-analysis indicated a significantly higher success rate for pulpotomies utilizing MTA in comparison with calcium hydroxide, while no significant difference was seen between MTA and calcium-enriched mixture (CEM) or Biodentine. The GRADE assessment revealed an overall low level of evidence for the included studies. DISCUSSION: Most randomized controlled trials exhibited a significant absence of control over confounding factors. CONCLUSIONS: This systematic review and meta-analysis demonstrate that pulpotomy is a highly effective treatment for managing permanent teeth. The results indicate that the success rate of pulpotomy using ProRoot MTA is significantly higher than when using calcium hydroxide. However, the certainty of evidence supporting these findings is low, and there is a need for well-designed RCTs to assess the long-term outcomes of pulpotomy using newer bioceramic materials. REGISTRATION: This systematic review was registered in the PROSPERO database (registration number CRD42023393970).


Asunto(s)
Hidróxido de Calcio , Pulpotomía , Humanos , Hidróxido de Calcio/uso terapéutico , Pulpotomía/métodos , Calcio , Compuestos de Aluminio/uso terapéutico , Combinación de Medicamentos , Óxidos/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Compuestos de Calcio/uso terapéutico , Resultado del Tratamiento , Silicatos/uso terapéutico
11.
J Endod ; 49(6): 730-734, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37004792

RESUMEN

INTRODUCTION: This report aims to communicate the discovery of a novel anatomy in a 3-rooted maxillary second molar, named as palato-mesiobuccal canal. METHODS: The tooth selected for this report was found incidentally as a result of a study on extracted maxillary molars that was being conducted for an unrelated purpose and involved hundreds of teeth. This 3-rooted maxillary second molar was scanned using a micro-computed tomography device set at a pixel size of 13.68 µm. The images were reconstructed with previously tested parameters resulting in the acquisition of 1655 axial cross-sections. Three-dimensional (3D) models of the internal and external anatomies were generated in Standard Tessellation Language (STL) format and were texturized to simulate the pulp tissue. The inner structure of the tooth was analyzed through the axial cross sections and the 3D volume was qualitatively evaluated. RESULTS: The analysis of the 3D models revealed that the maxillary second molar under examination has 3 independent roots and 4 root canals. Each root (mesiobuccal, distobuccal, and palatal) contains 1 canal, while the fourth canal follows a unique path, originating in the coronal third of the palatal canal and proceeding in a buccal direction ultimately exiting through an independent foramen at the apex of the mesiobuccal root, near the mesiobuccal canal. CONCLUSIONS: This brief communication reports the discovery of a novel anatomy in a 3-rooted maxillary second molar, named as palato-mesiobuccal canal, and provides important insights into the complexity of the root canal system in this group of teeth.


Asunto(s)
Cavidad Pulpar , Maxilar , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Microtomografía por Rayos X , Maxilar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/anatomía & histología , Tratamiento del Conducto Radicular , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología
12.
Int Endod J ; 56(6): 775-785, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36942476

RESUMEN

AIM: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability. METHODOLOGY: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%). RESULTS: All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05). CONCLUSIONS: Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.


Asunto(s)
Preparación del Conducto Radicular , Humanos , Aleaciones Dentales/química , Instrumentos Dentales , Diseño de Equipo , Ensayo de Materiales , Temperatura , Titanio/química , Torque
13.
Clin Oral Investig ; 27(5): 2427-2436, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36749411

RESUMEN

OBJECTIVE: This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability. MATERIALS AND METHODS: New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%. RESULTS: All instruments showed symmetrical cross sections with asymmetrical blades, no radial lands, no major defects, and an almost equiatomic nickel and titanium ratio. The highest R-phase start temperatures were observed with WaveOne Gold (46.1°C) and REX (44.8°C), while Reciproc Blue had the lowest R-phase start (34.5°C) and finish (20°C) temperatures. WaveOne Gold had the lowest time to fracture (169 s) and the highest maximum load (301.6 gf) (P <0.05). The maximum torque of Reciproc Blue (2.2 N.cm) and WaveOne Gold (2.1 N.cm) were similar (P >0.05), but lower than REX (2.6 N.cm) (P <0.05). No statistical differences were observed among instruments in the angle of rotation (P >0.05) and in the shaping ability in both mesial and distal canals (P >0.05). CONCLUSION: Although the overall design, temperature transition phases and mechanical behavior parameters were different among tested instruments, they were similar in terms of shaping ability. CLINICAL RELEVANCE: All tested heat-treated NiTi reciprocating systems showed similar shaping ability, without clinically significant errors.


Asunto(s)
Calor , Preparación del Conducto Radicular , Instrumentos Dentales , Diseño de Equipo , Titanio , Metalurgia , Ensayo de Materiales
14.
J Endod ; 49(5): 536-543, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36841384

RESUMEN

INTRODUCTION: This study aimed to evaluate the effects of root canal enlargement on the danger zone (DZ) of mandibular molars. METHODS: Thirty mesial roots of mandibular first molars were scanned in micro-computed tomography (S1). Canals were sequentially enlarged with rotary instruments up to sizes 30/0.04 (S2) and 30/0.06 (S3). The dentin thickness was measured at 0.1-mm intervals after each preparation step (n = 2964 slices). Root level and position of the DZ were also recorded. Data were compared using analysis of variance with Bonferroni pairwise comparison, Cochran's Q method, and Pearson's test (α = 5%). RESULTS: Comparing the specimens before (S1) and after (S2 and S3) preparations showed a significant reduction in the thickness of the DZ (P < .05), as well as between S2 and S3 steps (P < .05). At S1, the DZ was mostly located in the middle third of the root, but after preparation, it shifted toward the coronal direction (P < .05). Both S2 (P = .004, r = 0.508) and S3 (P = .004, r = 0.506) preparation steps showed a positive correlation between canal length and the root level of the DZ. At S1, the DZ was positioned toward the distal and mesial in 73.4% (n = 22) and 26.6% (n = 8) of the specimens, respectively. After S3, the number of specimens with DZ positioned toward the mesial aspect of the root significantly reduced to 3.3% (n = 1), whereas none of the specimens with DZ positioned toward the distal changed its position after root canal enlargements (P > .05). CONCLUSION: Overall, the enlargement of mesial canals of mandibular first molars with final instruments sizes 30/0.04 and 30/0.06 affected the thickness, root level, and position of the DZ.


Asunto(s)
Dentina , Mandíbula , Microtomografía por Rayos X , Raíz del Diente/diagnóstico por imagen , Cavidad Pulpar/diagnóstico por imagen , Preparación del Conducto Radicular
15.
J Endod ; 49(5): 487-495, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36848949

RESUMEN

INTRODUCTION: This study aimed to compare the in vivo accuracy and precision of 3 electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomographic (micro-CT) technology. METHODS: After access preparation of 23 necrotic or vital teeth from 5 patients, canals were negotiated, and hand files were used to determine the position of the foramen with 3 EALs: Propex Pixi (Dentsply Maillefer, Ballaigues, Switzerland), Woodpex III (Woodpecker Medical Instrument Co, Guilin, China), and Root ZX II (J Morita, Tokyo, Japan). After fixing the silicon stop to the file, teeth were extracted and scanned in a micro-CT device with and without the instrument inserted into the canal. Data sets were coregistered, and the accuracy and precision of the EALs were determined at a tolerance level of ±0.5 mm by measuring the distance from the tip of the instruments to a tangential line crossing the margins of the foramen. Statistical comparisons were performed using Friedman with post hoc related samples sign and Spearman tests (α = 5%). RESULTS: A significant difference was detected comparing the accuracy of Root ZX II (100%), Woodpex III (86.96%), and Propex Pixi (52.17%) (P < .05). There was a lack of significance in the relationship between the pulp status and the accuracy of the tested EALs (P > .05). Propex Pixi was significantly less precise than Root ZX II (P < .05), whereas no difference was found between Woodpex III and Root ZX II or Propex Pixi (P > .05). CONCLUSIONS: EALs presented similar precision, but Woodpex III and Root ZX II showed better accuracy to determine the position of the apical major foramen than Propex Pixi.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Cavidad Pulpar/diagnóstico por imagen , Odontometría , Ápice del Diente/diagnóstico por imagen , Electrónica
16.
Int Endod J ; 55(11): 1262-1273, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35993556

RESUMEN

AIM: To evaluate the effects of progressive root canal enlargements on the unprepared surface area and remaining dentine thickness of three-rooted maxillary first premolars with different root configurations. METHODOLOGY: Thirty three-rooted maxillary first premolars with three root configurations (n = 10) were selected and scanned in a micro-CT device. The root canals were sequentially enlarged with rotary instruments sizes 30.02 (step 1), 30.04 (step 2) and 30.06 (step 3). After each step, a new scan was taken. Analysed parameters included morphometric measurements (length, volume and surface area), number of static voxels and minimal dentine thickness. Statistical analyses were performed with one-way anova post hoc Tukey tests and paired sample t-test at a significance level of 5%. RESULTS: No statistical differences were observed amongst groups regarding the morphometric parameters and static voxels (p > .05). The minimal dentine thickness of the distobuccal root significantly changed depending on the root configuration (p < .05), whilst no differences were observed in the other roots (p > .05). A great variation in the position of the minimal dentine thickness was observed after preparation. Overall, mean percentage reduction in dentine thickness was higher in the buccal roots than in the palatal root (p < .05). In the mesiobuccal and distobuccal root, the number of slices with minimal dentine thickness lower than 0.05 mm increases 2 to 3 times and 3 to 4 times, respectively, from steps 1 to 3. CONCLUSIONS: Instruments sizes 30.02 and 30.04 can be safely and effectively used to enlarge the buccal and palatal canals of three-rooted maxillary first premolars.


Asunto(s)
Cavidad Pulpar , Maxilar , Diente Premolar/diagnóstico por imagen , Cavidad Pulpar/diagnóstico por imagen , Dentina/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Preparación del Conducto Radicular , Raíz del Diente/diagnóstico por imagen , Microtomografía por Rayos X
17.
Materials (Basel) ; 15(15)2022 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-35955223

RESUMEN

This study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.04), and TruNatomy (26/0.04v) instruments (n = 41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. The results were compared using one-way ANOVA, post hoc Tukey, and Kruskal−Wallis tests, with a significance level set at 5%. All instruments showed symmetrical cross-sections, with asymmetrical blades, no radial lands, no major defects, and almost equiatomic nickel−titanium ratios. Differences were noted in the number of blades, helical angles, cross-sectional design, and tip geometry. The Genius Proflex and the TruNatomy instruments had the highest and lowest R-phase start and finish temperatures, as well as the highest and lowest time and cycles to fracture (p < 0.05), respectively. The TruNatomy had the highest flexibility (p < 0.05), while no differences were observed between the Genius Proflex and the Vortex Blue (p > 0.05). No differences among tested systems were observed regarding the maximum torque, angle of rotation prior to fracture, and shaping ability (p > 0.05). The instruments showed similarities and differences in their design, metallurgy, and mechanical properties. However, their shaping ability was similar, without any clinically significant errors. Understanding these characteristics may help clinicians to make decisions regarding which instrument to choose for a particular clinical situation.

18.
Int Endod J ; 55(7): 795-807, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35383977

RESUMEN

AIM: To assess the interfacial adaptation (gap-containing areas) of two root canal sealers (EndoSequence BC Sealer and AH Plus) to a conventional gutta-percha (GP) cone (GP-sealer interface) in oval-shaped canals filled using the single cone technique. METHODOLOGY: Sixteen teeth with oval-shaped canals were selected, scanned in a micro-computed tomographic device, and pair-matched according to the volume, aspect ratio and configuration of root canals. Root canals were then sequentially prepared with WaveOne Gold Primary and Large instruments, followed by filling with WaveOne Large GP points associated with either the premixed calcium-silicate EndoSequence BC Sealer or the epoxy resin-based AH Plus sealer (n = 8 per group) using the single cone technique. After 7 days stored in phosphate-buffered saline solution at 37°C, the specimens were rescanned and the reconstructed images segmented in order to differentiate the filling materials (sealer and GP cone) to the dentine. A total of 453 cross-sectional slices were assessed and categorized according to the presence or absence of gaps at the GP-sealer interface. Mann-Whitney U-test verified the differences between groups and were considered significant at alpha = 5%. RESULTS: Gaps were non-homogenously distributed in two-dimensional axial cross-section images and none of the specimens showed completely gap-free areas along the entire GP-sealer interface. Root canals filled with EndoSequence BC Sealer and AH Plus displayed 171 (37.75%) and 136 (30.02%) slices with gaps in the GP-sealer interface and these frequencies were statistically significant (p = .000). CONCLUSIONS: Although none of the specimens had a gap-free area along the entire GP-sealer interface, oval canals filled with AH Plus showed less gaps than the ones filled with EndoSequence BC Sealer.


Asunto(s)
Gutapercha , Materiales de Obturación del Conducto Radicular , Estudios Transversales , Cavidad Pulpar/diagnóstico por imagen , Resinas Epoxi , Ensayo de Materiales , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Microtomografía por Rayos X
19.
Int Endod J ; 55 Suppl 2: 384-445, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35226760

RESUMEN

Canal filling materials and techniques have been one of the most studied topics in Endodontics. A simple search using the mesh term "root canal filling" in PubMed revealed more than 11 000 articles, an impressive number that is much higher than "root canal disinfection" (5544 articles) or even the popular "root canal preparation" (8527 articles). The overriding importance attributed to root filling procedures is not merely intuitive. It derived from the appealing relevance given by the appearance of the white lines in common radiographs grounded on retrospective clinical data that had identified the quality of a root filling as one of the major causes of treatment failure (lack of healing). Since the publication of the Washington study, impressive efforts have been made for the release of new materials and techniques, as well as, for the development of a plethora of laboratory methods to assess the quality of root filling procedures. This narrative review aims to address and discuss the most relevant laboratory methods to assess the root canal filling. As filling quality improvements have not translated into higher success rates, as reported in longitudinal clinical studies, more than to deliver a simple methodology-based review, this paper aims to present an in-depth critical view on the assessment of laboratory methods used to study the filling materials and techniques. Recent data indicate that the long-term dimensional stability/degradation over time of endodontic sealers plays a central role in the treatment outcome. In this context, laboratory methods should be developed focusing on predicting, at least to some degree, the long-term clinical behaviour of root canal fillings, rather than simply ranking different materials or techniques.


Asunto(s)
Cavidad Pulpar , Materiales de Obturación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Modelos Teóricos , Estudios Retrospectivos , Materiales de Obturación del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/métodos
20.
Int Endod J ; 55 Suppl 3: 531-587, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35100441

RESUMEN

In the last decades, the move of medicine towards minimally invasive treatments is notorious and scientifically grounded. As dentistry naturally follows in its footsteps, minimal access preparation have also becume a trend topic in the endodontic field. This procedure aims to maximize preservation of dentine tissue backed up by the idea that this is an effective way to reduce the incidence of post-treatment tooth fracture. However, with the assessment of the body of evidence on this topic, it is possible to observe some key points (a) the demand for nomenclature standardization, (b) the requirement of specific tools such as ultra-flexible instruments, visual magnification, superior illumination, and three-dimensional imaging technology, (c) minimally invasive treatment does not seem to affect orifice location and mechanical preparation when using adequate armamentarium, but it (d) may impair adequate canal cleaning, disinfection and filling procedures, and also (e) it displays contradictory results regarding the ability to increase the tooth strengthen compared to the traditional access cavity. In spite of that, it is undeniable that methodological flaws of some benchtop studies using extracted teeth may be responsible for the conflicting data, thus triggering the need for more sophisticated devices/facilities and specifically designed research in an attempt to make clear the role of the access size/design on long-term teeth survival. Moreover, it is inevitable that a clinical approach such as minimal endodontic access cavities that demands complex tools and skilled and experienced operators bring to the fore doubts on its educational impact mainly when confronted with the conflicting scientific output, ultimately provoking a cost-benefit analysis of its implementation as a routine technique. In addition, this review discusses the ongoing scientific and clinical status of minimally invasive access cavities aiming to input an in-depth and unbiased view over the rationale behind them, uncovering not only the related conceptual and scientific flaws but also outlining future directions for research and clinical practices. The conclusions attempt to skip from passionate disputes highlighting the current body of evidence as weak and incomplete to guide decision making, demanding the development of a close-to-in situ laboratory model or a large and well-controlled clinical trial to solve this matter.


Asunto(s)
Caries Dental , Fracturas de los Dientes , Cavidad Pulpar , Desinfección , Humanos , Preparación del Conducto Radicular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA