Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Neuroradiol J ; 32(5): 317-327, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31282311

RESUMEN

PURPOSE: The purpose of this preliminary study is to apply diffusional kurtosis imaging to assess the early response of recurrent glioblastoma to bevacizumab treatment. METHODS: This prospective cohort study included 10 patients who had been diagnosed with recurrent glioblastoma and scheduled to receive bevacizumab treatment. Diffusional kurtosis images were obtained from all the patients 0-7 days before (pre-bevacizumab) and 28 days after (post-bevacizumab) initiating bevacizumab treatment. The mean, 10th, and 90th percentile values were derived from the histogram of diffusional kurtosis imaging metrics in enhancing and non-enhancing lesions, selected on post-contrast T1-weighted and fluid-attenuated inversion recovery images. Correlations of imaging measures with progression-free survival and overall survival were evaluated using Spearman's rank correlation coefficient. The significance level was set at P < 0.05. RESULTS: Higher pre-bevacizumab non-enhancing lesion volume was correlated with poor overall survival (r = -0.65, P = 0.049). Higher post-bevacizumab mean diffusivity and axial diffusivity (D∥, D∥10% and D∥90%) in non-enhancing lesions were correlated with poor progression-free survival (r = -0.73, -0.83, -0.71 and -0.85; P < 0.05). Lower post-bevacizumab axial kurtosis (K∥10%) in non-enhancing lesions was correlated with poor progression-free survival (r = 0.81, P = 0.008). CONCLUSIONS: This preliminary study demonstrates that diffusional kurtosis imaging metrics allow the detection of tissue changes 28 days after initiating bevacizumab treatment and that they may provide information about tumor progression.


Asunto(s)
Antineoplásicos Inmunológicos/uso terapéutico , Bevacizumab/uso terapéutico , Neoplasias Encefálicas/tratamiento farmacológico , Glioblastoma/tratamiento farmacológico , Recurrencia Local de Neoplasia/tratamiento farmacológico , Adulto , Anciano , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Imagen de Difusión por Resonancia Magnética , Femenino , Glioblastoma/patología , Glioblastoma/cirugía , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/cirugía , Cuidados Posoperatorios/métodos , Estudios Prospectivos , Resultado del Tratamiento
2.
IEEE J Transl Eng Health Med ; 5: 3800204, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29285420

RESUMEN

Qualitative assessments of the blink reflex are used clinically to assess neurological status in critical care, operating room, and rehabilitative settings. Despite decades of literature supporting the use of quantitative measurements of the blink reflex in the evaluation of multiple neurological disorders, clinical adoption has failed. Thus, there remains an unmet clinical need for an objective, portable, non-invasive metric of neurological health that can be used in a variety of settings. We have developed a high-speed videography-based device to trigger, record, and analyze a blink reflex. A pilot study was performed to compare the device's measurements to the published literature of electromyographic measurements, currently the gold standard. The study results indicate that the device is a viable tool to obtain fast, objective, and quantitative metrics of a blink reflex, and has promise as a non-invasive diagnostic assessment of neurological health.

3.
Radiology ; 276(3): 706-14, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25786157

RESUMEN

PURPOSE: To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. MATERIALS AND METHODS: By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. RESULTS: Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). CONCLUSION: The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.


Asunto(s)
Vasos Coronarios , Procesamiento de Imagen Asistido por Computador , Stents , Tomografía Computarizada por Rayos X , Algoritmos , Fantasmas de Imagen , Diseño de Prótesis
4.
Med Image Anal ; 13(3): 519-29, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19332378

RESUMEN

Creation of a transjugular intrahepatic portosystemic shunt (TIPS) requires passage of a needle toward a moving target that is only seen transiently by X-ray prior to needle passage. Intraoperative, 3D target localization would facilitate target access and improve the safety of the procedure. The clinical assumption is that patients undergoing the TIPS procedure possess rigid, cirrhotic livers that undergo only intraoperative translation without significant deformation or rotation. Based upon this assumption, we hypothesize that the position of any unseen, 3D target point within the liver can be determined intraoperatively by precalculation of the relative positions of the target point to a different 3D point that can be tracked intraoperatively. This paper examines this hypothesis using intraoperatively acquired, biplane, X-ray images of seven patients. In six, we tracked the effects of cardiac and respiratory motion, and in three the effects of needle pressure. Methods involved reconstruction of 3D vessel bifurcation and other trackable intrahepatic points from biplane angiograms, measurement of liver deformation by examining changing distances between these 3D points over time, and comparison of expected to actual displacements of these points with respect to a fixed reference point in the liver. We conclude that, for the rigid livers associated with patients undergoing TIPS, that there is less intraoperative deformation than previously reported by other groups addressing healthy liver deformation, and that the location of an unseen target can be predicted within 3mm accuracy.


Asunto(s)
Venas Hepáticas/diagnóstico por imagen , Venas Hepáticas/cirugía , Vena Porta/diagnóstico por imagen , Vena Porta/cirugía , Derivación Portosistémica Intrahepática Transyugular/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Angiografía/métodos , Inteligencia Artificial , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos
5.
J Agric Food Chem ; 54(21): 8244-52, 2006 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-17032035

RESUMEN

Understanding how the environment and production and cultivation practices influence the composition and quality of food crops is fundamental to the production of high-quality nutritious foods. In this 3-year study, total phenolics, percent soluble solids, ascorbic acid, and the flavonoid aglycones quercetin, kaempferol, and luteolin were measured in two varieties of tomato (Lycopersicon esculentum L. cv. Ropreco and Burbank) and two varieties of bell peppers (Capsicum annuum L. cv. California Wonder and Excalibur) grown by certified organic and conventional practices in a model system. Significantly higher levels of percent soluble solids (17%), quercetin (30%), kaempferol (17%), and ascorbic acid (26%) were found in Burbank tomatoes (fresh weight basis; FWB), whereas only levels of percent soluble solids (10%) and kaempferol (20%) were significantly higher in organic Ropreco tomatoes (FWB). Year-to-year variability was significant, and high values from 2003 influenced the 3-year average value of quercetin reported for organic Burbank tomatoes. Burbank tomatoes generally had higher levels of quercetin, kaempferol, total phenolics, and ascorbic acid as compared to Ropreco tomatoes. Bell peppers were influenced less by environment and did not display cropping system differences.


Asunto(s)
Antioxidantes/análisis , Capsicum/química , Alimentos Orgánicos/análisis , Valor Nutritivo , Control de Calidad , Solanum lycopersicum/química , Ácido Ascórbico/análisis , Frutas/química , Quempferoles/análisis , Quercetina/análisis
6.
Artículo en Inglés | MEDLINE | ID: mdl-17354829

RESUMEN

We have developed a novel model-to-image registration technique which aligns a 3-dimensional model of vasculature with two semiorthogonal fluoroscopic projections. Our vascular registration method is used to intra-operatively initialize the alignment of a catheter and a preoperative vascular model in the context of image-guided TIPS (Transjugular, Intrahepatic, Portosystemic Shunt formation) surgery. Registration optimization is driven by the intensity information from the projection pairs at sample points along the centerlines of the model. Our algorithm shows speed, accuracy and consistency given clinical data.


Asunto(s)
Imagenología Tridimensional/métodos , Modelos Biológicos , Derivación Portosistémica Intrahepática Transyugular/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Técnica de Sustracción , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Inteligencia Artificial , Simulación por Computador , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/cirugía , Venas Hepáticas/diagnóstico por imagen , Venas Hepáticas/cirugía , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
8.
Artículo en Inglés | MEDLINE | ID: mdl-16685965

RESUMEN

Accurate 3D/2D vessel registration is complicated by issues of image quality, occlusion, and other problems. This study performs a quantitative comparison of 3D/2D vessel registration in which vessels segmented from preoperative CT or MR are registered with biplane x-ray angiograms by either a) simultaneous two-view registration with advance calculation of the relative pose of the two views, or b) sequential registration with each view. We conclude on the basis of phantom studies that, even in the absence of image errors, simultaneous two-view registration is more accurate than sequential registration. In more complex settings, including clinical conditions, the relative accuracy of simultaneous two-view registration is even greater.


Asunto(s)
Algoritmos , Angiografía/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Técnica de Sustracción , Angiografía/instrumentación , Inteligencia Artificial , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA