Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 13(7): 804-11, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9802669

RESUMEN

In this study, 92 primary total hip arthroplasties were performed in 83 patients using a porous-coated, dual-radius, cementless, acetabular component. All hips underwent line-to-line dome reaming with press-fit implantation that was judged to have complete bone contact. This acetabular shell provides a 1-mm oversized peripheral rim, which adds excellent initial stability while allowing complete bone contact in all hips. No fractures occurred. In 83% of hips, adjunctive screw fixation was not necessary. At a minimum of 4 years, follow-up, there were no revisions, no acetabular migration, one case of acetabular erosion consistent with osteolysis, and the average Harris Hip Score was 95. The design features of this new acetabular component have provided excellent fixation with complete initial bone contact, resulting in satisfactory intermediate clinical and radiographic results. The design provides excellent peripheral stability and complete bone contact.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles Revestidos , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Polietilenos , Porosidad , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Resultado del Tratamiento
2.
J Arthroplasty ; 12(4): 365-72, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9195311

RESUMEN

Bone ingrowth into uncemented femoral implants with proximal porous coatings has been designed to avoid proximal stress shielding and preserve femoral strength. Dual-energy x-ray absorptiometry allows repeated quantitative analysis of anteroposterior scans of the proximal femur. By use of dual-energy x-ray absorptiometry and qualitative radiographic changes, 31 total hip arthroplasties with an individually designed, proximally porous-coated prosthesis were evaluated after surgery and at intervals up to 2 years. All implants appeared to achieve successful bone ingrowth and subsequent remodeling. At the most proximal level around the neck osteotomy, the postoperative loss of bone density at 6 months was -14.5%, which persisted at 24 months with -11.6%. At the level of the distal portion of the porous coating in the lower metaphysis, the density change was -8.7%, but bone had remodeled at 24 months with a change in density of only -1.0% compared with the immediate postoperative scan. With a design that results in reliable proximal ingrowth, this study predicts that after an initial decline in bone density, a positive bone remodeling response occurs that could lead to long-term stable fixation of the femoral implant.


Asunto(s)
Absorciometría de Fotón/métodos , Densidad Ósea , Fémur/fisiología , Cementos para Huesos , Femenino , Fémur/diagnóstico por imagen , Estudios de Seguimiento , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Modelos Estructurales , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA