Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 219
Filtrar
1.
EuroIntervention ; 20(17): e1076-e1085, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39219361

RESUMEN

BACKGROUND: Large datasets of transcatheter aortic valve implantation (TAVI) for pure aortic valve regurgitation (PAVR) are scarce. AIMS: We aimed to report procedural safety and long-term clinical events (CE) in a contemporary cohort of PAVR patients treated with new-generation devices (NGD). METHODS: Patients with grade III/IV PAVR enrolled in the FRANCE-TAVI Registry were selected. The primary safety endpoint was technical success (TS) according to Valve Academic Research Consortium 3 criteria. The co-primary endpoint was defined as a composite of mortality, heart failure hospitalisation and valve reintervention at last follow-up. RESULTS: From 2015 to 2021, 227 individuals (64.3% males, median age 81.0 [interquartile range {IQR} 73.5-85.0] years, with EuroSCORE II 6.0% [IQR 4.0-10.9]) from 41 centres underwent TAVI with NGD, using either self-expanding (55.1%) or balloon-expandable valves (44.9%; p=0.50). TS was 85.5%, with a non-significant trend towards increased TS in high-volume activity centres. A second valve implantation (SVI) was needed in 8.8% of patients, independent of valve type (p=0.82). Device size was ≥29 mm in 73.0% of patients, post-procedure grade ≥III residual aortic regurgitation was rare (1.2%), and the permanent pacemaker implantation (PPI) rate was 36.0%. At 30 days, the incidences of mortality and reintervention were 8.4% and 3.5%, respectively. The co-primary endpoint reached 41.6% (IQR 34.4-49.6) at 1 year, increased up to 61.8% (IQR 52.4-71.2) at 4 years, and was independently predicted by TS, with a hazard ratio of 0.45 (95% confidence interval: 0.27-0.76); p=0.003. CONCLUSIONS: TAVI with NGD in PAVR patients is efficient and reasonably safe. Preventing the need for an SVI embodies the major technical challenge. Larger implanted valves may have limited this complication, outweighing the increased risk of PPI. Despite successful TAVI, PAVR patients experience frequent CE at long-term follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Factores de Riesgo , Francia
3.
Eur Heart J ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189413

RESUMEN

This report from the European Society of Cardiology (ESC) Atlas Project updates and expands upon the 2021 report in presenting cardiovascular disease (CVD) statistics for the ESC member countries. This paper examines inequalities in cardiovascular healthcare and outcomes in ESC member countries utilizing mortality and risk factor data from the World Health Organization and the Global Burden of Disease study with additional economic data from the World Bank. Cardiovascular healthcare data were collected by questionnaire circulated to the national cardiac societies of ESC member countries. Statistics pertaining to 2022, or latest available year, are presented. New material in this report includes contemporary estimates of the economic burden of CVD and mortality statistics for a range of CVD phenotypes. CVD accounts for 11% of the EU's total healthcare expenditure. It remains the most common cause of death in ESC member countries with over 3 million deaths per year. Proportionately more deaths from CVD occur in middle-income compared with high-income countries in both females (53% vs. 34%) and males (46% vs. 30%). Between 1990 and 2021, median age-standardized mortality rates (ASMRs) for CVD decreased by median >50% in high-income ESC member countries but in middle-income countries the median decrease was <12%. These inequalities between middle- and high-income ESC member countries likely reflect heterogeneous exposures to a range of environmental, socioeconomic, and clinical risk factors. The 2023 survey suggests that treatment factors may also contribute with middle-income countries reporting lower rates per million of percutaneous coronary intervention (1355 vs. 2330), transcatheter aortic valve implantation (4.0 vs. 153.4) and pacemaker implantation (147.0 vs. 831.9) compared with high-income countries. The ESC Atlas 2023 report shows continuing inequalities in the epidemiology and management of CVD between middle-income and high-income ESC member countries. These inequalities are exemplified by the changes in CVD ASMRs during the last 30 years. In the high-income ESC member countries, ASMRs have been in steep decline during this period but in the middle-income countries declines have been very small. There is now an important need for targeted action to reduce the burden of CVD, particularly in those countries where the burden is greatest.

4.
EuroIntervention ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39207816

RESUMEN

The percutaneous treatment of structural, valvular, and non-valvular heart disease (SHD) is rapidly evolving. The Core Curriculum (CC) proposed by the EAPCI describes the knowledge, skills, and attitudes that define competency levels required by newly trained SHD interventional cardiologists (IC) and provides guidance for training centres. SHD ICs are cardiologists who have received complete interventional cardiology training. They are multidisciplinary team specialists who manage adult SHD patients from diagnosis to follow-up and perform percutaneous procedures in this area. They are competent in interpreting advanced imaging techniques and master planning software. The SHD ICs are expected to be proficient in the aortic, mitral, and tricuspid areas. They may have selective skills in either the aortic area or mitral/tricuspid areas. In this case, they must still have common transversal competencies in the aortic, mitral, and tricuspid areas. Additional SHD domain competencies are optional. Completing dedicated SHD training, aiming for full aortic, mitral, and tricuspid competencies, requires at least 18 months. For full training in the aortic area, with basic competencies in mitral/tricuspid areas, the training can be reduced to 1 year. The same is true for training in the mitral/tricuspid area, with competencies in the aortic area. The SHD IC CC promotes excellence and homogeneous training across Europe and is the cornerstone of future certifications and patient protection. It may be a reference for future CC for national associations and other SHD specialities, including imaging and cardiac surgery.

6.
Eur J Clin Invest ; 54(9): e14241, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38767226

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Falla de Prótesis , Masculino , Anciano
7.
Lancet ; maio.2024.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1555077

RESUMEN

BACKGROUND Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1•5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2­4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10•44% and assuming an event rate of 26•10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80•0 years (SD 5•7) for those treated with the Myval THV and 80•4 years (5•4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2•6% [IQR 1•7­4•0] vs contemporary 2•6% [1•7­4•0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of ­2•3% (one-sided upper 95% CI 3•8, pnon-inferiority<0•0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days.

8.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38795719

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
10.
Eur J Heart Fail ; 26(8): 1850-1860, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38812292

RESUMEN

AIMS: Data on the prognostic impact of residual tricuspid regurgitation (TR) after tricuspid transcatheter edge-to-edge repair (T-TEER) are scarce. The aim of this analysis was to evaluate 2-year survival and symptomatic outcomes of patients in relation to residual TR after T-TEER. METHODS AND RESULTS: Using the large European Registry of Transcatheter Repair for Tricuspid Regurgitation (EuroTR registry) we investigated the impact of residual TR on 2-year all-cause mortality and New York Heart Association (NYHA) functional class at follow-up. The study further identified predictors for residual TR ≥3+ using a logistic regression model. The study included a total of 1286 T-TEER patients (mean age 78.0 ± 8.9 years, 53.6% female). TR was successfully reduced to ≤1+ in 42.4%, 2+ in 40.0% and 3+ in 14.9% of patients at discharge, while 2.8% remained with TR ≥4+ after the procedure. Residual TR ≥3+ was an independent multivariable predictor of 2-year all-cause mortality (hazard ratio 2.06, 95% confidence interval 1.30-3.26, p = 0.002). The prevalence of residual TR ≥3+ was four times higher in patients with higher baseline TR (vena contracta >11.1 mm) and more severe tricuspid valve tenting (tenting area >1.92 cm2). Of note, no survival difference was observed in patients with residual TR ≤1+ versus 2+ (76.2% vs. 73.1%, p = 0.461). The rate of NYHA functional class ≥III at follow-up was significantly higher in patients with residual TR ≥3+ (52.4% vs. 40.5%, p < 0.001). Of note, the degree of TR reduction significantly correlated with the extent of symptomatic improvement (p = 0.012). CONCLUSIONS: T-TEER effectively reduced TR severity in the majority of patients. While residual TR ≥3+ was associated with worse outcomes, no differences were observed for residual TR 1+ versus 2+. Symptomatic improvement correlated with the degree of TR reduction.


Asunto(s)
Cateterismo Cardíaco , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/epidemiología , Femenino , Masculino , Anciano , Cateterismo Cardíaco/métodos , Válvula Tricúspide/cirugía , Europa (Continente)/epidemiología , Pronóstico , Resultado del Tratamiento , Anciano de 80 o más Años , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Tasa de Supervivencia/tendencias
11.
Circ Cardiovasc Interv ; 17(4): e013675, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38626079

RESUMEN

BACKGROUND: Primary percutaneous coronary intervention (pPCI) has improved clinical outcomes in patients with ST-segment-elevation myocardial infarction. However, as many as 50% of patients still have suboptimal myocardial reperfusion and experience extensive myocardial necrosis. The PiCSO-AMI-I trial (Pressure-Controlled Intermittent Coronary Sinus Occlusion-Acute Myocardial Infarction-I) evaluated whether PiCSO therapy can further reduce myocardial infarct size (IS) in patients undergoing pPCI. METHODS: Patients with anterior ST-segment-elevation myocardial infarction and Thrombolysis in Myocardial Infarction flow 0-1 were randomized at 16 European centers to PiCSO-assisted pPCI or conventional pPCI. The PiCSO Impulse Catheter (8Fr balloon-tipped catheter) was inserted via femoral venous access after antegrade flow restoration of the culprit vessel and before proceeding with stenting. The primary end point was the difference in IS (expressed as a percentage of left ventricular mass) at 5 days by cardiac magnetic resonance. Secondary end points were the extent of microvascular obstruction and intramyocardial hemorrhage at 5 days and IS at 6 months. RESULTS: Among 145 randomized patients, 72 received PiCSO-assisted pPCI and 73 conventional pPCI. No differences were observed in IS at 5 days (27.2%±12.4% versus 28.3%±11.45%; P=0.59) and 6 months (19.2%±10.1% versus 18.8%±7.7%; P=0.83), nor were differences between PiCSO-treated and control patients noted in terms of the occurrence of microvascular obstruction (67.2% versus 64.6%; P=0.85) or intramyocardial hemorrhage (55.7% versus 60%; P=0.72). The study was prematurely discontinued by the sponsor with no further clinical follow-up beyond 6 months. However, up to 6 months of PiCSO use appeared safe with no device-related adverse events. CONCLUSIONS: In this prematurely discontinued randomized trial, PiCSO therapy as an adjunct to pPCI did not reduce IS when compared with conventional pPCI in patients with anterior ST-segment-elevation myocardial infarction. PiCSO use was associated with increased procedural time and contrast but no increase in adverse events up to 6 months. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03625869.


Asunto(s)
Seno Coronario , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Seno Coronario/diagnóstico por imagen , Circulación Coronaria , Resultado del Tratamiento , Estudios Prospectivos , Infarto del Miocardio/etiología , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/etiología , Intervención Coronaria Percutánea/efectos adversos , Hemorragia/etiología
12.
J Cardiol Cases ; 29(3): 116-119, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481646

RESUMEN

We report the case of a redo Ross surgery complicated by an ostial left circumflex occlusion requiring emergent percutaneous coronary intervention. The latter was complicated by coronary perforation treated by two covered stents with V-stenting technique. After immediate success, the clinical course was marked by acute stent thrombosis requiring emergent coronary bypass. Learning objectives: Ostial left circumflex perforation is a rare and potentially fatal complication that is challenging to manage. V stenting technique with two covered stents could be used as a life-saving procedure, but is associated with a high thrombotic risk.

13.
Am Heart J ; 270: 86-94, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38309610

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Puente de Arteria Coronaria , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
14.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
15.
Can J Cardiol ; 40(1): 31-39, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37660934

RESUMEN

BACKGROUND: There are dated and conflicting data about the optimal timing of initiation of P2Y12 inhibitors in elective percutaneous coronary intervention (PCI). Peri-PCI myocardial necrosis is associated with poor outcomes. We aimed to assess the impact of the P2Y12 inhibitor loading time on periprocedural myocardial necrosis in the population of the randomized Assessment of Loading With the P2Y12 Inhibitor Ticagrelor or Clopidogrel to Halt Ischemic Events in Patients Undergoing Elective Coronary Stenting (ALPHEUS) trial, which compared ticagrelor with clopidogrel in high-risk patients who received elective PCI. METHODS: The ALPHEUS trial divided 1809 patients into quartiles of loading time. The ALPHEUS primary outcome was used (type 4 [a or b] myocardial infarction or major myocardial injury) as well as the main secondary outcome (type 4 [a or b] myocardial infarction or any type of myocardial injury). RESULTS: Patients in the first quartile group (Q1) presented higher rates of the primary outcome (P = 0.01). When compared with Q1, incidences of the primary outcome decreased in patients with longer loading times (adjusted odds ratio [adjOR], 0.70 [0.52.-0.95]; P = 0.02 for Q2; adjOR 0.65 [0.48-0.88]; P < 0.01 for Q3; adjOR 0.66 [0.49-0.89]; P < 0.01 for Q4). Concordant results were found for the main secondary outcome. There was no interaction with the study drug allocated by randomization (clopidogrel or ticagrelor). Bleeding complications (any bleeding ranging between 4.9% and 7.3% and only 1 major bleeding at 48 hours) and clinical ischemic events were rare and did not differ among groups. CONCLUSIONS: In elective PCI, administration of the oral P2Y12 inhibitor at the time of PCI could be associated with more frequent periprocedural myocardial necrosis than an earlier administration. The long-term clinical consequences remain unknown.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Clopidogrel/uso terapéutico , Ticagrelor/uso terapéutico , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio/etiología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Resultado del Tratamiento
16.
Cardiovasc Revasc Med ; 59: 93-98, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37723011

RESUMEN

INTRODUCTION: Clinical events may occur after percutaneous coronary intervention (PCI), particularly in complex lesions and complex patients. The optimization of PCI result, using pressure guidewire and intracoronary imaging techniques, may reduce the risk of these events. The hypothesis of the present study is that the clinical outcome of patients with indication of PCI and coronary stent implantation that are at high risk of events can be improved with an unrestricted use of intracoronary tools that allow PCI optimization. METHODS AND ANALYSIS: Observational prospective multicenter international study, with a follow-up of 12 months, including 1064 patients treated with a cobalt­chromium everolimus-eluting stent. Inclusion criteria include any of the following: Lesion length > 28 mm; Reference vessel diameter < 2.5 mm or > 4.25 mm; Chronic total occlusion; Bifurcation with side branch ≥2.0 mm;Ostial lesion; Left main lesion; In-stent restenosis; >2 lesions stented in the same vessel; Treatment of >2 vessels; Acute myocardial infarction; Renal insufficiency; Left ventricular ejection fraction <30 %; Staged procedure. The control group will be comprised by a similar number of matched patients included in the "extended risk" cohort of the XIENCE V USA study. The primary endpoint will be the 1-year rate of target lesion failure (TLF) (composite of ischemia-driven TLR, myocardial infarction (MI) related to the target vessel, or cardiac death related to the target vessel). Secondary endpoints will include overall mortality, cardiovascular mortality, acute myocardial infarction, TVR, TLR, target vessel failure, and definitive or probable stent thrombosis at 1 year. IMPLICATIONS: The ongoing OPTI-XIENCE study will contribute to the growing evidence supporting the use of intra-coronary imaging techniques for stent optimization in patients with complex coronary lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Sirolimus , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
17.
JACC Basic Transl Sci ; 8(11): 1424-1435, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38093739

RESUMEN

Clonal hematopoiesis of indeterminate potential (CHIP) is considered as being a novel age-related risk factor for cardiovascular diseases. By capture-sequencing of a 67-gene panel, we established a large spectrum of CHIP in 258 patients with aortic valve stenosis undergoing transcatheter aortic valve replacement (TAVR) and assessed their association with long-term survival after TAVR. One or several CHIP variants in 35 genes were identified in 68% of the cohort, DNMT3A and TET2 being the 2 most frequently mutated genes. Patients carrying a TET2-CHIP-driver variant with low variant allele frequency (2%-10%) had a significant decrease in overall survival 5 years after TAVR.

18.
Arch Cardiovasc Dis ; 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37783602

RESUMEN

BACKGROUND: Obstructive coronary artery disease is the main cause of death worldwide. By tracking events and gaining feedback on patient management, the most relevant information is provided to public health services to further improve prognosis. AIMS: To create an inclusive and accurate registry of all percutaneous coronary intervention (PCI) procedures performed in France, to assess and improve the quality of care and create research incentives. Also, to describe the methodology of this French national registry of interventional cardiology, and present early key findings. METHODS: The France PCI registry is a multicentre observational registry that includes consecutive patients undergoing coronary angiography and/or PCI. The registry was set up to provide online data analysis and structured reports of PCI activity, including process of care measures and assessment of risk-adjusted outcomes in all French PCI centres that are willing to participate. More than 150 baseline data items, describing demographic status, PCI indications and techniques, and in-hospital and 1-year outcomes, are captured into local reporting software by medical doctors and local research technicians, with subsequent encryption and internet transfer to central data servers. Annual activity reports and scoring tools available on the France PCI website enable users to benchmark and improve clinical practices. External validation and consistency assessments are performed, with feedback of data completeness to centres. RESULTS: Between 01 January 2014 and 31 December 2022, participating centres increased from six to 47, and collected 364,770 invasive coronary angiograms and 176,030 PCIs, including 54,049 non-ST-segment elevation myocardial infarction cases and 31,631 ST-segment elevation myocardial infarction cases. Fifteen studies stemming from the France PCI registry have already been published. CONCLUSIONS: This fully electronic, daily updated, high-quality, low-cost, national registry is sustainable, and is now expanding. Merging with medicoeconomic databases and nested randomized scientific studies are ongoing steps to expand its scientific potential.

19.
Arch Cardiovasc Dis ; 116(12): 590-596, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37891058

RESUMEN

Vasospastic angina, also described as Prinzmetal angina, was first described as a variant form of angina at rest with transient ST-segment elevation; it is common and present in many clinical scenarios, including chronic and acute coronary syndromes, sudden cardiac death, arrhythmia and syncope. However, vasospastic angina remains underdiagnosed, and provocative tests are rarely performed. The gold-standard diagnostic approach uses invasive coronary angiography to induce coronary spasm using ergonovine, methylergonovine or acetylcholine as provocative stimuli. The lack of uniform protocol decreases the use and performance of these tests, accounting for vasospastic angina underestimation. This position paper from the French Coronary Atheroma and Interventional Cardiology Group (GACI) aims to review the indications for provocative tests, the testing conditions, drug protocols and positivity criteria.


Asunto(s)
Angina Pectoris Variable , Cardiología , Enfermedad de la Arteria Coronaria , Vasoespasmo Coronario , Placa Aterosclerótica , Humanos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasoespasmo Coronario/diagnóstico , Vasoespasmo Coronario/diagnóstico por imagen , Espasmo
20.
Circ Res ; 133(10): 826-841, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37883587

RESUMEN

BACKGROUND: Thrombocytopenia has been consistently described in patients with extracorporeal membrane oxygenation (ECMO) and associated with poor outcome. However, the prevalence and underlying mechanisms remain largely unknown, and a device-related role of ECMO in thrombocytopenia has been hypothesized. This study aims to investigate the mechanisms underlying thrombocytopenia in ECMO patients. METHODS: In a prospective cohort of 107 ECMO patients, we investigated platelet count, functions, and glycoprotein shedding. In an ex vivo mock circulatory ECMO loop, we assessed platelet responses and VWF (von Willebrand factor)-GP Ibα (glycoprotein Ibα) interactions at low- and high-flow rates, in the presence or absence of red blood cells. The clearance of human platelets subjected or not to ex vivo perfusion was studied using an in vivo transfusion model in NOD/SCID (nonobese diabetic/severe combined Immunodeficient) mice. RESULTS: In ECMO patients, we observed a time-dependent decrease in platelet count starting 1 hour after device onset, with a mean drop of 7%, 35%, and 41% at 1, 24, and 48 hours post-ECMO initiation (P=0.00013, P<0.0001, and P<0.0001, respectively), regardless of the type of ECMO. This drop in platelet count was associated with a decrease in platelet GP Ibα expression (before: 47.8±9.1 versus 24 hours post-ECMO: 42.3±8.9 mean fluorescence intensity; P=0.002) and an increase in soluble GP Ibα plasma levels (before: 5.6±3.3 versus 24 hours post-ECMO: 10.8±4.1 µg/mL; P<0.0001). GP Ibα shedding was also observed ex vivo and was unaffected by (1) red blood cells, (2) the coagulation potential, (3) an antibody blocking VWF-GP Ibα interaction, (4) an antibody limiting VWF degradation, and (5) supraphysiological VWF plasma concentrations. In contrast, GP Ibα shedding was dependent on rheological conditions, with a 2.8-fold increase at high- versus low-flow rates. Platelets perfused at high-flow rates before being transfused to immunodeficient mice were eliminated faster in vivo with an accelerated clearance of GP Ibα-negative versus GP Ibα-positive platelets. CONCLUSIONS: ECMO-associated shear forces induce GP Ibα shedding and thrombocytopenia due to faster clearance of GP Ibα-negative platelets. Inhibiting GP Ibα shedding could represent an approach to reduce thrombocytopenia during ECMO.


Asunto(s)
Trombocitopenia , Factor de von Willebrand , Humanos , Animales , Ratones , Factor de von Willebrand/metabolismo , Estudios Prospectivos , Ratones Endogámicos NOD , Ratones SCID , Plaquetas/metabolismo , Trombocitopenia/terapia , Trombocitopenia/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA