Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Heliyon ; 10(12): e33101, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39021971

RESUMEN

The main objective of this study was to evaluate the impact of the length and retention time of a tubular helical flow flocculator (THFF) on the elimination of turbidity and color from raw water, to obtain quality treated water for consumption in areas rural. For this, a large-scale field experimental system was used, the THFF was built with 4-inch diameter polyethylene hose and coupled to a sedimentation and filtration process. For the different experimental tests, aluminum sulfate was chosen as the coagulant. To find the optimal dose of coagulant, jar tests were previously carried out. For the tests the length of the THFF was varied (50 m and 75 m), flow rates of 0.25, 0.5, 0.75, 1 and 2 L/s and turbidity ranges of <10, 10-20, 21-50, 51-100 and > 100 NTU of raw water were tested. An evaluation of the hydraulic behavior of the THFF was carried out through an analysis of the temporal distribution curve of the concentration of a tracer, applying the Wolf-Resnick model. The average results revealed a haze and color removal efficiency of 98.07 % and 98.50 %, respectively. The residence time and velocity gradient exhibited variations in a range of 2.25-35.0 min and 3.64 to 56.94 s-1, respectively. It was evident that the operation and effectiveness of THFF are directly influenced by the turbidity of the raw water, the residence time and the velocity gradient. These findings indicate that THFF could play a valuable role as a flocculation unit in a purification system, mainly the existence of a plug-type flow was observed. The findings indicate that THFF, complemented by settling and filtration processes, could be a valuable tool for implementation in rural areas.

2.
Data Brief ; 54: 110336, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38586135

RESUMEN

This article presents a set of data obtained during the evaluation of a horizontal flow tubular flocculator for the provision of drinking water in developing communities. The HFTF is presented as an alternative technology to replace conventional flocculators, allowing high efficiency in the subsequent sedimentation and filtration processes. For obtaining the data, experimental tests were carried out using lengths of 68.4 m and 97.6 m for the HFTF, these lengths were combined with flow rates of 0.25, 0.5, 0.75, 1.0 and 2.0 L/s, as well as raw water turbidities of 10, 20, 50, 100 and 200 NTU. The data set generated from measurements and observations made during experimental field tests is detailed. The resulting data set covers the main parameters that determine the quality of drinking water, such as turbidity and colour, as well as flocculation efficiency data. The data from the experimental system were compared with a conventional treatment plant that has a baffle flocculator. Likewise, data on the retention time and velocity gradient are presented that allowed the hydraulic characteristics of the HFTF are evaluated. This data set has significant potential for reuse in future research and development related to water treatment technologies in developing community settings. Detailed data has been collected on various operating conditions of the HFTF, such as different lengths, water flow rates and turbidity levels, as well as measurements of key parameters such as turbidity, colour, flocculation efficiency, retention time and velocity gradient, these Data could be used in future research and development related to water treatment technologies. Furthermore, a comparison of data from the experimental system with a conventional treatment plant provides useful insight into the relative performance of different water treatment technologies, which could be of interest to researchers, system designers and public policymakers in the field of drinking water supply in developing communities.

3.
Sci Total Environ ; 917: 170353, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38296076

RESUMEN

Microplastics (MPs) are known for their ubiquity, having been detected in virtually any environmental compartment. However, indoor MPs concentrations are poorly studied despite being closely related to human exposure. The present study aims to evaluate the presence of MPs in settled atmospheric dust in 60 houses distributed in 12 districts of the metropolitan city of Lima, Peru, and investigate the influence of their geographical location and house characteristics. MPs concentration ranged from 0.01 to 33.9 MPs per mg of dust. Fibers and blue were the most frequent shape and color (98 % and 69 %, respectively). Also, 82 % of the particles were between 500 µm - 5 mm in size. A higher concentration of MPs was identified in the center-south of the city. The houses located on the highest floors (levels 4 to 13 to ground) displayed higher concentrations. MPs were primarily composed of polyester (PET), polypropylene (PP), and ethylene-vinyl acetate (EVA), among others. The polymers identified suggest that MPs derived from the fragmentation of components frequently found in houses, such as synthetic clothing, food storage containers, toys, carpets, floors, and curtains. The incorporation of MPs from the outside into dwellings is not ruled out. Future studies should evaluate the influence of consumption habits and housing characteristics on the abundance of MPs.


Asunto(s)
Microplásticos , Plásticos , Humanos , Polvo , Embalaje de Alimentos , Almacenamiento de Alimentos , Monitoreo del Ambiente
4.
Sci Rep ; 12(1): 16737, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36202880

RESUMEN

A total of 188,859 meteorological-PM[Formula: see text] data validated before (2019) and during the COVID-19 pandemic (2020) were used. In order to predict PM[Formula: see text] in two districts of South Lima in Peru, hourly, daily, monthly and seasonal variations of the data were analyzed. Principal Component Analysis (PCA) and linear/nonlinear modeling were applied. The results showed the highest annual average PM[Formula: see text] for San Juan de Miraflores (SJM) (PM[Formula: see text]-SJM: 78.7 [Formula: see text]g/m[Formula: see text]) and the lowest in Santiago de Surco (SS) (PM[Formula: see text]-SS: 40.2 [Formula: see text]g/m[Formula: see text]). The PCA showed the influence of relative humidity (RH)-atmospheric pressure (AP)-temperature (T)/dew point (DP)-wind speed (WS)-wind direction (WD) combinations. Cool months with higher humidity and atmospheric instability decreased PM[Formula: see text] values in SJM and warm months increased it, favored by thermal inversion (TI). Dust resuspension, vehicular transport and stationary sources contributed more PM[Formula: see text] at peak times in the morning and evening. The Multiple linear regression (MLR) showed the best correlation (r = 0.6166), followed by the three-dimensional model LogAP-LogWD-LogPM[Formula: see text] (r = 0.5753); the RMSE-MLR (12.92) exceeded that found in the 3D models (RMSE [Formula: see text]) and the NSE-MLR criterion (0.3804) was acceptable. PM[Formula: see text] prediction was modeled using the algorithmic approach in any scenario to optimize urban management decisions in times of pandemic.


Asunto(s)
Contaminantes Atmosféricos , COVID-19 , Contaminantes Atmosféricos/análisis , COVID-19/epidemiología , Polvo , Monitoreo del Ambiente/métodos , Humanos , Pandemias , Perú/epidemiología
5.
Case Stud Chem Environ Eng ; 2: 100049, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38620556

RESUMEN

This review goal is to reflect on the challenges and prospects for water quality in the face of the pandemic caused by the new SARS-CoV-2 coronavirus (COVID-19). Based on the information available so far, the detection of SARS-CoV-2 RNA in wastewater has raised interest in using it as an early warning method, to detect the resurgence of infections and to report the risk associated with contracting SARS-CoV-2 in contact with untreated water or inadequately treated wastewater is discharged. The wastewater-based epidemiological approach can be used as an early indicator of infection within a specific population. On the other hand, it is necessary to collect information from the managers of drinking water supply companies and professionals who are related to water quality, to know SARS-CoV-2 data and information, and its influence on drinking water quality. The basic purpose of this review article is to try to provide a valuable and quick reference guide to COVID-19. Important topics were discussed, such as detection of SARS-CoV-2 in wastewater in various parts of the world; wastewater screening to monitor COVID-19; persistence of SARS-CoV-2 in aquatic systems; the presence of SARS-CoV-2 in drinking water; clean water as a mechanism to deal with the COVID-19 pandemic; chlorine as a disinfectant to eliminate SARS-CoV-2 and damage to ecosystems by the use of chlorine. Currently does not exist extensive literature on the effectiveness of water and wastewater treatment processes that ensure the correct elimination of SARS-CoV-2. Excessive use of disinfectants such as chlorine is causing effects on the environment. This document highlights the need for further research to establish the behavior of the SARS-CoV-2 virus in aquatic systems. This study presents an early overview of the observed and potential impacts of COVID-19 on the environment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA