Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Knee ; 24(6): 1478-1484, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28970125

RESUMEN

BACKGROUND: It is commonly thought that balanced medial and lateral tibiofemoral joint gaps are essential, but the effect of joint laxity on clinical outcome after total knee arthroplasty (TKA) is unclear. It was hypothesised that medial joint laxity correlates with inferior patient satisfaction and knee function, although lateral joint laxity is allowed to a certain degree in TKA. METHODS: This study included 50 knees that underwent primary TKA. Knee laxity was measured with postoperative stress radiographs in flexion and extension, and patient satisfaction and knee function were evaluated by the 2011 Knee Society Knee Scoring System. RESULTS: In a comparison of medially tight and medially loose knees in flexion, the scores for satisfaction, symptoms, standard activity, and advanced activity were significantly better in medially tight than in medially loose knees (satisfaction: 29.8, 22.2; symptoms: 20.3, 15.9; standard activities: 24.2, 19.1; and advanced activities: 15.3, 8.7, in the tight and loose knees, respectively). Neither lateral joint laxity during knee flexion nor medial joint laxity during knee extension was associated with a poor postoperative clinical outcome, whereas lateral joint laxity and the standard activity score in extension had a moderate positive correlation. CONCLUSIONS: Knees with medial joint laxity during flexion resulted in an inferior postoperative outcome, and lateral joint laxity did not influence patient satisfaction or function. Care should be taken to maintain medial joint stability during the TKA procedure.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Satisfacción del Paciente/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
2.
J Orthop Sci ; 21(6): 727-731, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27589914

RESUMEN

BACKGROUND: For shoulder arthroscopy, few anatomical landmarks are available and inexperienced surgeons tend to be adrift due to the limited visual field of the scope. The purpose of this study was to demonstrate the useful landmarks around the glenoid for accurate orientation, and also the safe distance to avoid suprascapular nerve injury during surgical procedures around the glenoid. METHODS: In 15 human solution-fixed cadavers, a cross-section of the shoulder joint on the labrum surface was created. The positions of the principal anatomical structures surrounding the glenoid were marked on the labrum and measured using our clock face indication system. In 9 shoulders the distances from the labral surface to the spinoglenoid notch were recorded. As an indicator of the scapula size, the distances between the superior and inferior angles of the scapula were also measured. RESULTS: The average landmark positions in the right shoulder were as follows: center of the attachment of the long tendon 11:59, anterior edge of the supraspinatus 11:59, posterior edge of the base of the coracoid process 12:13, superior edge of the subscapularis 1:03, anterior edge of the base of the coracoid process 1:25, inferior edge of the subscapularis 5:27, inferior edge of the teres minor 6:21, border of the infraspinatus and teres minor 7:43, center of the scapula spine 10:06, border of the supra and infraspinatus 10:27. The average distance from the labral surface to the spinoglenoid notch was 23.17 mm, and that from the superior to inferior angle was 144.93 mm. The Pearson correlation coefficient for these distances was 0.007. CONCLUSIONS: The locations of anatomical landmarks surrounding the glenoid were reliably demonstrated using our clock face indication system. The expected distance from the labral surface to the suprascapular nerve was approximately 23 mm, irrespective of the size of the scapula.


Asunto(s)
Puntos Anatómicos de Referencia/cirugía , Artroscopía/métodos , Articulación del Hombro/anatomía & histología , Articulación del Hombro/cirugía , Cadáver , Femenino , Humanos , Masculino
3.
Knee Surg Sports Traumatol Arthrosc ; 22(2): 435-41, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23328991

RESUMEN

PURPOSE: The purpose of this study was to meticulously observe the structures around the origin of the long head of the biceps tendon (LHB) in order to propose a method of anatomical superior labrum anterior and posterior repair. METHODS: Twenty-eight shoulders of 16 cadavers with intact LHB origin were macroscopically investigated. Among them, 20 shoulders with an intact superior labrum were additionally observed, to determine whether the anterior edge of LHB on the labrum (point 'A') was anterior to the supraglenoid tubercle. Serial sections vertical to LHB were observed using ordinary light and polarized microscopy in three glenoids and scanning acoustic microscopy in one. RESULTS: The labrum had a meniscal appearance, and no LHB fibre was sent anterior to the anterior edge of the supraglenoid tubercle. 'A' was not located more posterior than the supraglenoid tubercle. All specimens had the so-called 'the sheet-like structure', in which the portion closer to the LHB origin tends to be stiffer. Fibres of the sheet-like structure ran vertically to LHB. CONCLUSION: Fibre orientation and the stiffness of the sheet-like structure suggest its support of LHB. As LHB fibres do not anteriorly cross over 'A', 'A' could be a landmark for the anterior border of LHB, independent from the sheet-like structure. Considering a previous report mentioning that the horizontal mattress suture maintains the meniscus-like structure which might be sufficient for proper motion of the normal superior labrum, the horizontal mattress suture not crossing over 'A' should be recommended from the viewpoint of functional anatomy.


Asunto(s)
Cavidad Glenoidea/anatomía & histología , Articulación del Hombro/anatomía & histología , Tendones/anatomía & histología , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Femenino , Cavidad Glenoidea/cirugía , Humanos , Masculino , Lesiones del Hombro , Articulación del Hombro/cirugía , Tendones/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA