Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chin Med Assoc ; 87(3): 334-339, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305707

RESUMEN

BACKGROUND: Laryngeal microsurgery (LMS) typically requires intubated general anesthesia (ITGA). Although nonintubated general anesthesia (NIGA) with high-flow nasal oxygen (HFNO) can be applied with LMS, a muscle relaxant is required, which can cause apnea and hypercapnia. This study evaluated the effectiveness of a superior laryngeal nerve block (SLNB) in improving safety during LMS. METHODS: This prospective cohort study enrolled a cumulative total of 61 adult patients received LMS under intravenous general anesthesia and allocated to three groups: ITGA group (n = 18), which patients performed intubation; neuromuscular blocking (NMB) group (n = 21), which patients administrated muscle relaxant without intubation and superior laryngeal nerve block (NB) group (n = 22), which patients performed SLNB without intubation or muscle relaxant. RESULTS: The average (SD) values of PaCO 2 after surgery in ITGA, NMB, and NB group were 50.8 (7.5), 97.5 (24.9), and 54.8 (8.8) mmHg, respectively. The mean postoperative pH values were 7.33 (0.04), 7.14 (0.07), and 7.33 (0.04), respectively. The results were all p < 0.001, and the average pH value of the NMB group was lower than that of the ITGA and NB groups. During the LMS, the mean heart rate (HR) (93.9 [18.1] bpm) and noninvasive blood pressure systolic (NBPs) (143.5 [28.2] mmHg) in the NMB group were higher than those in the ITGA group (HR = 77.4 [13.5] bpm and NBPs = 132.7 [20.8] mmHg) and NB group (HR = 82.3 [17.4] bpm and NBPs = 120.9 [25.0] mmHg). The results of p value by HR and NBPs are p < 0.001. The PaCO 2 and pH values are similar between ITGA group and NB group. CONCLUSION: Our approach of using HFNO with SLNB was successful for performing nonintubated LMS, enabling the patients to maintain spontaneous breathing and effectively eliminate CO 2 . This approach reduces the risks of hypercapnia and acidosis even when the duration of LMS exceeds 30 minutes.


Asunto(s)
Hipercapnia , Oxígeno , Adulto , Humanos , Microcirugia , Estudios Prospectivos , Nervios Laríngeos
2.
Colloids Surf B Biointerfaces ; 107: 152-9, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23500725

RESUMEN

Non-fouling surfaces that resist non-specific protein adsorption and cell adhesion are desired for many biomedical applications such as blood-contact devices and biosensors. Therefore, surface conjugation of anti-fouling molecules has been the focus of many studies. In this study, layer-by-layer polyelectrolyte deposition was applied to create an amine-rich platform for conjugation of zwitterionic polymers. A tri-layer polyelectrolyte (TLP) coating representing poly(ethylene imine) (PEI), poly(acrylic acid)-g-azide and PEI was deposited on various polymeric substrates via layer-by-layer deposition and then crosslinked via UV irradiation. Carboxyl-terminated poly(sulfobetaine methacrylate) p(SBMA) or poly(carboxybetaine methacrylate) p(CBMA) was then conjugated onto TLP coated substrates via a carbodiimide reaction. Our results demonstrate that the zwitterionic polymers could be easily conjugated over a wide pH range except under alkaline conditions, and almost completely block protein adsorption and the attachment of L929 cells and platelets. Therefore, this method has outstanding potential in biomedical applications that require low-fouling surfaces.


Asunto(s)
Betaína/farmacología , Fibrinógeno/metabolismo , Fibroblastos/citología , Metacrilatos/farmacología , Ácidos Polimetacrílicos/farmacología , Adsorción/efectos de los fármacos , Animales , Betaína/química , Adhesión Celular/efectos de los fármacos , Dimetilpolisiloxanos/química , Dimetilpolisiloxanos/farmacología , Electrólitos/química , Fibroblastos/efectos de los fármacos , Fibroblastos/metabolismo , Fibronectinas/metabolismo , Fluorescamina , Humanos , Concentración de Iones de Hidrógeno/efectos de los fármacos , Iones , Metacrilatos/química , Ratones , Adhesividad Plaquetaria/efectos de los fármacos , Ácidos Polimetacrílicos/química , Propiedades de Superficie/efectos de los fármacos , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA