Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Oral Maxillofac Surg ; 46(7): 845-850, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28385384

RESUMEN

Le Fort I osteotomy is the technique most applied worldwide in the treatment of dentoskeletal deformity involving the maxilla. Even though it is considered a very safe technique with good intra- and postoperative results, many complications have been described. This paper presents a case of carotid jugular fistula developed in a 22-year-old white male submitted to Le Fort I osteotomy for the treatment of anteroposterior maxillary deficiency, and discusses the possible aetiology and management of this serious complication.


Asunto(s)
Fístula Arteriovenosa/etiología , Traumatismos de las Arterias Carótidas/etiología , Venas Yugulares/lesiones , Osteotomía Le Fort/efectos adversos , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/cirugía , Angiografía Cerebral , Diagnóstico Diferencial , Humanos , Masculino , Tomografía Computarizada por Rayos X , Adulto Joven
2.
Br J Oral Maxillofac Surg ; 55(2): 136-140, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27776924

RESUMEN

The purpose of this study was to compare the mechanical resistance of three different plates used to treat fractures of the mandibular angle: a regular 4-hole plate, a longer 4-hole plate (both positioned using the Champy technique), and a 3-dimensional plate positioned over the oblique line. Three equal groups of replicas of human dentate mandibles made out of polyurethane resin were used (n=21 in each group). The force was applied perpendicular to the occlusal plane at a rate of 2mm/minute at three different points: the first molar on the sectioned side; the first molar on the contralateral side; and between the central incisors. This was followed by a resistance-to-load test. The two varying factors (type of plate and site-of-load application) were tested by analysis of variance, and probabilities of less than 0.05 were accepted as significant. There were no significant differences between the subgroups, or between the mean values of the different types of plates (p=0.925). The three types of plates showed similar mechanical behaviour, which showed that the 3-dimensional plates positioned over the oblique line can produce mechanical scores similar to those of conventional plates.


Asunto(s)
Placas Óseas , Fijación de Fractura/instrumentación , Fracturas Mandibulares/cirugía , Placas Óseas/clasificación , Humanos , Modelos Anatómicos
3.
Int J Oral Maxillofac Surg ; 43(5): 559-63, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24216298

RESUMEN

The aim of this in vitro study was to evaluate the mechanical resistance of a 2.0-mm titanium system applied to the mandibular angle, either with or without continuity of the inferior border of the mandible. Polyurethane mandibles were used as substrates and divided into two groups: unfavourable and favourable to treatment. A single cut was made through the retromolar region, simulating an angle fracture either unfavourable or favourable to treatment. In addition, a small fragment of the inferior border of the mandible was removed in some of the mandibles, creating a discontinuity. The fragments were stabilized in accordance with the technique of Champy et al. The substrates were adapted to a universal mechanical testing machine and submitted to a constant load applied at three different points; load values were obtained at three different moments of displacement: 1mm, 2mm, and fixation failure. The value of the tip dislocation at final displacement was obtained. When the load was applied at the first molars, regardless of the side, no statistically significant difference was observed between the groups. When the load was applied at the central incisors, a statistically significant difference was observed at fixation failure in the unfavourable to treatment group, with better results in the subgroup with continuity of the inferior border of the mandible compared to the subgroup without continuity. Discontinuity of the inferior border of the mandible did not decrease the mechanical resistance of the fixation.


Asunto(s)
Fijación Interna de Fracturas/instrumentación , Fijadores Internos , Fracturas Mandibulares/cirugía , Fenómenos Biomecánicos , Humanos , Técnicas In Vitro , Modelos Anatómicos , Poliuretanos , Diseño de Prótesis , Estrés Mecánico , Titanio
4.
Int J Oral Maxillofac Surg ; 41(11): 1361-8, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22633468

RESUMEN

The objective of this study was to compare the bone repair along a mandibular body osteotomy stabilized with 2.0 mm absorbable and metallic systems. 12 male, adult mongrel dogs were divided into two groups (metallic and absorbable) and subjected to unilateral osteotomy between the mandibular third and fourth premolars, which was stabilized by applying two 4-hole plates. At 2 and 18 weeks, three dogs from each group were killed and the osteotomy sites were removed and divided equally into three parts: the upper part was labelled the tension third (TT), the lower part the compression third (CT), and the part between the TT and CT the intermediary third (IT). Regardless of the treatment system, union between the fragments was observed at 18 weeks and the CT showed more advanced stages of bone repair than the TT. Histometric analysis did not reveal any significant differences among the 3 parts or systems in the distance between bone fragments at 2 weeks. Although at 18 weeks the proportions of newly formed bone did not differ among TT, IT and CT, significantly enhanced bone formation was observed in all sections for the metallic group. The patterns of repair were distinct between treatments.


Asunto(s)
Materiales Biocompatibles , Fijadores Internos , Mandíbula/cirugía , Metales , Osteotomía , Animales , Perros
5.
Int J Oral Maxillofac Surg ; 41(3): 380-3, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22004947

RESUMEN

This manuscript reports an uncommon case of inferior third molar facial abscess with purulent secretion drainage through the left external acoustic meatus. The patient's left external acoustic meatus was filled with a purulent secretion observed on a CT scan. He underwent surgery to drain the facial abscess. Despite facial abscesses being routine occurrences, the literature does not contain many case reports of odontogenic facial abscesses with drainage via the external acoustic meatus. These situations occur in two possible ways: multiple fissures in the anterior wall of the cartilaginous portion of the external acoustic meatus; and congenital defects that are occasionally present in the anterior-superior aspect of the external acoustic meatus, known as the foramen of Huschke, which allow communication between the external acoustic meatus and mandibular fossa. These defects may also predispose the patient to the spread of the infection or tumour from the external auditory canal to the infratemporal fossa and vice versa. No otological sequelae were observed in this case. The authors conclude that the hypothesis of bone malformation cannot be excluded, and affirm that any facial abscess requires appropriate and immediate treatment for adequate resolution, by removing the causal factor and providing systemic support.


Asunto(s)
Absceso/diagnóstico , Conducto Auditivo Externo/anomalías , Enfermedades Mandibulares/diagnóstico , Infección de la Herida Quirúrgica/diagnóstico , Adulto , Combinación Amoxicilina-Clavulanato de Potasio/uso terapéutico , Antibacterianos/uso terapéutico , Drenaje , Dolor de Oído/diagnóstico , Estudios de Seguimiento , Humanos , Masculino , Tercer Molar/cirugía , Supuración , Hueso Temporal/anomalías , Irrigación Terapéutica , Extracción Dental
6.
Int J Oral Maxillofac Surg ; 40(3): 316-21, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21067895

RESUMEN

The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1mm of displacement, no statistically significant difference was found. At 2mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles/química , Placas Óseas , Tornillos Óseos , Fijación de Fractura/instrumentación , Ácido Láctico/química , Fracturas Mandibulares/cirugía , Polímeros/química , Titanio/química , Fenómenos Biomecánicos , Arco Dental/patología , Falla de Equipo , Humanos , Incisivo/patología , Fijadores Internos , Mandíbula/patología , Ensayo de Materiales , Modelos Anatómicos , Diente Molar/patología , Poliésteres , Poliuretanos/química , Estrés Mecánico
7.
Int J Oral Maxillofac Surg ; 39(1): 10-5, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19914802

RESUMEN

This retrospective study evaluated the epidemiology, treatment and complications of mandibular fracture associated, or not associated, with other facial fractures, when the influence of the surgeon's skill and preference for any rigid internal fixation (RIF) system devices was minimized. The files of 700 patients with facial trauma were available, and 126 files were chosen for review. Data were collected regarding gender, age, race, date of trauma, date of surgery, addictions, etiology, signs and symptoms, fracture area, complications, treatment performed, date of hospital discharge, and medication. 126 patients suffered mandibular fractures associated, or not, with other maxillofacial fractures, and a total of 201 mandibular fractures were found. The incidence of mandibular fractures was more prevalent in males, in Caucasians and during the third decade of life. The most common site was the condyle, followed by the mandibular body. The therapy applied was effective in handling this type of fracture and the success rates were comparable with other published data.


Asunto(s)
Fracturas Mandibulares/epidemiología , Accidentes de Tránsito/estadística & datos numéricos , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Consumo de Bebidas Alcohólicas/epidemiología , Brasil/epidemiología , Niño , Preescolar , Mentón/lesiones , Mentón/inervación , Huesos Faciales/lesiones , Femenino , Estudios de Seguimiento , Fijación de Fractura/estadística & datos numéricos , Humanos , Incidencia , Estudios Longitudinales , Masculino , Cóndilo Mandibular/lesiones , Fracturas Mandibulares/clasificación , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Trastornos de la Sensación/epidemiología , Factores Sexuales , Fracturas Craneales/epidemiología , Fumar/epidemiología , Infección de la Herida Quirúrgica/epidemiología , Adulto Joven
10.
Revista da Associacao Paulista de Cirurgioes Dentistas;60(4): 315-319,
en Portugués | URUGUAIODONTO | ID: odn-19923
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA