Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Bioeng Biotechnol ; 11: 1127855, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36926690

RESUMEN

Background: Image-based computational hemodynamic modeling and simulations are important for personalized diagnosis and treatment of cardiovascular diseases. However, the required patient-specific boundary conditions are often not available and need to be estimated. Methods: We propose a pipeline for estimating the parameters of the popular three-element Windkessel (WK3) models (a proximal resistor in series with a parallel combination of a distal resistor and a capacitor) of the aortic arch arteries in patients receiving thoracic endovascular aortic repair of aneurysms. Pre-operative and post-operative 1-week duplex ultrasound scans were performed to obtain blood flow rates, and intra-operative pressure measurements were also performed invasively using a pressure transducer pre- and post-stent graft deployment in arch arteries. The patient-specific WK3 model parameters were derived from the flow rate and pressure waveforms using an optimization algorithm reducing the error between simulated and measured pressure data. The resistors were normalized by total resistance, and the capacitor was normalized by total resistance and heart rate. The normalized WK3 parameters can be combined with readily available vessel diameter, brachial blood pressure, and heart rate data to estimate WK3 parameters of other patients non-invasively. Results: Ten patients were studied. The medians (interquartile range) of the normalized proximal resistor, distal resistor, and capacitor parameters are 0.10 (0.07-0.15), 0.90 (0.84-0.93), and 0.46 (0.33-0.58), respectively, for common carotid artery; 0.03 (0.02-0.04), 0.97 (0.96-0.98), and 1.91 (1.63-2.26) for subclavian artery; 0.18 (0.08-0.41), 0.82 (0.59-0.92), and 0.47 (0.32-0.85) for vertebral artery. The estimated pressure showed fairly high tolerance to patient-specific inlet flow rate waveforms using the WK3 parameters estimated from the medians of the normalized parameters. Conclusion: When patient-specific outflow boundary conditions are not available, our proposed pipeline can be used to estimate the WK3 parameters of arch arteries.

2.
Clin Nucl Med ; 46(12): e567-e569, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33883489

RESUMEN

ABSTRACT: A 15-year-old girl with a history of complex congenital heart disease and prior pulmonary valve replacement presented with suspected endocarditis. PET/CT imaging with 18F-FDG was performed to evaluate the potential presence of intracardiac vegetations after previously inconclusive findings from CT angiography, transthoracic echocardiography, and transesophageal echocardiography. PET/CT detected heterogeneous, asymmetric, increased 18F-FDG uptake in the region of the pulmonary valve prosthesis, typical for infection, and confirmed diagnosis of bacterial infective endocarditis. This report highlights the utility of 18F-FDG PET/CT imaging to complement the Duke criteria for determining the diagnosis and therapeutic management of pediatric patients with infective endocarditis.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Adolescente , Niño , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos
4.
Eur J Vasc Endovasc Surg ; 59(1): 7-15, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31761570

RESUMEN

OBJECTIVE: Branched stent grafts represent a viable option for left subclavian artery (LSA) revascularisation in patients treated by thoracic endovascular aortic repair (TEVAR) for Zone 2 lesions. This study investigated the haemodynamic performance of different LSA branched stent graft configurations as potential determinants of thrombotic and stroke risks. METHODS: A three dimensional aortic arch geometry extracted from post-operative computed tomography images of a TEVAR patient using a single LSA branched aortic endograft was modified in silico to obtain ten potential LSA branched stent graft configurations: five down facing (0-5 - 10 mm aortic protrusion with 10-12 mm internal diameter), four curved (30-60° with antegrade/retrograde orientation), and one LSA orifice misalignment. The 0 mm down facing stent graft was considered base configuration. Computational fluid dynamic analyses were performed to identify differences in pressure, energy, and wall shear stress (WSS) based parameters. RESULTS: Total pressure drop and energy loss variations among configurations were not greater than 5 mmHg (6% of mean arterial pressure) and 5.7 mW (0.7% of cardiac power), respectively. Protrusions up to 5 mm created clinically insignificant flow disturbances. However, stent graft protrusions further into the aortic lumen created more complex haemodynamics, characterised by larger energy loss and more prominent flow recirculation. Protrusion greater than 5 mm into the lumen was associated with larger areas of elevated maximum WSS (>20 Pa) along the outer surface of the branched stent graft. CONCLUSION: Arterial haemodynamic characteristics are affected by LSA branched stent graft configurations, with pressure drops and energy losses likely to be clinically insignificant. The length of the stent graft protrusion into the aortic lumen generated the largest haemodynamic variations in the aortic system. Protrusions up to 5 mm have smaller risk of potential thrombus generation. Conversely, larger protrusions into the aortic lumen showed more disturbed haemodynamics, suggesting a greater risk of potential thrombus formation, which may be clinically important over time.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Hemodinámica/fisiología , Stents/efectos adversos , Arteria Subclavia/fisiopatología , Anciano , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Simulación por Computador , Diseño Asistido por Computadora , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Modelos Anatómicos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis/efectos adversos , Diseño de Prótesis/métodos , Arteria Subclavia/cirugía , Trombosis/etiología , Trombosis/fisiopatología , Trombosis/prevención & control , Tomografía Computarizada por Rayos X
5.
J Vasc Surg Cases Innov Tech ; 5(2): 187-194, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31193609

RESUMEN

We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an increased flow rate led to complex hemodynamics with high wall shear stress, probably resulting in high-shear thrombogenesis and chimney stent graft occlusion 2.6 years after the primary repair. Early postoperative duplex ultrasound imaging might help identify at-risk conditions.

6.
J Endovasc Ther ; 24(6): 880-888, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28914135

RESUMEN

PURPOSE: To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). METHODS: A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. RESULTS: Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. CONCLUSION: Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Oclusión de Injerto Vascular/etiología , Hemodinámica , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Simulación por Computador , Procedimientos Endovasculares/efectos adversos , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
7.
J Vasc Surg ; 66(1): 9-20.e3, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28216358

RESUMEN

BACKGROUND: Aortic arch disease is a challenging clinical problem, especially in high-risk patients, in whom open repair can have morbidity and mortality rates of 30% to 40% and 2% to 20%, respectively. Aortic arch chimney (AAC) stents used during thoracic endovascular aortic repair (TEVAR) are a less invasive treatment strategy than open repair, but the current literature is inconclusive about the role of this technology. The focus of this analysis is on our experience with TEVAR and AAC stents. METHODS: All TEVAR procedures performed from 2002 to 2015 were reviewed to identify those with AAC stents. Primary end points were technical success and 30-day and 1-year mortality. Secondary end points included complications, reintervention, and endoleak. Technical success was defined as a patient's surviving the index operation with deployment of the AAC stent at the intended treatment zone with no evidence of type I or type III endoleak on initial postoperative imaging. The Kaplan-Meier method was used to estimate survival. RESULTS: Twenty-seven patients (age, 69 ± 12 years; male, 70%) were identified, and all were described as being at prohibitive risk for open repair by the treating team. Relevant comorbidity rates were as follows: coronary artery disease/myocardial infarction, 59%; oxygen-dependent emphysema, 30%; preoperative creatinine concentration >1.8 mg/dL, 19%; and congestive heart failure, 15%. Presentations included elective (67%; n = 18), symptomatic (26%; n = 7), and ruptured (7%; n = 2). Eleven patients (41%) had prior endovascular or open arch/descending thoracic repair. Indications were degenerative aneurysm (49%), chronic residual type A dissection with aneurysm (15%), type Ia endoleak after TEVAR (11%), postsurgical pseudoaneurysm (11%), penetrating ulcer (7%), and acute type B dissection (7%). Thirty-two brachiocephalic vessels were treated: innominate (n = 7), left common carotid artery (LCCA; n = 24), and left subclavian artery (n = 1). Five patients (19%) had simultaneous innominate-LCCA chimneys. Brachiocephalic chimney stents were planned in 75% (n = 24), with the remainder placed for either LCCA or innominate artery encroachment (n = 8). Overall technical success was 89% (one intraoperative death, two persistent type Ia endoleaks in follow-up). The 30-day mortality was 4% (n = 1; intraoperative death of a patient with a ruptured arch aneurysm), and median length of stay was 6 (interquartile range, 4-9) days. Seven (26%) patients experienced a major complication (stroke, three [all with unplanned brachiocephalic chimney]; respiratory failure, three; and death, one). Nine (33%) patients underwent aorta-related reintervention, and no chimney occlusion events occurred during follow-up (median follow-up, 9 [interquartile range, 1-23] months). The 1-year and 3-year survival is estimated to be 88% ± 6% and 69% ± 9%, respectively. CONCLUSIONS: TEVAR with AAC can be performed with high technical success and acceptable morbidity and mortality in high-risk patients. Unplanned AAC placement during TEVAR results in an elevated stroke risk, which may be related to the branch vessel coverage necessitating AAC placement. Acceptable midterm survival can be anticipated, but aorta-related reintervention is not uncommon, and diligent follow-up is needed.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Úlcera/cirugía , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Comorbilidad , Angiografía por Tomografía Computarizada , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Florida , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Úlcera/diagnóstico por imagen , Úlcera/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA