Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Biomed Mater Res B Appl Biomater ; 110(12): 2744-2750, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35857711

RESUMEN

The aim of this study was to evaluate the in vivo performance of two different deproteinized bovine bone (DBB) grafting materials: DBBB (Bio-Oss®) and DBBL (Laddec®), for the regeneration of critically sized (8 mm) defects in rabbit's calvaria. Three round-shaped defects were surgically created in the calvaria of 13 New Zealand White rabbits proximal to the coronal suture in the parietal bone. Two of the defects were filled with one of the grafting materials while a third was left empty to serve as a negative control. Bone regeneration properties were evaluated at 4- and 8-weeks after implantation by means of histological and histomorphometrical analyses. Statistical analyses were performed through a mixed model analysis with fixed factors of time and material. Histological evaluation of the control group evidenced a lack of bridging bone formation across the defect sites at both evaluation time points. For the experimental groups, new bone formation was observed around the defect periphery and to progress radially inwards to the center of the defect site, regardless of the grafting material. Histomorphometric analyses at 4 weeks demonstrated higher amount of bone formation through the defect for DBBB group. However, at 8 weeks, DBBL and DBBB demonstrated osteoconductivity and low resorption rates with evidence of statistically similar bone regeneration through the complete boney defect. Finally, DBBB presented lower soft tissue migration within the defect when compared to DBBL at both evaluation time points. DBBB and DBBL presented similar bone regeneration performance and slow resorption rates. Although both materials promoted bone regeneration through the complete defect, DBBB presented lower soft tissue migration within the defects at 4- and 8-weeks.


Asunto(s)
Sustitutos de Huesos , Animales , Regeneración Ósea , Sustitutos de Huesos/farmacología , Trasplante Óseo , Bovinos , Minerales , Conejos , Cráneo/cirugía
2.
J Appl Oral Sci ; 30: e20210475, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35476114

RESUMEN

Glass ceramics' fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness. OBJECTIVES: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments. METHODOLOGY: Three composite resin replicas of the maxillary first premolar and crown-prepared abutment first molar were made to obtain three-unit FDPs. The FDPs were veneered with glass ceramic containing fluorapatite crystals and resin cemented on the replicas, embedded in epoxy resin, sectioned, and polished. Each specimen was subjected to nanoindentation in the following regions of interest: 1) Mesial premolar abutment (MPMa); 2) Distal premolar abutment (DPMa); 3) Buccal premolar abutment (BPMa); 4) Lingual premolar abutment (LPMa); 5) Mesial premolar pontic (MPMp); 6) Distal premolar pontic (DPMp); 7) Buccal premolar pontic (BPMp); 8) Lingual premolar pontic (LPMp); 9) Mesial molar abutment (MMa); 10) Distal molar abutment (DMa); 11) Buccal molar abutment (BMa); and 12) Lingual molar abutment (LMa). Data were assessed using Linear Mixed Model and Least Significant Difference (95%) tests. RESULTS: Pontics had significantly higher hardness values than premolar (p=0.001) and molar (p=0.007) abutments, suggesting lower residual stress levels. Marginal ridges yielded higher hardness values for connectors (DPMa, MMa, MPMp and DPMp) than for outer proximal surfaces of abutments (MPMa and DMa). The mesial marginal ridge of the premolar abutment (MPMa) had the lowest hardness values, suggesting higher residual stress concentration. CONCLUSIONS: Residual stress in three-unit FDPs was lower in pontics than in abutments. The outer proximal surfaces of the abutments had the highest residual stress concentration.


Asunto(s)
Dentadura Parcial Fija , Circonio , Diente Premolar , Coronas , Circonio/química
3.
J. appl. oral sci ; J. appl. oral sci;30: e20210475, 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1375709

RESUMEN

Abstract Glass ceramics' fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness. Objectives: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments. Methodology: Three composite resin replicas of the maxillary first premolar and crown-prepared abutment first molar were made to obtain three-unit FDPs. The FDPs were veneered with glass ceramic containing fluorapatite crystals and resin cemented on the replicas, embedded in epoxy resin, sectioned, and polished. Each specimen was subjected to nanoindentation in the following regions of interest: 1) Mesial premolar abutment (MPMa); 2) Distal premolar abutment (DPMa); 3) Buccal premolar abutment (BPMa); 4) Lingual premolar abutment (LPMa); 5) Mesial premolar pontic (MPMp); 6) Distal premolar pontic (DPMp); 7) Buccal premolar pontic (BPMp); 8) Lingual premolar pontic (LPMp); 9) Mesial molar abutment (MMa); 10) Distal molar abutment (DMa); 11) Buccal molar abutment (BMa); and 12) Lingual molar abutment (LMa). Data were assessed using Linear Mixed Model and Least Significant Difference (95%) tests. Results: Pontics had significantly higher hardness values than premolar (p=0.001) and molar (p=0.007) abutments, suggesting lower residual stress levels. Marginal ridges yielded higher hardness values for connectors (DPMa, MMa, MPMp and DPMp) than for outer proximal surfaces of abutments (MPMa and DMa). The mesial marginal ridge of the premolar abutment (MPMa) had the lowest hardness values, suggesting higher residual stress concentration. Conclusions: Residual stress in three-unit FDPs was lower in pontics than in abutments. The outer proximal surfaces of the abutments had the highest residual stress concentration.

4.
J Craniofac Surg ; 32(3): 1177-1181, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33003153

RESUMEN

BACKGROUND/PURPOSE: The utilization of three-dimensionally (3D)-printed bioceramic scaffolds composed of beta-tricalcium phosphate in conjunction with dipyridamole have shown to be effective in the osteogenesis of critical bone defects in both skeletally immature and mature animals. Furthermore, previous studies have proven the dura and pericranium's osteogenic capacity in the presence of 3D-printed scaffolds; however, the effect galea aponeurotica on osteogenesis in the presence of 3D scaffolds remains unclear. METHOD/DESCRIPTION: Critical-sized (11 mm) bilateral calvarial defects were created in 35-day old rabbits (n = 7). Two different 3D scaffolds were created, with one side of the calvaria being treated with a solid nonporous cap and the other with a fully porous cap. The solid cap feature was designed with the intention of preventing communication of the galea and the ossification site, while the porous cap permitted such communication. The rabbits were euthanized 8 weeks postoperatively. Calvaria were analyzed using microcomputed tomography, 3D reconstruction, and nondecalcified histologic sectioning in order assess differences in bone growth between the two types of scaffolding. RESULTS: Scaffolds with the solid (nonporous) cap yielded greater percent bone volume (P = 0.012) as well as a greater percent potential bone (P = 0.001) compared with the scaffolds with a porous cap. The scaffolds with porous caps also exhibited a greater percent volume of soft tissue (P < 0.001) presence. There were no statistically significant differences detected in scaffold volume. CONCLUSION: A physical barrier preventing the interaction of the galea aponeurotica with the scaffold leads to significantly increased calvarial bone regeneration in comparison with the scaffolds allowing for this interaction. The galea's interaction also leads to more soft tissue growth hindering the in growth of bone in the porous-cap scaffolds.


Asunto(s)
Impresión Tridimensional , Andamios del Tejido , Animales , Regeneración Ósea , Cerámica , Osteogénesis , Conejos , Microtomografía por Rayos X
5.
Periodontol 2000 ; 81(1): 139-151, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31407440

RESUMEN

This paper is aimed to present a biomaterials perspective in implant therapy that fosters improved bone response and long-term biomechanical competence from surgical instrumentation to final prosthetic rehabilitation. Strategies to develop implant surface texturing will be presented and their role as an ad hoc treatment discussed in light of the interplay between surgical instrumentation and implant macrogeometric configuration. Evidence from human retrieved implants in service for several years and from in vivo studies will be used to show how the interplay between surgical instrumentation and implant macrogeometry design affect osseointegration healing pathways, and bone morphologic and long-term mechanical properties. Also, the planning of implant-supported prosthetic rehabilitations targeted at long-term performance will be appraised from a standpoint where personal preferences (eg, cementing or screwing a prosthesis) can very often fail to deliver the best patient care. Lastly, the acknowledgement that every rehabilitation will have its strength degraded over time once in function will be highlighted, since the potential occurrence of even minor failures is rarely presented to patients prior to treatment.


Asunto(s)
Implantes Dentales , Materiales Biocompatibles , Implantación Dental Endoósea , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Humanos , Oseointegración
6.
J Long Term Eff Med Implants ; 29(4): 295-302, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32749134

RESUMEN

This study evaluates the influence of two surface physicochemical modifications on osseointegration parameters of a healing chamber implant design. We examine dental implants with internal and external trapezoidal threads that have the following surface modifications: dual acid etching (DAE) and nano-hydroxyapatite (HA) coating over DAE surface (Nano). We installed implants in the right ilium of sheep and conducted histologic/metric analyses after 3 and 12 wk in vivo. We quantified the percentage of bone-to-implant contact (%BIC) and bone area fraction occupancy (%BAFO) within implant threads. Histologic micrographs indicate early bone formation within the healing chambers of implants with Nano surface relative to DAE surface. Histomorphometric analysis demonstrates there to be no significant differences in %BIC between 3 and 12 wk (p = 0.298). Compared to DAE, Nano shows more bone formation in contact with implant, regardless of time (p < 0.025). We observe > %BAFO at 12 wk relative to 3 wk, which differs significantly for Nano (p < 0.038). Implant surface treatment affects the amounts of bone formation within healing chambers, with Nano significantly outperforming DAE at 12 wk (p < 0.025). Nano presents a synergistic effect with implant design, improving osseointegration parameters.

7.
J Oral Maxillofac Surg ; 76(1): 71-79, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28893541

RESUMEN

PURPOSE: This work evaluated the nanomechanical properties of bone surrounding submerged and immediately loaded implants after 3 years in vivo. It was hypothesized that the nanomechanical properties of bone would markedly increase in immediately and functionally loaded implants compared with submerged implants. MATERIALS AND METHODS: The second, third, and fourth right premolars and the first molar of 10 adult Doberman dogs were extracted. After 6 months, 4 implants were placed in 1 side of the mandible. The mesial implant received a cover screw and remained unloaded. The remaining 3 implants received fixed dental prostheses within 48 hours after surgery that remained in occlusal function for 3 years. After sacrifice, the bone was prepared for histologic and nanoindentation analysis. Nanoindentation was carried out under wet conditions on bone areas within the plateaus. Indentations (n = 30 per histologic section) were performed with a maximum load of 300 µN (loading rate, 60 µN per second) followed by a holding and unloading time of 10 and 2 seconds, respectively. Elastic modulus (E) and hardness (H) were computed in giga-pascals. The amount of bone-to-implant contact (BIC) also was evaluated. RESULTS: The E and H values for cortical bone regions were higher than those for trabecular bone regardless of load condition, but this difference was not statistically significant (P > .05). The E and H values were higher for loaded implants than for submerged implants (P < .05) for cortical and trabecular bone. For the same load condition, the E and H values for cortical and trabecular bone were not statistically different (P > .05). The loaded and submerged implants presented BIC values (mean ± standard deviation) of 57.4 ± 12.1% and 62 ± 7.5%, respectively (P > .05). CONCLUSION: The E and H values of bone surrounding dental implants, measured by nanoindentation, were higher for immediately loaded than for submerged implants.


Asunto(s)
Proceso Alveolar/ultraestructura , Implantación Dental Endoósea/métodos , Implantes Dentales , Mandíbula/cirugía , Animales , Diente Premolar , Diseño de Prótesis Dental , Análisis del Estrés Dental , Perros , Implantes Experimentales , Diente Molar
8.
J Biomater Appl ; 30(7): 900-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26508287

RESUMEN

Surface topography modifications have become a key strategy for hastening the host-to-implant response to implantable materials. The present study evaluated the effect of three different carefully controlled surface texture patterns achieved through microrobotized blasting (controlled to high, medium and low roughness) relative to a larger scale blasting procedure (control) in early osseointegration in a canine model. Four commercially pure grade 2 titanium alloy implants (one of each surface) were bilaterally placed in the radii of six beagle dogs and allowed end points of 1 and 6 weeks in vivo. Following sacrifice, implants in bone were non-decalcified processed for bone morphologic and histometric (bone-to-implant contact; bone area fraction occupancy) evaluation. Surface topography was characterized by scanning electron microscopy and optical interferometry. Results showed initial osteogenic tissue interaction at one week and new bone in intimate contact with all implant surfaces at 6 weeks. At 1 and 6 weeks in vivo, higher bone-to-implant and bone area fraction occupancy were observed for the high texture pattern microrobotized blasted surface relative to others.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Implantes Dentales , Oseointegración/fisiología , Aleaciones , Animales , Sustitutos de Huesos , Huesos , Perros , Interferometría , Masculino , Microscopía Electrónica de Rastreo , Miniaturización , Óptica y Fotónica , Diseño de Prótesis , Robótica , Propiedades de Superficie , Titanio/química
9.
J Biomed Mater Res B Appl Biomater ; 103(6): 1328-32, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25367155

RESUMEN

Although preclinical and sparse human histology retrieval studies have shown that the interface between implant and bone is constantly remodeling, no human retrieval database has been developed to determine the effect of functional loading time and other clinical/implant design variables on osseointegration. The present study tested the hypothesis that bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) increase over functional loading time around dental implants. Due to prosthetic retreatment reasons, 93 human implant retrievals from the same manufacturer (Bicon LLC, Boston, MA, USA) were obtained over a period of approximately 15 years. The retrieved implants were under functional loading from 120 days to ∼18 years and were histomorphologic/metrically evaluated. BIC/BAFO were assessed as a function of multiple independent variables: implant surface type, diameter, length, jaw (maxilla/mandible), region (anterior/posterior), and time of functional loading. The results showed that both BIC and BAFO increased over time independently of implant design/clinical variables, supporting the postulated hypothesis.


Asunto(s)
Interfase Hueso-Implante/patología , Implantación Dental Endoósea , Implantes Dentales , Femenino , Humanos , Masculino , Factores de Tiempo , Soporte de Peso
10.
J Craniofac Surg ; 25(1): 70-6, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24275773

RESUMEN

Particulate bone augmentation is an established clinical alternative to regenerate bone. However, in regions of poor bone quality or previously infected sites, the clinical outcomes are more inconsistent. For that purpose, peptides have been added to particulate materials in an attempt to render them with antibacterial properties or to improve their osseoconductivity. For instance, competence-stimulating peptide (CSP) has been studied to decrease the division rate of Streptococcus mutans. Also, the addition of a specific short amino acid sequence peptide derived from type I collagen (P-15) to the bone substitutes has been introduced in an attempt to increase its osseoconductivity. The present study hypothesized that xenogeneic graft materials with and without CSP would present improved host-to-biomaterial response when used in combination with P-15. Particulate graft materials with and without P-15, OsteoGraf with CSP and OsteoGraf, were implanted in an 8-mm rabbit calvarial defect for 4 weeks, and thereafter, histological and histomorphometrical evaluation was performed. The results showed that both OsteoGraf and CSP groups with the addition of P-15 induced bone growth towards the center of the defect. Furthermore, the addition of CSP to Osteograf showed a tendency to increase its osteoconductivity when combined with P-15. The results of the current study suggested that P-15 had some impact on osteogenesis; however, the effect differed between different bone substitute materials. Further investigation is necessary to clarify its effectiveness when used in combination with bone substitutes.


Asunto(s)
Sustitutos de Huesos/uso terapéutico , Colágeno/uso terapéutico , Xenoinjertos/trasplante , Fragmentos de Péptidos/uso terapéutico , Animales , Proteínas Bacterianas/uso terapéutico , Enfermedades Óseas/patología , Enfermedades Óseas/cirugía , Regeneración Ósea/efectos de los fármacos , Remodelación Ósea/efectos de los fármacos , Trasplante Óseo/métodos , Bovinos , Competencia de la Transformación por ADN/fisiología , Osteoblastos/efectos de los fármacos , Osteoblastos/patología , Osteogénesis/efectos de los fármacos , Hueso Parietal/efectos de los fármacos , Hueso Parietal/patología , Hueso Parietal/cirugía , Conejos
11.
Clin Implant Dent Relat Res ; 16(6): 913-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23527994

RESUMEN

BACKGROUND: It has been reported that titanium-zirconium alloy with 13-17% zirconium (TiZr1317) implants show higher biomechanical stability and bone area percentage relative to commercially pure titanium (cpTi) grade 4 fixtures. PURPOSE: This study aimed to determine whether the higher stability for TiZr1317 implants is associated with higher mechanical properties of remodeling bone in the areas around the implants. MATERIALS AND METHODS: This study utilized 36 implants (n = 18: TiZr1317, n = 18: cpTi), which were placed in the healed ridges of the mandibular premolar and first molar of 12 mini pigs (n = 3 implants/animal). After 4 weeks in vivo, the samples were retrieved, and resin-embedded histologic sections of approximately 100 µm in thickness were prepared. In order to determine the nanomechanical properties, nanoindentation (n = 30 tests/specimen) was performed on the bone tissue of the sections under wet conditions with maximum load of 300 µN (loading rate: 60 µN/s). RESULTS: The mean (± standard deviation) elastic modulus (E) and hardness (H) for the TiZr1317 group were 2.73 ± 0.50 GPa and 0.116 ± 0.017 GPa, respectively. For the cpTi group, values were 2.68 ± 0.51 GPa and 0.110 ± 0.017 GPa for E and H, respectively. Although slightly higher mechanical properties values were observed for the TiZr1317 implants relative to the cpTi for both elastic modulus and hardness, these differences were not significant (E = p > 0.75; H = p > 0.59). CONCLUSIONS: The titanium-zirconium alloy used in this study presented similar degrees of nanomechanical properties to that of the cpTi implants.


Asunto(s)
Aleaciones/química , Remodelación Ósea/fisiología , Implantes Dentales , Materiales Dentales/química , Mandíbula/fisiología , Titanio/química , Animales , Fenómenos Biomecánicos , Interfase Hueso-Implante/anatomía & histología , Interfase Hueso-Implante/fisiología , Módulo de Elasticidad , Femenino , Dureza , Mandíbula/anatomía & histología , Ensayo de Materiales , Nanotecnología , Oseointegración/fisiología , Estrés Mecánico , Porcinos , Porcinos Enanos , Cicatrización de Heridas/fisiología
12.
ImplantNews ; 11(3): 296-301, 2014. ilus, tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-730877

RESUMEN

Objetivo: apresentar os resultados histológicos e histomorfométricos do uso de três substitutos ósseos disponíveis comercialmente, com relação à sua capacidade de regeneração óssea. Material e métodos: foram utilizados três biomateriais para preenchimento de defeitos críticos na calvária de coelhos, e mantidos por quatro e oito semanas in vivo. Resultados: do ponto de vista morfológico, um padrão de cicatrização semelhante foi observado para os três diferentes materiais, em que a formação do osso foi observada a partir das margens para o centro do defeito, nos tempos decorridos in vivo. De um ponto de vista quantitativo, o material NanoSynt apresentou maiores níveis médio de formação óssea, quantidade de biomaterial e de manutenção de espaço do defeito in vivo, quando comparado aos outros dois biomateriais. Conclusão: todos os substitutos ósseos utilizados apresentaram características de biocompatibilidade, não interferindo negativamente no processo de reparo. Entretanto, o biomaterial sintético NanoSynt apresentou maior nível de formação óssea e manutenção do espaço do defeito, quando comparado aos materiais Boneceramic e Bio-Oss durante os dois períodos in vivo do presente estudo (quatro e oito semanas).


Objective: to present the histological and histomorphometric results on the use of three commercially available bone substitutes with respect to its capacity of bone regeneration. Material and methods: three biomaterials were used to fill critical defects in the calvaria of rabbits kept 4 and 8 weeks in vivo. Results: from the morphological point of view, a similar pattern of healing was observed for three different materials, in which bone formation was observed from the margins to the center of the deffect, according to evaluated periods. From a quantitative point of view, the NanoSynt material exhibited higher mean levels of bone formation, amount of biomaterial, and space maintenance defect in vivo when compared to the other two biomaterials. Conclusion: all bone substitutes used showed biocompatibility and does not interfere negatively in the repair process. However, the synthetic biomaterial NanoSynt showed higher levels of bone formation and maintenance of the area of the defect when compared to materials BoneCeramic and Bio-Oss during the two periods in vivo in the present study (4 and 8 weeks).


Asunto(s)
Animales , Conejos , Materiales Biocompatibles , Regeneración Ósea
13.
Int J Dent ; 2013: 296391, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24285956

RESUMEN

Lateral or vertical bone augmentation has always been a challenge, since the site is exposed to constant pressure from the soft tissue, and blood supply only exists from the donor site. Although, for such clinical cases, onlay grafting with autogenous bone is commonly selected, the invasiveness of the secondary surgical site and the relatively fast resorption rate have been reported as a drawback, which motivated the investigation of alternative approaches. This study evaluated the bone-forming capability of a novel nanoHA alloplast infused with collagen graft material made from biodegradable polylactic acid/polyglycolic acid versus a control graft material with the same synthesized alloplast without the nanoHA component and collagen infiltration. The status of newly formed bone and the resorption of the graft material were evaluated at 6 weeks in vivo histologically and three dimensionally by means of 3D microcomputed tomography. The histologic observation showed that newly formed bone ingrowth and internal resorption of the block were observed for the experimental blocks, whereas for the control blocks less bone ingrowth occurred along with lower resorption rate of the block material. The three-dimensional observation indicated that the experimental block maintained the external geometry, but at the same time successfully altered the graft material into bone. It is suggested that the combination of numerous factors contributed to the bone ingrowth and the novel development could be an alternative bone grafting choice.

14.
Biomed Mater ; 8(3): 035010, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23598427

RESUMEN

Few studies have evaluated the effects of titanium (Ti) surface modifications on polymorphonuclear neutrophils (PMNs). Human PMNs' viability and release of key mediators-such as IL1ß, IL6, TNFα, IL12, IL10, IL4, TGFß1, IL8, IP-10, and Mig-were evaluated on three different Ti surface treatments: (1) machined Ti; (2) alumina-blasted and acid-etched Ti (AB/AE); and (3) calcium phosphate coating of 300-500 nm by ion beam onto the AB/AE Ti surface (CaP). A polystyrene surface was used as a negative control. The PMNs were purified from whole human blood and cultured for 6 h. Cell viability was determined by flow cytometry, and the supernatant was evaluated to determine the levels of cytokines and chemokines. Results showed that the percentage of viable cells was significantly lower on the CaP surface compared to the control (p < 0.05) relative to the other groups. No differences in the levels of IL8, MIG, and IP10 were detected between groups. Significantly higher levels of IL1ß (p = 0.046) and TNFα (p = 0.016) were detected for the CaP surfaces compared to AB/AE surface only. The levels of IL4, IL10, and TGFß1 secreted from the PMNs in the CaP group were significantly lower than in the control and machined groups (p < 0.05) that were statistically comparable to AB/AE. Overall, the addition of a thin CaP coating to the AB/AE Ti surface influenced the secretion profile of pro-inflammatory cytokines due to the higher release of pro-inflammatory cytokines (IL1ß and TNFα) on these surfaces.


Asunto(s)
Fosfatos de Calcio/química , Materiales Biocompatibles Revestidos/química , Neutrófilos/fisiología , Titanio/química , Grabado Ácido Dental , Aleaciones/química , Óxido de Aluminio , Supervivencia Celular , Quimiocinas/biosíntesis , Citocinas/biosíntesis , Humanos , Mediadores de Inflamación/metabolismo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Neutrófilos/citología , Propiedades de Superficie
15.
Biomed Mater ; 8(3): 035002, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23531996

RESUMEN

This study aimed to determine the effect of a bioactive ceramic coating on titanium in the nanothickness range on human osteogenic cells, peripheral blood mononuclear cells (PBMC) and on osteogenic cells co-cultured with PBMC without exogenous stimuli. Cell viability, proliferation, adhesion, cytokine release (IL1ß, TGFß1, IL10 and IL17) and intracellular stain for osteopontin and alkaline phosphatase were assessed. Morphologic evaluation showed smaller and less spread cell aspects in co-culture relative to osteogenic cell culture. Cell viability, proliferation and adhesion kinetics were differently influenced by surface texture/chemistry in culture versus co-culture. Cytokine release was also influenced by the interaction between mononuclear and osteogenic cells (mediators released by mononuclear cells acted on osteogenic cells and vice versa). In general, 'multi-cell type' interactions played a more remarkable role than the surface roughness or chemistry utilized on the in vitro cellular events related to initial stages of bone formation.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Osteogénesis , Titanio/química , Adhesión Celular , Supervivencia Celular , Cerámica/química , Técnicas de Cocultivo , Citocinas/metabolismo , Humanos , Leucocitos Mononucleares/citología , Leucocitos Mononucleares/fisiología , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Osteoblastos/citología , Osteoblastos/fisiología , Propiedades de Superficie
16.
Int J Biomater ; 2013: 354125, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23365578

RESUMEN

The surface energy of the implant surface has an impact on osseointegration. In this study, 2 surfaces: nonwashed resorbable blasting media (NWRBM; control) and Ar-based nonthermal plasma 30 days (Plasma 30 days; experimental), were investigated with a focus on the surface energy. The surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and the chemistry by X-ray photoelectron spectroscopy (XPS). Five adult beagle dogs received 8 implants (n = 2 per surface, per tibia). After 2 weeks, the animals were euthanized, and half of the implants (n = 20) were removal torqued and the other half were histologically processed (n = 20). The bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated on the histologic sections. The XPS analysis showed peaks of C, Ca, O, and P for the control and experimental surfaces. While no significant difference was observed for BIC parameter (P > 0.75), a higher level for torque (P < 0.02) and BAFO parameter (P < 0.01) was observed for the experimental group. The surface elemental chemistry was modified by the plasma and lasted for 30 days after treatment resulting in improved biomechanical fixation and bone formation at 2 weeks compared to the control group.

17.
J Biomed Mater Res A ; 101(1): 98-103, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22826209

RESUMEN

This study investigated the effect of an Argon-based nonthermal plasma (NTP) surface treatment-operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: Calcium-Phosphate (CaP) and CaP + NTP (CaP-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received 2 plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ca, C, O, and P for the CaP and CaP-Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C-C, C-H) with lower levels of oxidized carbon forms. The CaP surface presented atomic percent values of 38, 42, 11, and 7 for C, O, Ca, and P, respectively, and the CaP-Plasma presented increases in O, Ca, and P atomic percent levels at 53, 12, and 13, respectively, in addition to a decrease in C content at 18 atomic percent. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC and BAFO were observed for CaP-Plasma treated surfaces. Surface elemental chemistry was modified by the Ar-based NTP. Ar-based NTP improved bone formation around plateau-root form implants at 3 weeks compared with CaP treatment alone.


Asunto(s)
Argón/farmacología , Fosfatos de Calcio/farmacología , Materiales Biocompatibles Revestidos/farmacología , Implantes Dentales , Implantes Experimentales , Oseointegración/efectos de los fármacos , Gases em Plasma/farmacología , Animales , Perros , Masculino , Microscopía Electrónica de Rastreo , Osteogénesis/efectos de los fármacos
18.
Clin Oral Implants Res ; 24(12): 1375-80, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22925006

RESUMEN

OBJECTIVES: Bone formation and maintenance around implants placed immediately after tooth extraction may be affected by implant surface treatment and compromise long-term esthetic results. This study morphometrically evaluated buccal bone loss and bone-to-implant contact (BIC) of four implant systems placed immediately after tooth extraction in a dog model. MATERIAL AND METHODS: The premolars of eight beagle dogs were bilaterally extracted with a full-thickness flap, and root-form dental implants were placed on the root extraction socket. Implants (n = 16 each) with different surface treatments were placed from sites 1 to 4 and alternated between animals to allow evaluation of the same number of implants at sites and evaluation time points. Implant surface treatments were as follows: anodized, discrete crystalline deposition, SLActive, and microblasted. The left and right side provided implants that stayed for 2 and 4 weeks, respectively. Submerged healing was allowed and bone-to-implant contact (BIC) and buccal bone loss were morphometrically measured. Linear mixed models (P < 0.05) were used to assess differences between groups, across time, and their interaction. RESULTS: Buccal bone loss was observed to approximately double between 2 and 4 weeks (P = 0.01). BIC also increased between 2 and 4 weeks, by 20-25% (P = 0.01). These changes were statistically similar for each surface. CONCLUSION: When placed immediately after tooth extraction, the evaluated histomorphometric parameters vary only with time.


Asunto(s)
Pérdida de Hueso Alveolar/fisiopatología , Implantes Dentales , Carga Inmediata del Implante Dental , Implantes Experimentales , Osteogénesis/fisiología , Animales , Perros , Mandíbula/cirugía , Extracción Dental , Cicatrización de Heridas/fisiología
19.
Int J Biomater ; 2012: 603826, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22969806

RESUMEN

Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA