Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Opt Soc Am A Opt Image Sci Vis ; 40(4): C138-C149, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37132983

RESUMEN

We propose, implement, and validate a new objective method for predicting the trends of visual acuity through-focus curves provided by specific optical elements. The proposed method utilized imaging of sinusoidal gratings provided by the optical elements and the definition of acuity. A custom-made monocular visual simulator equipped with active optics was used to implement the objective method and to validate it via subjective measurements. Visual acuity measurements were obtained monocularly from a set of six subjects with paralyzed accommodation for a naked eye and then that eye compensated by four multifocal optical elements. The objective methodology successfully predicts the trends of the visual acuity through-focus curve for all considered cases. The Pearson correlation coefficient was 0.878 for all tested optical elements, which agrees with results obtained by similar works. The proposed method constitutes an easy and direct alternative technique for the objective testing of optical elements for ophthalmic and optometric applications, which can be implemented before invasive, demanding, or costly procedures on real subjects.

2.
Transl Vis Sci Technol ; 9(3): 6, 2020 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-32704426

RESUMEN

Purpose: We propose and evaluate the modifications of a light sword lens (LSL) to obtain better performance for distance vision while maintaining good operation for near and intermediate vision. Methods: The modifications consisted of assigning angular or circular windows for distance vision while rescaling the LSL profile in the remaining area of the element. The objective performance of the redesigned LSLs was verified numerically by the Strehl ratio and experimentally using correlation coefficients and Michelson contrast. Subjective assessments were provided by monocular visual acuity (VA) and contrast sensitivity (CS) through-focus curves for six patients with paralyzed accommodation. The tested object vergence range was [-4.0, 0.0] diopters (D). All experiments were conducted in a custom-made monocular visual simulator. Results: Computational simulations and objective experiments confirmed the better performance of the modified LSL for the imaging of distant objects. The proposed angular and radial modulations resulted in flat VA and CS through-focus curves, indicating more uniform quality of vision with clearly improved distance vision. The VA provided by the modified LSL profiles showed a maximal improvement of 1.5 lines of acuity with respect to the VA provided by the conventional LSL at distance vision. Conclusions: Optimized LSLs provide better imaging of distant objects while maintaining a large depth of focus. This results in comparable and acceptable quality for distance, intermediate, and near vision. Therefore, the modified LSLs appear to be promising presbyopia correctors. Translational Relevance: The new design of LSL reveals an improved performance for all ranges of vision and becomes a promissory element for a real presbyopia correction in clinical applications.


Asunto(s)
Cristalino , Lentes Intraoculares , Presbiopía , Sensibilidad de Contraste , Humanos , Presbiopía/cirugía , Agudeza Visual
3.
Biomed Opt Express ; 11(1): 40-54, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32010498

RESUMEN

This work presents the first models of light sword intraocular lenses (LS IOLs) with angularly modulated optical power. We performed an experimental, comparative study with multifocal and extended depth of focus intraocular lenses, which are available on the market. The measurements conducted in an original optical bench were utilised for an analysis of point spread functions, elongated foci, modulation transfer functions and the areas defined by them. The LS IOL models perform homogeneous imaging in the whole range of designed defocus. The proposed concept of extended depth of focus seems to be promising for the development of presbyopia-correcting intraocular lenses capable of regaining fully functional vision.

4.
Invest Ophthalmol Vis Sci ; 57(15): 6870-6877, 2016 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-28002561

RESUMEN

Purpose: We present the first physiological evaluation of the use of the light sword lens (LSL) for presbyopia compensation. The LSL is an axially asymmetric optical element designed for imaging with extended depth of focus. Methods: A monocular visual simulator setup is implemented to measure visual acuity (VA). Physiological presbyopia is "mimicked" in human subjects by paralysis of the ciliary muscle, using topical application of a muscarinic antagonist. The effect of a contact lens-configured LSL on the mimicked presbyopia visual system is evaluated by measuring VA as a function of target vergence. The ability of the LSL to compensate presbyopia for 2 photopic luminance values was also analyzed. Results: The average VA values for 11 subjects suggest that the LSL can compensate for presbyopia across a wide range of target vergences for which the LSL was designed (-3 to 0 D). However, the proposed corrector element causes a loss of distance VA. The mean logMAR VA in that target vergence range was 0.07. The VA curves also show that luminance does not affect the expected behavior of the LSL-corrected presbyopic eye. Conclusions: These results indicate that the LSL has significant potential as a visual aid for presbyopia.


Asunto(s)
Lentes de Contacto , Presbiopía/fisiopatología , Agudeza Visual/fisiología , Adolescente , Adulto , Sensibilidad de Contraste/fisiología , Diseño de Equipo , Humanos , Persona de Mediana Edad , Presbiopía/terapia , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA