Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(15)2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39124831

RESUMEN

Background: Atrioventricular node (AVN) ablation is an effective treatment for atrial fibrillation (AF) with uncontrolled ventricular rates despite maximal pharmacological treatment. Intracardiac echocardiography (ICE) can help with visualizing structures, positioning catheters, and guiding the ablation procedure. We compared only fluoroscopy-guided and ICE-guided AVN ablation regarding patients with permanent AF. Methods: Sixty-two consecutive patients underwent AVN ablation were enrolled in our retrospective single-center study (ICE group: 28 patients, Standard group: 34 patients). Procedural data, acute and long-term success rate, and complications were analyzed. Results: ICE guidance for AVN ablation significantly reduced fluoroscopy time (0.30 [0.06; 0.85] min vs. 7.95 [3.23; 6.59] min, p < 0.01), first-to-last ablation time (4 [2; 16.3] min vs. 26.5 [2.3; 72.5] min, p = 0.02), and in-procedure time (40 [34; 55] min vs. 60 [45; 110], p = 0.02). There was no difference in either the total ablation time (199 [91; 436] s vs. 294 [110; 659] s, p = 0.22) or in total ablation energy (8272 [4004; 14,651] J vs. 6065 [2708; 16,406] J, p = 0.28). The acute success rate was similar (ICE: 100% vs. Standard: 94%, p = 0.49) between the groups. Conclusions: In our retrospective trial, ICE-guided AVN ablation reduced fluoroscopy time, procedure time, and first-to-last ablation time. There was no difference in ablation time, total ablation energy, acute and long-term success, and complication rate.

2.
Sci Rep ; 14(1): 16332, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-39009806

RESUMEN

Pulmonary vein isolation (PVI) stands as a widely practiced cardiac ablation procedure on a global scale, conventionally guided by fluoroscopy. The concurrent application of electroanatomical mapping systems (EAMS) and intracardiac echocardiography offers a means to curtail radiation exposure. This study aimed to compare procedural outcomes between conventional and our initial zero-fluoroscopy cases in patients with paroxysmal or persistent atrial fibrillation (AF), undergoing point-by-point PVI. Our prospective observational study included 100 consecutive patients with AF who underwent point-by-point radiofrequency PVI. The standard technique was used in the first 50 cases (Standard group), while the fluoroless technique was used in the subsequent 50 patients (Zero group). The zero-fluoroscopy approach exhibited significantly shorter procedural time (59.6 ± 10.7 min vs. 74.6 ± 13.2 min, p < 0.0001), attributed to a reduced access time (17 [16; 20] min vs. 31 [23; 34.5] min, p < 0.001). Comparable results were found for the number of RF applications, total ablation energy, and left atrial dwelling time. In the Zero group, all procedures were achieved without fluoroscopy, resulting in significantly lower fluoroscopy time (0 [0; 0] sec vs. 132 [100; 160] sec, p < 0.0001) and dose (0 [0; 0] mGy vs. 4.8 [4.1; 8.2] mGy, p < 0.0001). The acute success rate was 100%, with no major complications. Zero-fluoroscopy PVI is feasible, safe, and associated with shorter procedure times compared to the standard approach, even in cases without prior experience in zero-fluoroscopy PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Venas Pulmonares/cirugía , Femenino , Masculino , Fluoroscopía/métodos , Persona de Mediana Edad , Ablación por Catéter/métodos , Estudios Prospectivos , Anciano , Resultado del Tratamiento , Ecocardiografía/métodos
3.
J Clin Med ; 13(4)2024 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-38398342

RESUMEN

(1) Background: During pulmonary vein isolation (PVI) for atrial fibrillation (AF), multipolar mapping catheters (MMC) are often used. We aimed to compare the procedural outcomes of two MMCs, specifically a circular-shaped and a five-spline-shaped MMC. (2) Methods: We enrolled 70 consecutive patients in our prospective, observational trial undergoing PVI procedures for paroxysmal AF. The initial 35 patients underwent PVI procedures with circular-shaped MMC guidance (Lasso Group), and the procedures for the latter 35 cases were performed using five-spline-shaped MMC (PentaRay Group). (3) Results: No significant differences were identified between the two groups in total procedure time (80.2 ± 17.7 min vs. 75.7 ± 14.8 min, p = 0.13), time from femoral vein puncture to the initiation of the mapping (31.2 ± 7 min vs. 28.9 ± 6.8, p = 0.80), mapping time (8 (6; 13) min vs. 9 (6.5; 10.5) min, p = 0.73), duration between the first and last ablation (32 (30; 36) min vs. 33 (26; 40) min, p = 0.52), validation time (3 (2; 4) min vs. 3 (1; 5) min, p = 0.46), first pass success rates (89% vs. 91%, p = 0.71), left atrial dwelling time (46 (37; 53) min vs. 45 (36.5; 53) min, p = 0.56), fluoroscopy data (time: 150 ± 71 s vs. 143 ± 56 s, p = 0.14; dose: 6.7 ± 4 mGy vs. 7.4 ± 4.4 mGy, p = 0.90), total ablation time (1187 (1063; 1534) s vs. 1150.5 (1053; 1393.5) s, p = 0.49), the number of ablations (78 (73; 93) vs. 83 (71.3; 92.8), p = 0.60), and total ablation energy (52,300 (47,265; 66,804) J vs. 49,666 (46,395; 56,502) J, p = 0.35). (4) Conclusions: This study finds comparable procedural outcomes bet-ween circular-shaped and five-spline-shaped MMCs for PVI in paroxysmal AF, supporting their interchangeability in clinical practice for anatomical mapping.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA