Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Kyobu Geka ; 62(2): 112-6, 2009 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-19202929

RESUMEN

Postoperative pulmonary valve regurgitation, stenosis of the right ventricular outflow tract, conduit failure, ventricular septal patch leak, secondary tricuspid valve regurgitation, and various arrhythmias are the major complications that develop after surgical repair of tetralogy of Fallot in adults. A 27-year-old male with pulmonary regurgitation, tricuspid regurgitation, residual ventricular septal defect (VSD), low left ventricular function, and chronic atrial fibrillation underwent tricuspid annuloplasty, pulmonary valve replacement with a stentless aortic valve, VSD patch closure, and right-sided maze procedure, and the postoperative course was uneventful. The cardiothoracic ratio decreased, sinus rhythm was restored, and the patient's complaints were relieved. Reoperation at the optimal time after corrective repair of tetralogy of Fallot in adults may improve the outcome.


Asunto(s)
Fibrilación Atrial/cirugía , Defectos del Tabique Interventricular/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Complicaciones Posoperatorias , Insuficiencia de la Válvula Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Disfunción Ventricular Izquierda/cirugía , Adulto , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Masculino , Reoperación , Factores de Tiempo , Resultado del Tratamiento
2.
Kyobu Geka ; 56(5): 407-10, 2003 May.
Artículo en Japonés | MEDLINE | ID: mdl-12739365

RESUMEN

A 4-month-old female with ventricular septal defect (VSD) and severe pulmonary hypertension (PH) underwent a patch closure for VSD. She could not be weaned from cardiopulmonary bypass (CPB) after the intracardiac repair due to PH crisis. Nitric oxide inhalation therapy during partial CPB enabled her to be weaned from CPB. This therapy could be gradually taped off and quit 7 days after the operation. Nitric oxide inhaled therapy is considered to be an excellent treatment for PH crisis during CPB in congenital cardiac surgery. The causes of PH crisis were also discussed in reference to the date of endothelin-1 (ET-1) measured during the operation.


Asunto(s)
Puente Cardiopulmonar , Endotelina-1/sangre , Defectos del Tabique Interventricular/cirugía , Hipertensión Pulmonar/terapia , Óxido Nítrico/administración & dosificación , Administración por Inhalación , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Defectos del Tabique Interventricular/sangre , Humanos , Hipertensión Pulmonar/complicaciones , Lactante
3.
Jpn J Thorac Cardiovasc Surg ; 48(8): 520-3, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11002584

RESUMEN

A case of leaflet fracture and embolization of a mitral prosthetic valve is described. A 54-year-old man had received mitral valve replacement with an Edwards-Duromedics 29M prosthetic valve, at 10 years ago. Emergency mitral valve replacement was performed because the patient had severe congestive left heart failure with severe acute mitral regurgitation caused by a fracture in one of the mitral valve leaflets. The leaflet, which was fractured into 2 pieces, was removed from the right common iliac artery at 3 months after valve replacement. Visual inspection revealed that the leaflet contained a midline fracture. The fracture originated within a cavitary erosion pit near the major radius of the leaflet. The patient recovered from acute renal failure, requiring hemodialysis for 80 days, and is currently without complaints. We have used a Duromedics mitral valve in 11 patients, from April 1987 to April 1988. No subsequent valve failure has occurred. The diagnosis, treatment and cause of a mechanical valve fracture are discussed.


Asunto(s)
Prótesis Valvulares Cardíacas , Embolia/etiología , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral , Insuficiencia de la Válvula Mitral/etiología , Falla de Prótesis , Reoperación
4.
J Cardiovasc Surg (Torino) ; 40(1): 165-7, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10221407

RESUMEN

Portable percutaneous cardiopulmonary support (PCPS) with heparin-coated circuits and a biopump was employed in a patient who had a massive pulmonary embolism with circulatory collapse after stripping of varicosities of the leg. Emergency pulmonary embolectomy was successfully performed. The main pulmonary incision was facilitated by cross-clamping of the main pulmonary arterial root. The bypass circuit was kept closed, and used with the normothermic beating heart without converting to conventional total cardiopulmonary bypass. Blood flow from the lung was removed by pump suction, stored in the reservoir, and intermittently returned to the venous circulation. Heparin was added to the circuits to keep the activated clotting time greater than 300 sec. In massive pulmonary embolism, PCPS is useful for preoperative, intraoperative, and postoperative support.


Asunto(s)
Puente Cardiopulmonar/métodos , Embolia Pulmonar/cirugía , Enfermedad Aguda , Femenino , Humanos , Persona de Mediana Edad
5.
Jpn J Thorac Cardiovasc Surg ; 46(1): 85-90, 1998 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-9513531

RESUMEN

We reported two cases of thrombosed, Stanford A type acute aortic dissection, initially without intimal tear, later operated upon because of recrudescence. They admitted to our hospital with the symptoms of aortic dissection. Early examination of computed tomography and angiography demonstrated thrombosed type A aortic dissection showing a normal aortic figure, although accompanied by pericardial effusion, that was drainaged. Under strict BP control, however, repeat CT examination revealed recrudescent dissection of ascending aorta, making dissecting aneurysms. Graft replacement of ascending aorta was performed, on the 55th and 153th day after admission, and they were discharged.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Trombosis/cirugía , Anciano , Femenino , Humanos , Masculino , Derrame Pericárdico/etiología , Trombosis/etiología
6.
Kyobu Geka ; 49(6): 471-4, 1996 Jun.
Artículo en Japonés | MEDLINE | ID: mdl-8847846

RESUMEN

This is a case report of a 23 year old female involved in a car accident that caused blunt trauma to the patient. First of all, she was found to have cardiac tamponade when the abdomen was explored to suture and to put the gaze compression on for hemostasis of the ruptured liver. Then, she was brought to our institution by the ambulance. Upon the exploration of the heart under standby of extracorporal circulation (ECC), small multiple lacerations were found at the junction of the right atrium and superior vena cava. These were sutured directly to close without ECC. On the 2nd postoperative day, she was bought to the OR again to removal of the gaze tamponade from the ruptured liver and to complete hemostasis. The patient was discarded 35 days after admission.


Asunto(s)
Lesiones Cardíacas/cirugía , Hígado/lesiones , Hígado/cirugía , Heridas no Penetrantes/cirugía , Accidentes de Tránsito , Adulto , Femenino , Atrios Cardíacos/lesiones , Humanos , Rotura
7.
Kyobu Geka ; 48(8): 624-7, 1995 Jul.
Artículo en Japonés | MEDLINE | ID: mdl-7643495

RESUMEN

Recent policy for the intracardiac repair of complete atrioventricular septal defect (CAVSD) is demonstrated on the basis of the following theoretical background. In the normal heart, the originating portion of the ascending aorta and the crux intrude between the mitral and tricuspid orifices each from the anterior and from the posterior, separating both the orifices together with a short fibrous septal junction. In CAVSD, however, the common A-V orifice takes an elliptic form without any septal junction. It is considered beneficial, therefore, to surgically produce a short septal junction by using a smaller patch to close the ventricular portion of the AVSD. When the left lateral leaflet is larger, two leaflets valve plasty is suggested and when it is smaller, three leaflets valve plasty is suggested to reconstruct the left-sided A-V valve, although competence of the valve leaflets must be finally secured by doing repeated water injection tests. The size of the orifices of the reconstructed left-sided as well as right-sided A-V valve should also be confirmed not to be stenotic by using Hegar sizers. Since 1991, we have applied this surgical concept in 7 patients with CAVSD. Postoperatively, there was no left A-V valve regurgitation in one and slight regurgitation remained in 6 patients. The result is considered to be satisfactory. Although one patient died due to PH crisis, the cause of death was not related to valve regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Defectos de la Almohadilla Endocárdica/cirugía , Válvulas Cardíacas/cirugía , Preescolar , Humanos , Lactante , Métodos
8.
Kyobu Geka ; 48(2): 133-6, 1995 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-7897882

RESUMEN

A one year and 6 months old female infant was admitted to our department for a radical correction of a truncus arteriosus (Collett-Edwards type II). She also had a peripheral pulmonary stenosis and Holt-Oram syndrome. Under a cardiopulmonary bypass with deep hypothermia, PFO was closed directly. First of all, the pulmonary arteries were dissected from the aorta, the defect of the aorta was closed directly and VSD was closed with Dacron fabric patch. The reconstruction of the pulmonary arteries were performed with valved conduit which consisted of Dacron graft and 14 mm Björk-Shily valve. The post-operative course was uneventful. Cardiac catheterization study, done 77 days after surgery, revealed 44 mmHg of pressure gradient between RV outflow tract and right PA. The patient was doing well and two years have passed since the surgery. She should be observed carefully at the out-patient clinic due to the mechanical valve and the presence of pressure gradient at RV outflow tract.


Asunto(s)
Deformidades Congénitas de la Mano , Defectos del Tabique Interventricular/cirugía , Arteria Pulmonar/anomalías , Tronco Arterial Persistente/cirugía , Prótesis Vascular , Constricción Patológica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Humanos , Lactante , Arteria Pulmonar/cirugía , Síndrome
9.
Kyobu Geka ; 47(3): 235-7, 1994 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-8114395

RESUMEN

This is a case report of 8-years-old boy, who was diagnosed mitral regurgitation, secundum type of atrial septal defect and annulo-aortic ectasia in association with Marfan syndrome. His diagnosis was confirmed at the age of 6 years when cardiac catheterization was carried out. Atrial septal defect was closed using PTFE patch (0.2 mm in thickness). His diseased mitral valve was replaced with CarboMedics prosthesis 27 mm in diameter. Because of intact aortic valvular function, we left the ectatic aorta alone at present time for future procedure. His postoperative course was uneventful. He is active and doing well at present and has been followed-up at the outpatient clinic routinely. He might be having to require AVR and graft implantation for ectatic ascending aorta.


Asunto(s)
Defectos del Tabique Interatrial/cirugía , Prótesis Valvulares Cardíacas , Síndrome de Marfan/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Niño , Defectos del Tabique Interatrial/complicaciones , Humanos , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA