Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Am J Physiol Endocrinol Metab ; 325(3): E192-E206, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37436961

RESUMEN

Exercise can cause dangerous fluctuations in blood glucose in people living with type 1 diabetes (T1D). Aerobic exercise, for example, can cause acute hypoglycemia secondary to increased insulin-mediated and noninsulin-mediated glucose utilization. Less is known about how resistance exercise (RE) impacts glucose dynamics. Twenty-five people with T1D underwent three sessions of either moderate or high-intensity RE at three insulin infusion rates during a glucose tracer clamp. We calculated time-varying rates of endogenous glucose production (EGP) and glucose disposal (Rd) across all sessions and used linear regression and extrapolation to estimate insulin- and noninsulin-mediated components of glucose utilization. Blood glucose did not change on average during exercise. The area under the curve (AUC) for EGP increased by 1.04 mM during RE (95% CI: 0.65-1.43, P < 0.001) and decreased proportionally to insulin infusion rate (0.003 mM per percent above basal rate, 95% CI: 0.001-0.006, P = 0.003). The AUC for Rd rose by 1.26 mM during RE (95% CI: 0.41-2.10, P = 0.004) and increased proportionally with insulin infusion rate (0.04 mM per percent above basal rate, CI: 0.03-0.04, P < 0.001). No differences were observed between the moderate and high resistance groups. Noninsulin-mediated glucose utilization rose significantly during exercise before returning to baseline roughly 30-min postexercise. Insulin-mediated glucose utilization remained unchanged during exercise sessions. Circulating catecholamines and lactate rose during exercise despite relatively small changes observed in Rd. Results provide an explanation of why RE may pose a lower overall risk for hypoglycemia.NEW & NOTEWORTHY Aerobic exercise is known to cause decreases in blood glucose secondary to increased glucose utilization in people living with type 1 diabetes (T1D). However, less is known about how resistance-type exercise impacts glucose dynamics. Twenty-five participants with T1D performed in-clinic weight-bearing exercises under a glucose clamp. Mathematical modeling of infused glucose tracer allowed for quantification of the rate of hepatic glucose production as well as rates of insulin-mediated and noninsulin-mediated glucose uptake experienced during resistance exercise.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Entrenamiento de Fuerza , Humanos , Glucosa , Insulina , Glucemia , Ejercicio Físico , Ácido Láctico
3.
IEEE Trans Med Imaging ; 42(11): 3219-3228, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37216244

RESUMEN

We introduce a new concept of panoramic retinal (panretinal) optical coherence tomography (OCT) imaging system with a 140° field of view (FOV). To achieve this unprecedented FOV, a contact imaging approach was used which enabled faster, more efficient, and quantitative retinal imaging with measurement of axial eye length. The utilization of the handheld panretinal OCT imaging system could allow earlier recognition of peripheral retinal disease and prevent permanent vision loss. In addition, adequate visualization of the peripheral retina has a great potential for better understanding disease mechanisms regarding the periphery. To the best of our knowledge, the panretinal OCT imaging system presented in this manuscript has the widest FOV among all the retina OCT imaging systems and offers significant values in both clinical ophthalmology and basic vision science.


Asunto(s)
Retina , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Retina/diagnóstico por imagen
4.
JAMA Ophthalmol ; 2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36227622

RESUMEN

Importance: Accurate diagnosis of retinopathy of prematurity (ROP) is essential to provide timely treatment and reduce the risk of blindness. However, the components of an ROP examination are subjective and qualitative. Objective: To evaluate whether optical coherence tomography (OCT)-derived retinal thickness measurements at the vascular-avascular junction are associated with clinical diagnosis of ROP stage. Design, Setting, and Participants: This cross-sectional longitudinal study compared OCT-based ridge thickness calculated from OCT B-scans by a masked examiner to the clinical diagnosis of 2 masked examiners using both traditional stage classifications and a more granular continuous scale at the neonatal intensive care unit (NICU) of Oregon Health & Science University (OHSU) Hospital. Infants who met ROP screening criteria in the OHSU NICU between June 2021 and April 2022 and had guardian consent were included. One OCT volume and en face image per patient per eye showing at least 1 to 2 clock hours of ridge were included in the final analysis. Main Outcomes and Measures: Comparison of OCT-derived ridge thickness to the clinical diagnosis of ROP stage using an ordinal and continuous scale. Repeatability was assessed using 20 repeated examinations from the same visit and compared using intraclass correlation coefficient (ICC) and coefficient of variation (CV). Comparison of ridge thickness with ordinal categories was performed using generalized estimating equations and with continuous stage using Spearman correlation. Results: A total of 128 separate OCT eye examinations from 50 eyes of 25 patients were analyzed. The ICC was 0.87 with a CV of 7.0%. Higher ordinal disease classification was associated with higher axial ridge thickness on OCT, with mean (SD) thickness measurements of 264.2 (11.2) µm (P < .001), 334.2 (11.4) µm (P < .001), and 495.0 (32.2) µm (P < .001) for stages 1, 2, and 3, respectively and with continuous stage labels (ρ = 0.739, P < .001). Conclusions and Relevance: These results suggest that OCT-based quantification of peripheral stage in ROP may be an objective and quantitative biomarker that may be useful for clinical diagnosis and longitudinal monitoring and may have implications for disease classification in the future.

5.
Front Med (Lausanne) ; 9: 860371, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35860728

RESUMEN

Optical coherence tomography (OCT) has changed the standard of care for diagnosis and management of macular diseases in adults. Current commercially available OCT systems, including handheld OCT for pediatric use, have a relatively narrow field of view (FOV), which has limited the potential application of OCT to retinal diseases with primarily peripheral pathology, including many of the most common pediatric retinal conditions. More broadly, diagnosis of all types of retinal detachment (exudative, tractional, and rhegmatogenous) may be improved with OCT-based assessment of retinal breaks, identification of proliferative vitreoretinopathy (PVR) membranes, and the pattern of subretinal fluid. Intraocular tumors both benign and malignant often occur outside of the central macula and may be associated with exudation, subretinal and intraretinal fluid, and vitreoretinal traction. The development of wider field OCT systems thus has the potential to improve the diagnosis and management of myriad diseases in both adult and pediatric retina. In this paper, we present a case series of pediatric patients with complex vitreoretinal pathology undergoing examinations under anesthesia (EUA) using a portable widefield (WF) swept-source (SS)-OCT device.

6.
Biomed Opt Express ; 13(2): 950-961, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35284155

RESUMEN

Photoreceptor loss and resultant thinning of the outer nuclear layer (ONL) is an important pathological feature of retinal degenerations and may serve as a useful imaging biomarker for age-related macular degeneration. However, the demarcation between the ONL and the adjacent Henle's fiber layer (HFL) is difficult to visualize with standard optical coherence tomography (OCT). A dedicated OCT system that can precisely control and continuously and synchronously update the imaging beam entry points during scanning has not been realized yet. In this paper, we introduce a novel imaging technology, Volumetric Directional OCT (VD-OCT), which can dynamically adjust the incident beam on the pupil without manual adjustment during a volumetric OCT scan. We also implement a customized spoke-circular scanning pattern to observe the appearance of HFL with sufficient optical contrast in continuous cross-sectional scans through the entire volume. The application of VD-OCT for retinal imaging to exploit directional reflectivity properties of tissue layers has the potential to allow for early identification of retinal diseases.

7.
Ophthalmol Sci ; 2(1)2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35128508

RESUMEN

OBJECTIVE: To determine whether handheld widefield optical coherence tomography (OCT) can be used to document retinopathy of prematurity (ROP) stage while using scleral depression to improve peripheral views. DESIGN: Prospective observational study. PARTICIPANTS: Consecutive neonates admitted to the neonatal intensive care unit (NICU) in a single academic medical center who also met criteria for ROP screening and consented for research imaging. METHODS: Scleral depression was combined with widefield OCT using an investigational 400-kHz, 55-degree field of view handheld OCT during routine ROP screening from October 28, 2020 to March 03, 2021. MAIN OUTCOME MEASURES: Acquisition of en face and B-scan imaging of the peripheral retina to objectively assess early vitreoretinal pathology, including the demarcation between vascularized and anterior avascular retina, the presence of early ridge formation, and small neovascular tufts. RESULTS: Various stages of ROP were detected using a rapid acquisition OCT system. In one neonate, serial OCT imaging over a five-week period demonstrated accumulation of neovascular tufts with progression to stage 3 ROP with extraretinal fibrovascular proliferation along the ridge. Videography of this technique is included in this report for instructional purposes. CONCLUSIONS: Serial examinations using widefield OCT and scleral depression is feasible and may improve detection and documentation of ROP disease progression. Earlier detection of ROP-related proliferation may prevent vitreoretinal traction, retinal detachment, and blindness.

8.
Opt Lett ; 46(23): 5878-5881, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34851913

RESUMEN

We demonstrate a handheld swept-source optical coherence tomography (OCT) system with a 400 kHz vertical-cavity surface-emitting laser (VCSEL) light source, a non-contact approach, and an unprecedented single shot 105° field of view (FOV). We also implemented a spiral scanning pattern allowing real-time visualization with improved scanning efficiency. To the best of our knowledge, this is the widest FOV achieved in a portable non-contact OCT retinal imaging system to date. Improvements to the FOV may aid the evaluation of retinal diseases such as retinopathy of prematurity, where important vitreoretinal changes often occur in the peripheral retina.


Asunto(s)
Enfermedades de la Retina , Tomografía de Coherencia Óptica , Humanos , Recién Nacido , Rayos Láser , Retina/diagnóstico por imagen
9.
Front Pediatr ; 9: 797684, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35118032

RESUMEN

Recent advances in portable optical coherence tomography (OCT) and OCT angiography (OCTA) have resulted in wider fields of view (FOV) and shorter capture times, further expanding the potential clinical role of OCT technology in the diagnosis and management of retinopathy of prematurity (ROP). Using a prototype, handheld OCT device, retinal imaging was obtained in non-sedated infants in the neonatal intensive care unit (NICU) as well as sedated infants in the operating room of Oregon Health & Science University (OHSU) Hospital. In this observational study, we provide an overview of potential advantages of OCT-based disease assessment in ROP. We observed that next-generation OCT imaging (a) may be sufficient for objective diagnosis and zone/stage/plus disease categorization, (b) allows for minimally-invasive longitudinal monitoring of disease progression and post-treatment course, (c) provides three-dimensional mapping of the vitreoretinal interface, and (d) with OCTA, enables dye-free visualization of normal and pathologic vascular development.

10.
Am J Physiol Endocrinol Metab ; 320(3): E425-E437, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33356994

RESUMEN

Aerobic exercise in type 1 diabetes (T1D) causes rapid increase in glucose utilization due to muscle work during exercise, followed by increased insulin sensitivity after exercise. Better understanding of these changes is necessary for models of exercise in T1D. Twenty-six individuals with T1D underwent three sessions at three insulin rates (100%, 150%, 300% of basal). After 3-h run-in, participants performed 45 min aerobic exercise (moderate or intense). We determined area under the curve for endogenous glucose production (AUCEGP) and rate of glucose disappearance (AUCRd) over 45 min from exercise start. A novel application of linear regression of Rd across the three insulin sessions allowed separation of insulin-mediated from non-insulin-mediated glucose uptake before, during, and after exercise. AUCRd increased 12.45 mmol/L (CI = 10.33-14.58, P < 0.001) and 13.13 mmol/L (CI = 11.01-15.26, P < 0.001) whereas AUCEGP increased 1.66 mmol/L (CI = 1.01-2.31, P < 0.001) and 3.46 mmol/L (CI = 2.81-4.11, P < 0.001) above baseline during moderate and intense exercise, respectively. AUCEGP increased during intense exercise by 2.14 mmol/L (CI = 0.91-3.37, P < 0.001) compared with moderate exercise. There was significant effect of insulin infusion rate on AUCRd equal to 0.06 mmol/L per % above basal rate (CI = 0.05-0.07, P < 0.001). Insulin-mediated glucose uptake rose during exercise and persisted hours afterward, whereas non-insulin-mediated effect was limited to the exercise period. To our knowledge, this method of isolating dynamic insulin- and non-insulin-mediated uptake has not been previously employed during exercise. These results will be useful in informing glucoregulatory models of T1D. The study has been registered at www.clinicaltrials.gov as NCT03090451.NEW & NOTEWORTHY Separating insulin and non-insulin glucose uptake dynamically during exercise in type 1 diabetes has not been done before. We use a multistep process, including a previously described linear regression method, over three insulin infusion sessions, to perform this separation and can graph these components before, during, and after exercise for the first time.


Asunto(s)
Diabetes Mellitus Tipo 1/metabolismo , Ejercicio Físico/fisiología , Glucosa/farmacocinética , Insulina/fisiología , Adolescente , Adulto , Glucemia/metabolismo , Femenino , Humanos , Hiperinsulinismo/metabolismo , Hipoglucemia/metabolismo , Insulina/administración & dosificación , Insulina/metabolismo , Resistencia a la Insulina/fisiología , Masculino , Persona de Mediana Edad , Esfuerzo Físico/fisiología , Adulto Joven
11.
Int J Cancer ; 92(3): 421-5, 2001 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-11291081

RESUMEN

Peripheral gammadelta T cells derived from healthy donors were found to exhibit cytotoxicity against a variety of tumor cell lines in vitro, including CNE2, which was established from nasopharyngeal carcinoma (NPC). The anti-tumor effects were further studied in a mouse model. Control nude mice inoculated s.c. with 5 x 10(6) CNE2 cells regularly developed hypodermal tumors, which progressively increased in size, and animals had a mean survival of 35 +/- 3.4 days. Tumor growth was arrested and tumor size was reduced after animals were infused with 5 x 10(7) gammadelta T cells derived from a healthy donor. The anti-tumor effects were temporary, however, and tumor growth was resumed after about 1 week in a group of the animals that had been given a single dose of gammadelta T cells. In another group of animals given 2 doses of gammadelta cells 1 week apart, resumption of tumor growth was delayed for a further week. Mean survival of the 2 groups was increased to 61 +/- 15.7 and 74 +/- 12.9 days, respectively. Immunohistology revealed an accumulation of infused cells in tumors attended by focal tumor necrosis in specimens taken 2 days after infusion. Infiltrative cells virtually disappeared from tumor tissues 6 days after infusion, accompanied by increased mitotic indices of tumor cells. These temporal relationships suggested that the accumulation of infused gammadelta T cells in hypodermal tumors was responsible for the observed anti-tumor effects.


Asunto(s)
Inmunoterapia , Neoplasias Experimentales/terapia , Linfocitos T/inmunología , Animales , Modelos Animales de Enfermedad , Linfocitos Infiltrantes de Tumor/inmunología , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Trasplante de Neoplasias , Neoplasias Experimentales/inmunología , Neoplasias Experimentales/patología , Receptores de Antígenos de Linfocitos T gamma-delta/análisis , Linfocitos T/fisiología , Células Tumorales Cultivadas
12.
Appl Opt ; 38(15): 3409-16, 1999 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-18319939

RESUMEN

The utility of the one-beam cross-correlation dynamic light-scattering system for sizing small particles in suspension was previously limited by its small-intensity signal-to-baseline ratio for strongly turbid suspensions. We describe three improvements in the optical system and sample cell that raise the ratio to a value comparable with that of other cross-correlation dynamic light-scattering systems. These improvements are (i) using a square cross-sectional sample cell to minimize the attenuation of the incident beam and singly scattered light, (ii) placing a 200-microm-wide slit between the sample cell and the detector fibers to mask off the region of weak single scattering and strong multiple scattering from the detectors' field of view, and (iii) aligning the center of the detectors' field of view with the region of strongest single scattering. We analyze a number of suspensions of polystyrene latex spheres with a diameter between 65 and 562 nm in water using this improved one-beam instrument and find that the measured radius is determined in a 2-min data collection time to better than +/-10% for volume fractions of the suspended polystyrene latex spheres up to a few percent.

13.
Appl Opt ; 36(30): 7551-8, 1997 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-18264268

RESUMEN

We describe a new method for characterizing particles in turbid media by cross correlating the scattered intensity fluctuations at two nearby points in the far field. The cross-correlation function selectively emphasizes single scattering over multiple scattering. The usual dynamic light-scattering capability of inferring particle size from decay rate is thus extended to samples that are so turbid as to be visually opaque. The method relies on single-scattering speckle being physically larger than multiple-scattering speckle. With a suitable optical geometry to select nearby points in the far field or equivalently slightly different scattering wave vectors (of the same magnitude), the multiple-scattering contribution to the cross-correlation function may be reduced and in some cases rendered insignificant. Experimental results demonstrating the feasibility of this approach are presented.

14.
Appl Opt ; 36(30): 7601-4, 1997 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-18264274

RESUMEN

We have developed a fiber-optics surface-light-scattering spectrometer completely designed with optical fiber components. To the best of our knowledge, this is the first demonstration of a noninvasive measurement of the surface tension and the viscosity of simple liquid-vapor interfaces with a fiber-optics-based sensor system. With this approach we obtain a compact size, a significant increase in the signal-to-noise ratio, and the ability to select from a continuum of wave vectors.

15.
Appl Opt ; 36(30): 7605-14, 1997 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-18264275

RESUMEN

A hybrid reflection-transmission surface light-scattering instrumental design is presented, examined theoretically, and tested experimentally. The purpose of the design is to reduce the sensitivity of the instrument to vibration in general and surface sloshing in particular while sacrificing little performance. Traditional optical arrangements and two new optical configurations with varying trade-offs between slosh resistance and instrumental simplicity and accuracy are examined by use of Fourier optics methods. The most promising design was constructed and tested with acetone, ethanol, and water as subject fluids. The test involved backcalculation of the wave number of the capillary wave examined with the known physical parameters for the test fluids. The agreement of the computed wave number was +/-1.4%.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA