Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(3)2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38339729

RESUMEN

(1) Background: An optical simulator able to provide a repeatable signal with desired characteristics as an input to a photoplethysmographic (PPG) device is presented in order to compare the performance of different PPG devices and also to test the devices with PPG signals available in online databases. (2) Methods: The optical simulator consists of an electronic board containing a photodiode and LEDs at different wavelengths in order to simulate light reflected by the body; the PPG signal taken from the chosen database is reproduced by the electronic board, and the board is used to test a wearable PPG medical device in the form of earbuds. (3) Results: The PPG device response to different average and peak-to-peak signal amplitudes is shown in order to assess the device sensitivity, and the fidelity in tracking the actual heart rate is also investigated. (4) Conclusions: The developed optical simulator promises to be an affordable, flexible, and reliable solution to test PPG devices in the lab, allowing the testing of their actual performances thanks to the possibility of using PPG databases, thus gaining useful and significant information before on-the-field clinical trials.


Asunto(s)
Algoritmos , Fotopletismografía , Frecuencia Cardíaca/fisiología , Artefactos , Bases de Datos Factuales , Procesamiento de Señales Asistido por Computador
2.
Sensors (Basel) ; 23(8)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37112460

RESUMEN

A frequency-modulated continuous-wave radar for short-range target imaging, assembling a transceiver, a PLL, an SP4T switch, and a serial patch antenna array, was realized. A new algorithm based on a double Fourier transform (2D-FT) was developed and compared with the delay and sum (DAS) and multiple signal classification (MUSIC) algorithms proposed in the literature for target detection. The three reconstruction algorithms were applied to simulated canonical cases evidencing radar resolutions close to the theoretical ones. The proposed 2D-FT algorithm exhibits an angle of view greater than 25° and is five times faster than DAS and 20 times faster than the MUSIC one. The realized radar shows a range resolution of 55 cm and an angular resolution of 14° and is able to correctly identify the positions of single and multiple targets in realistic scenarios, with errors lower than 20 cm.

3.
Sensors (Basel) ; 22(9)2022 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-35590917

RESUMEN

Microwave imaging is an active area of research that has garnered interest over the past few years. The main desired improvements to microwave imaging are related to the performances of radiating systems and identification algorithms. To achieve these improvements, antennas suitable to guarantee demanding requirements are needed. In particular, they must operate in close proximity to the objects under examination, ensure an adequate bandwidth, as well as reduced dimensions and low production costs. In addition, in near-field microwave imaging systems, the antenna should provide an ultra-wideband (UWB) response. Given the relevance of the foreseen applications, many UWB antenna designs for microwave imaging applications have been proposed in the literature. In this paper, a comprehensive review of different UWB antenna designs for near-field microwave imaging is presented. The antennas are classified according to the manufacturing technology and radiative performances. Particular attention is also paid to the radiation mechanisms as well as the techniques used to reduce the size and improve the bandwidth.


Asunto(s)
Imágenes de Microonda , Algoritmos , Costos y Análisis de Costo , Diagnóstico por Imagen/métodos , Microondas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA