Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
2.
Heart ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39209438

RESUMEN

BACKGROUND: The best management of symptomatic patients with low-gradient (LG) severe aortic stenosis (AS) and preserved left ventricular ejection fraction (LVEF) has not been established. The Randomised study for the Optimal Treatment of symptomatic patients with low-gradient severe Aortic valve Stenosis (ROTAS) trial aimed to assess the superiority of aortic valve replacement (AVR) versus medical treatment (MT) in this specific group of AS patients. METHODS: Patients with symptomatic LG severe AS and preserved LVEF (>50%) underwent dobutamine stress echocardiography and/or CT-aortic calcium score to confirm AS severity and were then randomised 1:1 to AVR or MT. The primary endpoint was a composite of overall death and/or cardiovascular hospitalisation. RESULTS: The ROTAS study was stopped early because of insufficient recruitment. In the end, only 52 patients (age 79±7 years; women 54%; NYHA III-IV 27%; median STS score 3.3%) were included in the study. During follow-up (mean: 14±7 months), the primary endpoint occurred in 12 (23%) patients. Compared with MT, AVR was not associated with a significant prognostic benefit (events: 5/26 (19%) vs 7/26 (27%) (HR 0.76, 95% CI 0.24 to 2.39, p=0.63). During follow-up, 11 (42%) patients in the MT group developed class I criteria for AVR or severe symptoms justifying a cross-over to the AVR group. CONCLUSIONS: Because of the small number of included patients and short follow-up the ROTAS trial was underpowered and unable to demonstrate a difference in the study endpoint between treatment arms. In patients in the MT arm, a regular echocardiographic and clinical assessment might be useful to disclose those developing class I indications of AVR or severe AS-related symptoms. TRIAL REGISTRATION NUMBER: NCT01835028.

4.
EuroIntervention ; 20(14): e845-e864, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007831

RESUMEN

Transcatheter aortic valve implantation (TAVI) is now utilised as a less invasive alternative to surgical aortic valve replacement (SAVR) across the whole spectrum of surgical risk. Long-term durability of the bioprosthetic valves has become a key goal of TAVI as this procedure is now considered for younger and lower-risk populations. The purpose of this article is to present a state-of-the-art overview on the definition, aetiology, risk factors, mechanisms, diagnosis, clinical impact, and management of bioprosthetic valve dysfunction (BVD) and failure (BVF) following TAVI with a comparative perspective versus SAVR. Structural valve deterioration (SVD) is the main factor limiting the durability of the bioprosthetic valves used for TAVI or SAVR, but non-structural BVD, such as prosthesis-patient mismatch and paravalvular regurgitation, as well as valve thrombosis or endocarditis may also lead to BVF. The incidence of BVF related to SVD or other causes is low (<5%) at midterm (5- to 8-year) follow-up and compares favourably with that of SAVR. The long-term follow-up data of randomised trials conducted with the first generations of transcatheter heart valves also suggest similar valve durability in TAVI versus SAVR at 10 years, but these trials suffer from major survivorship bias, and the long-term durability of TAVI will need to be confirmed by the analysis of the low-risk TAVI versus SAVR trials at 10 years.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Factores de Riesgo , Bioprótesis , Estenosis de la Válvula Aórtica/cirugía , Falla de Prótesis , Resultado del Tratamiento , Diseño de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
5.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 396-407, mayo 2024. tab, graf
Artículo en Español | IBECS | ID: ibc-JHG-73

RESUMEN

Introducción y objetivos: Existen pocos datos acerca del impacto pronóstico de una clase funcional NYHA III-IV después del implante percutáneo de válvula aórtica (TAVI). El objetivo del estudio fue determinar la incidencia, los predictores y las implicaciones pronósticas de una clase NYHA III-IV al mes del TAVI.MétodosEstudio multicéntrico que incluyó a 3.462 pacientes sometidos a TAVI que recibieron dispositivos de nueva generación. Se compararon pacientes en clase funcional NYHA I-II frente a pacientes en clase NYHA III-IV al mes de seguimiento. Los predictores de clase NYHA III-IV a un mes se identificaron mediante regresión logística multivariante. La supervivencia se evaluó con el método de Kaplan-Meier y los factores asociados a peor pronóstico se identificaron mediante la regresión de Cox.ResultadosLa edad media de la población de estudio era de 80,3±7,3 años, con el 47% de mujeres y un valor mediano en la escala de la Society of Thoracic Surgeons del 3,8% [IQR, 2,5-5,8]). Un total de 208 pacientes (6%) presentaron NYHA III-IV al mes del TAVI. Los predictores de NYHA III-IV al mes fueron: NYHA basal III-IV (OR=1,76; IC95%, 1,08-2,89; p=0,02), enfermedad pulmonar obstructiva crónica (OR=1,80; IC95%, 1,13-2,83; p=0,01) e insuficiencia mitral severa post-TAVI (OR=2,00; IC95%, 1,21-3,31; p<0,01). Los pacientes en NYHA III-IV al mes del TAVI tenían un mayor riesgo de muerte (HR=3,68; IC95%, 2,39-5,70; p<0,01) y hospitalización por insuficiencia cardiaca (HR=6,00; IC95%, 3,76-9,60; p<0,01) durante el año que siguió al TAVI. (AU)


Introduction and objectives: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR.MethodsThis multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis.ResultsThe mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. (AU)


Asunto(s)
Humanos , Válvula Aórtica/cirugía , Complicaciones Posoperatorias , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estudios de Seguimiento , Factores de Riesgo
6.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Anciano , Estudios Prospectivos , Estenosis de la Válvula Aórtica/cirugía , Falla de Prótesis , Diseño de Prótesis , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Oclusión Coronaria/cirugía , Complicaciones Posoperatorias/epidemiología
7.
Eur Heart J Cardiovasc Imaging ; 25(9): 1276-1286, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-38693866

RESUMEN

AIMS: Evaluation of left and right ventricular (RV) longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and RV longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30 days and 1 year after AVR. METHODS AND RESULTS: Left ventricular (LV) longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER 2A surgical AVR (SAVR) arm (n = 985) and from the PARTNER 2 SAPIEN 3 registry (n = 719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline was associated with increased risk of the composite of death, hospitalization, and stroke at 5 years [adjusted hazard ratios (HRs) for LV LS < 15%: 1.24, 95% confidence interval (CI) 1.05-1.45, P = 0.001; TAPSE < 14 mm: 1.44, 95% CI 1.21-1.73, P < 0.001; RV-PA coupling < 0.55 mm/mmHg: 1.32, 95% CI 1.07-1.63, P = 0.011]. Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5 years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95% CI 1.08-1.68, P = 0.009) but not with TAVR (HR: 1.12, 95% CI 0.88-1.42). Lower RV-PA coupling at 30 days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30 days were associated with inferior clinical outcomes at 5 years. In patients with LVEF < 50%, TAVR was associated with superior 5-year outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Sistema de Registros , Humanos , Masculino , Femenino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Medición de Riesgo , Sístole , Anciano de 80 o más Años , Resultado del Tratamiento , Volumen Sistólico/fisiología , Ecocardiografía , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
8.
Arch Cardiovasc Dis ; 117(6-7): 433-440, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38797639

RESUMEN

BACKGROUND: Acute myocarditis usually presents as chest pain with rising troponin and normal coronary arteries. Despite frequent favourable evolution at the acute phase, it is associated with heart failure and ventricular rhythm disorders, and is considered the leading cause of sudden cardiac death in young, apparently healthy, adults. There are no specific recommendations for acute myocarditis diagnosis and management, only expert consensus, given the lack of large databases. AIM: The main objective is to describe the contemporary presentation of acute myocarditis, its management and in-hospital outcomes. Secondary objectives are to investigate survival and event-free survival for up to 10years of follow-up, the determinants of prognosis, the modalities of treatment and follow-up and the gaps between expert consensus and real-life management. METHODS: MyocarditIRM is a prospective multicentre cohort that enrolled 803 consecutive patients with acute myocarditis in 49 participating centres in France between 01 May 2016 and 28 February 2019. The diagnosis of acute myocarditis was acknowledged by cardiac magnetic resonance, using the Lake Louise Criteria. Exclusion criteria were age<18years, lack of health coverage, contraindication to cardiac magnetic resonance and refusal to participate. Detailed information was collected prospectively, starting at admission. Cardiac magnetic resonance imaging (diagnosis and follow-up) is analysed centrally by the certified core laboratory IHU ICAN. Ten years of follow-up for each patient is ensured by linking with the French National Health Database, and includes information on death, hospital admissions, major clinical events and drug consumption. CONCLUSION: This prospective cohort with long-term follow-up represents the largest database on acute myocarditis worldwide, and will improve knowledge about its presentation, management and outcomes.


Asunto(s)
Miocarditis , Valor Predictivo de las Pruebas , Humanos , Miocarditis/diagnóstico por imagen , Miocarditis/terapia , Miocarditis/mortalidad , Miocarditis/diagnóstico , Francia , Enfermedad Aguda , Estudios Prospectivos , Factores de Tiempo , Adulto , Masculino , Femenino , Proyectos de Investigación , Pronóstico , Factores de Riesgo , Imagen por Resonancia Magnética , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven , Mortalidad Hospitalaria , Imagen por Resonancia Cinemagnética
9.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38532517

RESUMEN

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38316377

RESUMEN

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Anciano de 80 o más Años , Resultado del Tratamiento , Ajuste de Prótesis
12.
Ann Intensive Care ; 14(1): 21, 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38305979

RESUMEN

BACKGROUND: The benefit-risk balance and optimal timing of surgery for severe infective endocarditis (IE) with ischemic or hemorrhagic strokes is unknown. The study aim was to compare the neurological outcome between patients receiving surgery or not. METHODS: In a prospective register-based multicenter ICU study, patients were included if they met the following criteria: (i) left-sided IE with an indication for heart surgery; (ii) with cerebral complications documented by cerebral imaging before cardiac surgery; (iii) with Sequential Organ Failure Assessment score ≥ 3. Exclusion criteria were isolated right-sided IE, in-hospital acquired IE and patients with cerebral complications only after cardiac surgery. In the primary analysis, the prognostic value of surgery in term of disability at 6 month was assessed by using a propensity score-adjusted logistic regression. RESULTS: 192 patients were included including ischemic stroke (74.5%) and hemorrhagic lesion (15.6%): 67 (35%) had medical treatment and 125 (65%) cardiac surgery. In the propensity score-adjusted logistic regression, a favorable 6-month neurological outcome was associated with surgery (odds ratio 13.8 (95% CI 6.2-33.7). The 1-year mortality was strongly reduced with surgery in the fixed-effect propensity-adjusted Cox model (hazard ratio 0.18; 95% CI 0.11-0.27; p < 0.001). These effects remained whether the patients received delayed surgery (n = 62/125) or not and whether they were deeply comatose (Glasgow Coma Scale ≤ 10) or not. CONCLUSIONS: In critically ill IE patients with an indication for surgery and previous cerebral events, a better propensity-adjusted neurological outcome was associated with surgery compared with medical treatment.

13.
Echocardiography ; 41(1): e15728, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38113338

RESUMEN

INTRODUCTION: An arteriovenous fistula (AVF) in patients with end-stage kidney disease (ESKD) can influence flow states. We sought to evaluate if assessment of aortic stenosis (AS) by transthoracic echocardiographic (TTE) differs in the presence of AVF compared to other dialysis accesses in patients on dialysis. METHODS: We identified consecutive ESKD patients on dialysis and concomitant AS from a single center between January 2000 and March 2021. We analyzed TTE parameters of AS severity (velocities, gradients, aortic valve area [AVA]) and hemodynamics (cardiac output [CO], valvuloarterial impedance [Zva]) and compared AS parameters in patients with AVF versus other dialysis access. RESULTS: The cohort included 94 patients with co-prevalent ESKD and AS; mean age 66 years, 71% male; 43% Black, 24% severe AS. Dialysis access: 53% AVF, 47% others. In the overall cohort, no significant differences were noted between AVF versus non-AVF in AVA/CO/Zva, but with notable subgroup differences. In mild AS, CO was significantly higher in AVF versus non-AVF (6.3 vs. 5.2 L/min; p = .04). In severe AS, Zva was higher in the AVF versus non-AVF (4.6 vs. 3.6 mm Hg/mL/m2 ). With increasing AS severity in the AVF group, CO decreased, coupled with increase in Zva, likely counterbalancing the net hemodynamic impact of the AVF. CONCLUSION: Among ESKD patients with AS, TTE parameters of flow states and AS severity differed in those with AVF versus other dialysis accesses and varied with progression in severity of AS. Future longitudinal assessment of hemodynamic parameters in a larger cohort of co-prevalent ESRD and AS would be valuable.


Asunto(s)
Estenosis de la Válvula Aórtica , Derivación Arteriovenosa Quirúrgica , Fallo Renal Crónico , Humanos , Masculino , Anciano , Femenino , Diálisis Renal , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/terapia , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Hemodinámica
14.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38000627

RESUMEN

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

15.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37874020

RESUMEN

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estudios de Seguimiento , Readmisión del Paciente , Insuficiencia Cardíaca/etiología
16.
Cureus ; 15(9): e45648, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37868418

RESUMEN

A 75-year-old female patient was referred to our institution for severe symptomatic low-flow low-gradient aortic valve stenosis and tricuspid valve regurgitation (TR) associated with heart failure. After multidisciplinary discussion, the patient was scheduled for one-stage totally percutaneous treatment of her valve lesions by transcatheter aortic valve implantation (TAVI) and transcatheter edge-to-edge tricuspid valve repair (TEER) through transfemoral access. The patient had an uneventful hospital stay and was discharged home on the third postoperative day. During the following 24 months, the patient did well with regression of her heart failure signs and symptoms.

17.
Cureus ; 15(9): e45848, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37881383

RESUMEN

Tricuspid regurgitation is a frequent condition that is linked to an elevated risk of cardiovascular events and significant mortality but is often overshadowed by left-sided valve diseases. Isolated surgical tricuspid valve surgery is still considered a high-risk surgery, and over recent years, various transcatheter procedures for tricuspid treatment have emerged as an alternative solution. Among the available transcatheter procedures, the EVOQUE system's transcatheter tricuspid valve replacement could potentially offer a solution, especially in patients considered non-eligible for transcatheter edge-to-edge tricuspid valve repair. We present a case report of an octogenarian patient considered at prohibitive risk for conventional surgery and not eligible for transcatheter edge-to-edge repair who was eventually treated with a transfemoral transcatheter tricuspid 52-mm EVOQUE valve implantation. Postprocedural recovery and follow-up at 18 months were uneventful, with a well-functioning tricuspid valve bioprosthesis.

18.
Am J Cardiol ; 206: 89-97, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37690150

RESUMEN

Idiopathic dilated cardiomyopathy (IDCM) is one of the most common forms of nonischemic cardiomyopathy worldwide, possibly leading to cardiogenic shock (CS). Despite this heavy burden, the outcomes of CS in IDCM are poorly reported. Based on a large registry of unselected CS, our aim was to shed light on the 1-year outcomes after CS in patients with and without IDCM. FRENSHOCK was a prospective registry including 772 patients with CS from 49 centers. The 1-year outcomes (rehospitalizations, mortality, heart transplantation [HTx], ventricular assist devices [VAD]) were analyzed and adjusted on independent predictive factors. Within 772 CS included, 78 occurred in IDCM (10.1%). Patients with IDCM had more frequent history of chronic kidney failure and implantable cardioverter-defibrillator implantation. No difference was found in 1-month all-cause mortality between groups (28.2 vs 25.8%for IDCM and others, respectively; adjusted hazard ratio 1.14 [0.73 to 1.77], p = 0.57). Patients without IDCM were more frequently treated with noninvasive ventilation and intra-aortic balloon pump. At 1 year, IDCM led to higher rates of death or cardiovascular rehospitalizations (adjusted odds ratio 4.77 [95% confidence interval 1.13 to 20.1], p = 0.03) and higher rates of HTx or VAD for patients aged <65 years (adjusted odds ratio 2.68 [1.21 to 5.91], p = 0.02). In conclusion, CS in IDCM is a very common scenario and is associated with a higher rate of 1-year death or cardiovascular rehospitalizations and a more frequent recourse to HTx or VAD for patients aged <65 years, encouraging the consideration of it as a red flag for myocardial decline and urging for a closer follow-up and earlier evaluation for advanced heart failure therapies.

19.
Ann Thorac Surg ; 2023 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-37717882

RESUMEN

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

20.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37758382

RESUMEN

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Función Ventricular Izquierda , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA