Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Radiology ; 289(1): 238-247, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30040057

RESUMEN

Purpose To compare lesion primary patency and restenosis rates between drug-eluting balloon (DEB) percutaneous transluminal angioplasty (PTA) and conventional balloon PTA (cPTA) in the treatment of arteriovenous fistula (AVF) and arteriovenous graft (AVG) stenosis. Materials and Methods In this prospective study, 119 participants (mean age, 59.2 years; 79 men, 40 women) with failing AVFs (n = 98) or AVGs (n = 21) were randomly assigned to undergo either DEB PTA (n = 59) or cPTA (n = 60) from January 2012 to May 2013. Primary end points were lesion primary patency and restenosis rates at 6 months; secondary outcomes were anatomic and clinical success after PTA, circuit primary patency at 6 months and 1 year, and lesion primary patency at 1 year. Statistical analysis was performed by using the Kaplan-Meier product limit estimator, and hazard ratio was calculated by using Cox proportional hazards regression. Complication rates were assessed in both groups. Results Estimated lesion primary patency in the DEB PTA and cPTA arms was 0.81 and 0.61, respectively, at 6 months (P = .03) and 0.51 and 0.34, respectively, at 1 year (P = .04). Estimated circuit primary patency in the DEB PTA and cPTA arms was 0.76 and 0.56, respectively, at 6 months (P = .048) and 0.45 and 0.32, respectively, at 1 year (P = .16). Restenosis rate was 34.0% (16 of 47) for DEB PTA and 62.9% (22 of 35) for cPTA at 6 months (P = .01). No major complications were noted. Conclusion Drug-eluting balloon angioplasty was effective in prolonging lesion primary patency of dialysis access stenoses at 6 months and 1 year. © RSNA, 2018.


Asunto(s)
Angioplastia , Fístula Arteriovenosa/cirugía , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/cirugía , Anciano , Angioplastia/efectos adversos , Angioplastia/métodos , Angioplastia/estadística & datos numéricos , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/métodos , Angioplastia de Balón/estadística & datos numéricos , Fístula Arteriovenosa/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/estadística & datos numéricos , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diálisis Renal , Grado de Desobstrucción Vascular
2.
J Vasc Interv Radiol ; 23(10): 1294-301, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22922039

RESUMEN

PURPOSE: To evaluate the feasibility and safety of yttrium-90 ((90)Y) radioembolization through the inferior phrenic arteries (IPAs). MATERIALS AND METHODS: Retrospective analysis of 108 patients referred for radioembolization to treat primary (n = 103) or secondary (n = 5) liver malignancy was performed. Five patients had malignant hepatic tumors supplied by the IPA and met criteria for infusion of (90)Y spheres into the IPA. Digital subtraction angiography (DSA), catheter-directed computed tomographic (CT) angiography, and technetium-99m ((99m)Tc) macroaggregated albumin (MAA) single photon emission CT (SPECT)/CT were used to plan treatment. Bremsstrahlung SPECT/CT was performed 1 day after radioembolization. Follow-up included clinical and biochemical tests and cross-sectional CT or magnetic resonance imaging. RESULTS: Parasitized extrahepatic arteries were detected in 37% of patients (n = 40). Of these, 62.5% (n = 25) had tumor supply through an IPA. Of the patients with IPA supply, 20% (n = 5) underwent infusion of (90)Y into the right IPA. Reasons for disqualifying patients from infusion into the IPA were less than 10% tumor supply (n = 11), failed catheterization of IPA (n = 3), arterioportovenous shunt (n = 2), failed identification of IPA on pretreatment angiography (n = 1), and gastric or esophageal enhancement on catheter-directed CT angiography (n = 3). In all five patients, technical success was demonstrated on (90)Y imaging, with no significant extrahepatic radionuclide activity. No adverse events related to IPA radioembolization occurred at mean follow-up of 4.5 months (range, 2.2-10.1 mo). CONCLUSIONS: Delivery of (90)Y microspheres through the right IPA is feasible and safe with the use of catheter-directed CT angiography in addition to DSA and (99m)Tc MAA SPECT/CT in patients with tumors with greater than 10% IPA supply.


Asunto(s)
Carcinoma Hepatocelular/radioterapia , Embolización Terapéutica/métodos , Neoplasias Hepáticas/radioterapia , Radiofármacos/administración & dosificación , Radioisótopos de Itrio/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/diagnóstico , Embolización Terapéutica/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Infusiones Intraarteriales , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico , Imagen por Resonancia Magnética , Masculino , Microesferas , Persona de Mediana Edad , Imagen Multimodal , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Radiografía Intervencional , Radiofármacos/efectos adversos , Estudios Retrospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Radioisótopos de Itrio/efectos adversos
3.
Ann Nucl Med ; 25(9): 669-76, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21766243

RESUMEN

During pre-therapy evaluation for yttrium-90 (Y-90) radioembolization, it is uncommon to find severe imaging discordance between hepatic angiography versus technetium-99m-macroaggregated albumin (Tc-99m-MAA) single photon emission computed tomography with integrated low-dose CT (SPECT/CT). The reasons for severe imaging discordance are unclear, and literature is scarce. We describe 3 patients with severe imaging discordance, whereby tumor angiographic contrast hypervascularity was markedly mismatched to the corresponding Tc-99m-MAA SPECT/CT, and its clinical impact. The incidence of severe imaging discordance at our institution was 4% (3 of 74 cases). We postulate that imaging discordance could be due to a combination of 3 factors: (1) different injection rates between soluble contrast molecules versus Tc-99m-MAA; (2) different arterial flow hemodynamics between soluble contrast molecules versus Tc-99m-MAA; (3) eccentric release position of Tc-99m-MAA due to microcatheter tip location, inadvertently selecting non-target microparticle trajectories. Tc-99m-MAA SPECT/CT more accurately represents hepatic microparticle biodistribution than soluble contrast hepatic angiography and should be a key criterion in patient selection for Y-90 radioembolization. Tc-99m-MAA SPECT/CT provides more information than planar scintigraphy to guide radiation planning and clinical decision making. Severe imaging discordance at pre-therapy evaluation is ominous and should be followed up by changes to the final vascular approach during Y-90 radioembolization.


Asunto(s)
Angiografía/métodos , Hígado/diagnóstico por imagen , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada por Rayos X , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/fisiopatología , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/fisiopatología , Masculino , Persona de Mediana Edad
4.
J Vasc Interv Radiol ; 21(5): 657-62, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20430295

RESUMEN

PURPOSE: To assess the efficacy of endovenous laser therapy (EVLT) in the treatment of lower-limb venous ulcers secondary to venous reflux. MATERIALS AND METHODS: Forty-four of 139 patients referred for EVLT from January 2004 to August 2007 had nonhealing venous ulcers. Preprocedural duplex ultrasound (US) was performed to document saphenous venous reflux secondary to saphenofemoral/saphenopopliteal junction incompetence, deep venous insufficiency, and deep vein thrombosis. Follow-up intervals were within 1 week, monthly until ulcer healing, and every 6 months thereafter. Mean follow-up period was 35.8 months (range, 8.1-59.3 months). RESULTS: Mean great saphenous vein (GSV) diameter and length treated were 9.9 mm (range, 5.5-16.0 mm) and 36.7 cm (range, 20.0-60.0 cm). Mean laser energy used was 3,292 J (range, 1,392-4,971 J). Mean energy deposited per centimeter of vein was 93.6 J/cm (range, 45.2-182.0 J/cm). Mean laser time was 232 seconds (range, 99-347 sec). Fifteen patients with follow-up duplex US had no GSV flow at 6 months, with nonvisualization indicating complete obliteration. Ulcer healing occurred as early as 1 week after the procedure in some patients. Cumulative healing rates at 1, 3, 6, and 12 months were 82.1%, 92.5%, 92.5%, and 97.4%, respectively. No ulcer had recurred at 1 year, but ulcers recurred in five patients at 14, 14, 23, 35, and 52 months after EVLT, respectively. One patient with a nonhealing ulcer 2 years after treatment developed well differentiated squamous cell carcinoma. CONCLUSIONS: Ulcer epithelization occurred with continued GSV occlusion and loss of flow. Most ulcers healed within 3 months with no recurrence at 1 year. Nonhealing ulcers should undergo biopsy to exclude malignant transformation.


Asunto(s)
Terapia por Láser/métodos , Vena Safena/cirugía , Úlcera Varicosa/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA