Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39190066

RESUMEN

PURPOSE: To determine the relation between pelvic symmetry, as measured by the cross-measurement technique, and patient-reported outcome measures (PROMs) in terms of functional status and health-related quality of life. METHODS: In this prospective cohort study, X and Y measurements were taken according to the cross-measurement technique on AP radiographs of patients who were treated for an unstable pelvic ring injury in a level-1 trauma center. Patients completed PROMs at the time of admission (recalled pre-injury score) and one year following their injury, reporting their functional status with the Short Musculoskeletal Function Assessment (SMFA-NL), specifically the lower extremity dysfunction (LED), problems with daily activities (PDA) and mental and emotional problems (MEP) subscales, and quality of life with EuroQol-5D (EQ-5D). Subgroup analyses were also performed. PROMs were used to analyze the relation between pelvic symmetry and patient-reported outcome, using Spearman's Rank correlation coefficients. RESULTS: A total of 130 patients (mean age 58 (SD18) years) with an unstable pelvic ring injury were included, of which 95 (73%) sustained type-B injuries and 35 (27%) type-C injuries. Sixty-three (49%) patients were treated operatively. The median pelvic symmetry ratio was 1.01 (IQR: 0.05). Weak or no correlations were found between the pelvic symmetry scores and the outcome measurements (Spearman's correlation coefficients: LED r = 0.09; PDA r = 0.11; MEP r=-0.02; and EQ-5D r=-0.08). Subgroup analyses revealed no correlations. CONCLUSIONS: No significant relation was found between pelvic symmetry, measured radiologically, and functional status and health-related quality of life, one year following an unstable pelvic ring injury.

2.
Bone Joint J ; 106-B(9): 1008-1014, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39216867

RESUMEN

Aims: Paediatric triplane fractures and adult trimalleolar ankle fractures both arise from a supination external rotation injury. By relating the experience of adult to paediatric fractures, clarification has been sought on the sequence of injury, ligament involvement, and fracture pattern of triplane fractures. This study explores the similarities between triplane and trimalleolar fractures for each stage of the Lauge-Hansen classification, with the aim of aiding reduction and fixation techniques. Methods: Imaging data of 83 paediatric patients with triplane fractures and 100 adult patients with trimalleolar fractures were collected, and their fracture morphology was compared using fracture maps. Visual fracture maps were assessed, classified, and compared with each other, to establish the progression of injury according to the Lauge-Hansen classification. Results: Four stages of injury in triplane fractures, resembling the adult supination external rotation Lauge-Hansen stages, were observed. Stage I consists of rupture of the anterior syndesmosis or small avulsion of the anterolateral tibia in trimalleolar fractures, and the avulsion of a larger Tillaux fragment in triplanes. Stage II is defined as oblique fracturing of the fibula at the level of the syndesmosis, present in all trimalleolar fractures and in 30% (25/83) of triplane fractures. Stage III is the fracturing of the posterior malleolus. In trimalleolar fractures, the different Haraguchi types can be discerned. In triplane fractures, the delineation of the posterior fragment has a wave-like shape, which is part of the characteristic Y-pattern of triplane fractures, originating from the Tillaux fragment. Stage IV represents a fracture of the medial malleolus, which is highly variable in both the trimalleolar and triplane fractures. Conclusion: The paediatric triplane and adult trimalleolar fractures share common features according to the Lauge-Hansen classification. This highlights that the adolescent injury arises from a combination of ligament traction and a growth plate in the process of closing. With this knowledge, a specific sequence of reduction and optimal screw positions are recommended.


Asunto(s)
Fracturas de Tobillo , Humanos , Fracturas de Tobillo/diagnóstico por imagen , Niño , Adulto , Adolescente , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto Joven , Preescolar , Fijación Interna de Fracturas/métodos , Anciano de 80 o más Años , Estudios Retrospectivos
3.
Eur J Trauma Emerg Surg ; 50(1): 37-47, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38261077

RESUMEN

PURPOSE: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. METHODS: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. RESULTS: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6-3.9°) for rotation, 1.4° (IQR: 0.6-2.9°) for dorsal angulation, 4.7° (IQR: 2.9-5.7°) for radial angulation, and 2.4 mm (IQR: 1.3-2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. CONCLUSION: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.


Asunto(s)
Fracturas Mal Unidas , Fracturas del Radio , Cirugía Asistida por Computador , Humanos , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Cirugía Asistida por Computador/métodos , Fracturas Mal Unidas/cirugía , Osteotomía/métodos
4.
Bone Jt Open ; 5(1): 46-52, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38240277

RESUMEN

Aims: Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods: A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results: A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion: The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort.

5.
Eur J Trauma Emerg Surg ; 50(1): 11-19, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37391531

RESUMEN

PURPOSE: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures. METHODS: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction. RESULTS: A total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5-5.1). CONCLUSION: This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.


Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Fijación Interna de Fracturas , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Tornillos Óseos , Placas Óseas , Impresión Tridimensional
6.
Bone Joint J ; 105-B(11): 1226-1232, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37909160

RESUMEN

Aims: Triplane ankle fractures are complex injuries typically occurring in children aged between 12 and 15 years. Classic teaching that closure of the physis dictates the overall fracture pattern, based on studies in the 1960s, has not been challenged. The aim of this paper is to analyze whether these injuries correlate with the advancing closure of the physis with age. Methods: A fracture mapping study was performed in 83 paediatric patients with a triplane ankle fracture treated in three trauma centres between January 2010 and June 2020. Patients aged younger than 18 years who had CT scans available were included. An independent Paediatric Orthopaedic Trauma Surgeon assessed all CT scans and classified the injuries as n-part triplane fractures. Qualitative analysis of the fracture pattern was performed using the modified Cole fracture mapping technique. The maps were assessed for both patterns and correlation with the closing of the physis until consensus was reached by a panel of six surgeons. Results: Fracture map grouped by age demonstrates that, regardless of age (even at the extremes of the spectrum), the fracture lines consolidate in a characteristic Y-pattern, and no shift with closure of the physis was observed. A second fracture map with two years added to female age also did not show a shift. The fracture map, grouped by both age and sex, shows a Y-pattern in all different groups. The fracture lines appear to occur between the anterior and posterior inferior tibiofibular ligaments, and the medially fused physis or deltoid ligament. Conclusion: This fracture mapping study reveals that triplane ankle fractures have a characteristic Y-pattern, and acknowledges the weakness created by the physis, however it also challenges classic teaching that the specific fracture pattern at the level of the joint of these injuries relies on advancing closure of the physis with age. Instead, this study observes the importance of ligament attachment in the fracture patterns of these injuries.


Asunto(s)
Fracturas de Tobillo , Traumatismos del Tobillo , Humanos , Niño , Femenino , Adolescente , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Tomografía Computarizada por Rayos X , Placa de Crecimiento , Fijación Interna de Fracturas/métodos , Traumatismos del Tobillo/cirugía
7.
Artículo en Inglés | MEDLINE | ID: mdl-37962595

RESUMEN

INTRODUCTION: Angioembolisation (AE) and/or pre-peritoneal pelvic packing (PPP) may be necessary for patients with complex pelvic fractures who are haemodynamically unstable. However, it remains unclear whether AE or PPP should be performed as an initial intervention and ongoing debates exist. This meta-analysis aimed to compare AE versus PPP in haemodynamically unstable patients with acute pelvic fractures. The primary outcomes of interest were to compare in-hospital mortality rate and number of blood units transfused. Secondary outcomes included evaluating differences in the time from diagnosis to treatment, as well as the length of stay in the intensive care unit (ICU) and hospital. METHODS: All clinically relevant studies comparing AE versus PPP in patients with complex pelvic fractures and haemodynamic instability were accessed. The 2020 PRISMA guidelines were followed. In September 2023, the following databases were accessed: PubMed, Web of Science, Google Scholar and Embase, without constraint. RESULTS: Data from 320 patients were collected (AE: 174; PPP: 146). The mean age on admission was 47.4 ± 7.2 years. The mean Injury Severity Score (ISS) on admission was 43.5 + 5.4 points. Baseline comparability was observed in ISS (P = 0.5, Table 3) and mean age (P = 0.7, Table 3). No difference was reported in mortality rate (P = 0.2) or rate of blood units transfused (P = 0.3). AE had a longer mean time to the procedure of 44.6 min compared to PPP (P = 0.04). The mean length of ICU and hospital stay were similar in both groups. CONCLUSION: Despite the longer mean time from admission to the procedure, no significant differences were found between AE and PPP in terms of in-hospital mortality, blood units transfused, or length of ICU, and hospital stay. These findings should be interpreted considering the limitations of the present study. High-quality comparative research is strongly warranted. LEVEL OF EVIDENCE: Level IV, meta-analysis.

8.
BMJ Open ; 13(11): e064802, 2023 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-37993156

RESUMEN

INTRODUCTION: Rotational malalignment occurs in up to 30% of cases after intramedullary nailing of tibial shaft fractures. The aim of this study is to assess the clinical feasibility of a newly introduced standardised intraoperative fluoroscopy protocol coined 'C-arm rotational view (CARV)' in order to reduce the risk of rotational malalignment during intramedullary nailing of tibial shaft fractures. The CARV includes predefined fluoroscopy landmark views of the uninjured side to obtain correct alignment of the injured side with use of the rotation of the C-arm. METHODS AND ANALYSIS: This randomised controlled trial will be conducted in a level 1 trauma centre. Adult patients with an open or closed tibial fracture, eligible for intramedullary nailing, will be enrolled in the study. The interventional group will undergo intramedullary nailing guided by the CARV protocol to obtain accurate alignment. The control group is treated according to current clinical practice, in which alignment control of the tibia is based on clinical estimation of the treating surgeon. The primary endpoint is defined as the degree of rotation measured on low-dose postoperative CT scans. ETHICS AND DISSEMINATION: The study protocol will be performed in line with local ethical guidelines and the Declaration of Helsinki. The results of this trial will be disseminated in a peer-reviewed manuscript. Future patients are likely to benefit from this trial as it aims to provide a clinically feasible and easy-to-use standardised fluoroscopy protocol to reduce the risk for rotational malalignment during intramedullary nailing of tibial shaft fractures. TRIAL REGISTRATION NUMBER: NCT05459038.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de la Tibia , Adulto , Humanos , Estudios Prospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Tomografía Computarizada por Rayos X , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Clavos Ortopédicos , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
J Clin Med ; 12(18)2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37762994

RESUMEN

BACKGROUND: Conventional measures of fracture displacement have low interobserver reliability. This study introduced a novel 3D method to measure tibial plateau fracture displacement and its impact on functional outcome. METHODS: A multicentre study was conducted on patients who had tibial plateau fracture surgery between 2003 and 2018. Eligible patients had a preoperative CT scan (slice thickness ≤ 1 mm) and received a Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire. A total of 362 patients responded (57%), and assessment of initial and residual fracture displacement was performed via measurement using the 3D gap area (mm2). Patients were divided into four groups based on the 3D gap area size. Differences in functional outcome between these groups were assessed using analysis of variance (ANOVA). Multiple linear regression was used to determine the association between fracture displacement and patient-reported outcome. RESULTS: Functional outcome appeared significantly worse when initial or residual fracture displacement increased. Multivariate linear regression showed that initial 3D gap area (per 100 mm2) was significantly negatively associated with all KOOS subscales: symptoms (-0.9, p < 0.001), pain (-0.0, p < 0.001), ADL (-0.8, p = 0.002), sport (-1.4, p < 0.001), and QoL (-1.1, p < 0.001). In addition, residual gap area was significantly negatively associated with the subscales symptoms (-2.2, p = 0.011), ADL (-2.2, p = 0.014), sport (-2.6, p = 0.033), and QoL (-2.4, p = 0.023). CONCLUSION: A novel 3D measurement method was applied to quantify initial and residual displacement. This is the first study which can reliably classify the degree of displacement and indicates that increasing displacement results in poorer patient-reported functional outcomes.

10.
Bone Joint J ; 105-B(9): 1020-1029, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37652442

RESUMEN

Aims: The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. Methods: A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis. Results: Of 170 patients, 22 (13%) subsequently received a THA. Native hip survival in patients with a step-off ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 94% vs 70% vs 74%). Native hip survival in patients with a gap ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 100% vs 84% vs 78%). Step-off displacement > 2 mm (> 2 to 4 mm hazard ratio (HR) 4.9, > 4 mm HR 5.6) and age > 60 years (HR 2.9) were independent predictors for conversion to THA at follow-up. Conclusion: Patients with minimally displaced acetabular fractures who opt for nonoperative fracture treatment may be informed that fracture displacement (e.g. gap and step-off) up to 2 mm, as measured on CT images, results in limited risk on conversion to THA. Step-off ≥ 2 mm and age > 60 years are predictors for conversion to THA and can be helpful in the shared decision-making process.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Persona de Mediana Edad , Estudios Transversales , Tomografía Computarizada por Rayos X
11.
J Clin Med ; 12(11)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37297962

RESUMEN

Knowledge about anatomical shape variations in the pelvis is mandatory for selection, fitting, positioning, and fixation in pelvic surgery. The current knowledge on pelvic shape variation mostly relies on point-to-point measurements on 2D X-ray images and computed tomography (CT) slices. Three-dimensional region-specific assessments of pelvic morphology are scarce. Our aim was to develop a statistical shape model of the hemipelvis to assess anatomical shape variations in the hemipelvis. CT scans of 200 patients (100 male and 100 female) were used to obtain segmentations. An iterative closest point algorithm was performed to register these 3D segmentations, so a principal component analysis (PCA) could be performed, and a statistical shape model (SSM) of the hemipelvis was developed. The first 15 principal components (PCs) described 90% of the total shape variation, and the reconstruction ability of this SSM resulted in a root mean square error of 1.58 (95% CI: 1.53-1.63) mm. In summary, an SSM of the hemipelvis was developed, which describes the shape variations in a Caucasian population and is able to reconstruct an aberrant hemipelvis. Principal component analyses demonstrated that, in a general population, anatomical shape variations were mostly related to differences in the size of the pelvis (e.g., PC1 describes 68% of the total shape variation, which is attributed to size). Differences between the male and female pelvis were most pronounced in the iliac wing and pubic rami regions. These regions are often subject to injuries. Future clinical applications of our newly developed SSM may be relevant for SSM-based semi-automatic virtual reconstruction of a fractured hemipelvis as part of preoperative planning. Lastly, for companies, using our SSM might be interesting in order to assess which sizes of pelvic implants should be produced to provide proper-fitting implants for most of the population.

12.
Diagnostics (Basel) ; 13(9)2023 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-37175020

RESUMEN

Displacement of the anterior and posterior column complicates decision making for both-column acetabular fractures. We questioned whether pelvic surgeons agree on treatment strategy, and whether the use of virtual 3D reconstructions changes the treatment strategy of choice. A nationwide cross-sectional survey was performed in all pelvic trauma centers in the Netherlands. Twenty surgeons assessed 15 both-column fractures in 2D as well as 3D. Based on conventional imaging, surgical treatment was recommended in 89% of cases, and by adding 3D reconstructions this was 93% (p = 0.09). Surgical approach was recommended as anterior (65%), posterior (8%) or combined (27%) (poor level of agreement, κ = 0.05) based on conventional imaging. The approach changed in 37% (p = 0.006), with most changes between a combined and anterior approach (still poor level of agreement, κ = 0.13) by adding 3D reconstructions. Additionally, surgeons' level of confidence increased from good in 38% to good in 50% of cases. In conclusion, surgeons do not agree on the treatment strategy for both-column acetabular fractures. Additional information given by 3D reconstructions may change the chosen surgical approach and increase surgeons' confidence about their treatment decision. Therefore, virtual 3D reconstructions are helpful for assessing both-column fracture patterns and aid in the choice of treatment strategy.

14.
J Pers Med ; 12(9)2022 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-36143242

RESUMEN

Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique. Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation. Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively. Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate.

15.
J Pers Med ; 12(9)2022 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-36143248

RESUMEN

This study aims to develop a three-dimensional (3D) measurement for acetabular fracture displacement, determine the inter- and intra-observer variability, and correlate the measurement with clinical outcome. Three-dimensional models were created for 100 patients surgically treated for acetabular fractures. The '3D gap area', the 3D surface between all the fracture fragments, was developed. The association between the 3D gap area and the risk of conversion to a total hip arthroplasty (THA) was determined by an ROC curve and a Cox regression analysis. The 3D gap area had an excellent inter-observer and intra-observer reliability. The preoperative median 3D gap area for patients without and with a THA was 1731 mm2 versus 2237 mm2. The median postoperative 3D gap area was 640 mm2 versus 845 mm2. The area under the curve was 0.63. The Cox regression analysis showed that a preoperative 3D gap area > 2103 mm2 and a postoperative 3D gap area > 1058 mm2 were independently associated with a 3.0 versus 2.4 times higher risk of conversion to a THA. A 3D assessment of acetabular fractures is feasible, reproducible, and correlates with clinical outcome. Three-dimensional measurements could be added to the current classification systems to quantify the level of fracture displacement and to assess operative results.

16.
PLoS One ; 17(9): e0275206, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36166437

RESUMEN

INTRODUCTION: Gap and step-off measurements are generally used in the surgical decision-making process of distal radius fractures. Unfortunately, there is no consensus on treatment choice as these measurements are prone to inter- and intraobserver variability. In this study, we aim to introduce a new 3D fracture quantification method and compare it to conventional fracture analysis. METHODS: Forty patients with a minimally displaced intra-articular distal radius fracture that was treated nonoperatively between 2008-2015 were included. 2D-CT images were reassessed by three orthopedic trauma surgeons who performed gap and step-off measurements. Subsequently, 3D models were created and a 3D measurement method for fracture displacement was developed. For each fracture, the '3D gap area' (3D surface between all fracture fragments) was determined by three observers. Interobserver agreements were calculated for all measurements, and the intraobserver agreement was calculated for the new 3D measurement. All patients completed two questionnaires in order to link our measurements to functional outcome. RESULTS: The interobserver agreement of the 2D measurements was fair (ICC = 0.54) for the gap and poor (ICC = 0.21) for the step-off. The median gap was 2.8 (IQR: 1.9-3.5) mm and step-off was 0.9 (IQR: 0.0-1.6) mm. Interobserver agreement on 3D gap area measurements was excellent (ICC = 0.81), with a median difference between measurements of 6.0 (IQR: 2.0-19.0) mm2, which indicates reliable assessment of 3D fracture displacement. Intraobserver agreement was also excellent (ICC = 0.98), with a median difference of 4.0 (IQR: 1.5-5.5) mm2. No significant differences in clinical outcome were found between the above and below 2mm displacement groups. The score of the DASH was 3.4 (IQR: 0.4-8.8) versus 4.2 (IQR: 0.0-11.6) respectively. Results from the PRWE questionnaire shows a similar result of 3.5 (IQR: 0.0-12.6) versus 5.0 (IQR: 0.0-25.5). CONCLUSION: 3D gap area is a more objective measurement method compared to the conventional gap and step-off measurements to quantify the level of fracture displacement of distal radius fractures. 3D fracture assessment can be used in addition to the currently used classification systems of distal radius fractures.


Asunto(s)
Cirujanos Ortopédicos , Fracturas del Radio , Humanos , Variaciones Dependientes del Observador , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
17.
Artículo en Inglés | MEDLINE | ID: mdl-35907028

RESUMEN

PURPOSE: Rotational malalignment (≥ 10°) is a frequent pitfall of intramedullary-nailing of tibial shaft fractures. This study aimed to develop an intraoperative fluoroscopy protocol, coined 'C-Arm Rotational View (CARV)', to significantly reduce the risk for rotational malalignment and to test its clinical feasibility. METHODS: A cadaver and clinical feasibility study was conducted to develop the CARV-technique, that included a standardized intraoperative fluoroscopy sequence of predefined landmarks on the uninjured and injured leg in which the rotation of the C-arm was used to verify for rotational alignment. A mid-shaft tibia fracture was simulated in a cadaver and an unlocked intramedullary-nail was inserted. Random degrees of rotational malalignment were applied using a hand-held goniometer via reference wires at the fracture site. Ten surgeons, blinded for the applied rotation, performed rotational corrections according to (1) current clinical practice after single-leg and dual-leg draping, and (2) according to the CARV-protocol. The primary outcome measure was the accuracy of the corrections relative to neutral tibial alignment. The CARV-protocol was tested in a small clinical cohort. RESULTS: In total, 180 rotational corrections were performed by 10 surgeons. Correction according to clinical practice using single-leg and dual-leg draping resulted in a median difference of, respectively, 10.0° (IQR 5.0°) and 10.0° (IQR 5.0°) relative to neutral alignment. Single-leg and dual-leg draping resulted in malalignment (≥10°) in, respectively, 67% and 58% of the corrections. Standardized correction using the CARV resulted in a median difference of 5.0° (IQR 5.0°) relative to neutral alignment, with only 12% categorized as malalignment (≥10°). The incidence of rotational malalignment after application of the CARV decreased from 67% and 58% to 12% (p = <0.001). Both consultants and residents successfully applied the CARV-protocol. Finally, three clinical patients with a tibial shaft fracture were treated according to the CARV-protocol, resulting all in acceptable alignment (<10°) based on postoperative CT-measurements. CONCLUSION: This study introduces an easy-to-use and clinically feasible standardized intraoperative fluoroscopy protocol coined 'C-arm rotational view (CARV)' to minimize the risk for rotational malalignment following intramedullary-nailing of tibial shaft fractures.

18.
Eur J Trauma Emerg Surg ; 48(4): 2849-2857, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35254459

RESUMEN

PURPOSE: Pelvic ring injuries are known to affect the patients' daily life in terms of physical functioning and quality of life (QoL). Still, prospective studies on the patient's perception over the first 2 years of rehabilitation are lacking. Therefore, patients cannot be properly informed about whether or when they will return to their pre-existing level of physical functioning and QoL. METHODS: A prospective longitudinal cohort study was performed over a 4-year period including all consecutive patients above 18 years who sustained a pelvic ring injury in a level 1 trauma center. Validated patient-reported outcome measures (PROMs) were used to assess physical functioning (SMFA) and QoL (EQ-5D) at baseline (recalled pre-injury score), 6 weeks, 3 months, 6 months, 1 year and 2 years after the injury. It was assessed whether patients had fully recovered by comparing follow-up scores to baseline PROMs. Binary logistic regression analysis was used to identify independent predictors for patients who did not fully recover. Most experienced difficulties at 3 months and 1 year were identified by analyzing the highest reported scores on individual items of the SMFA. RESULTS: A total of 297 patients with a pelvic ring injury were identified of which 189 were eligible for follow-up and 154 (82%) responded. Median SMFA function score at 3 months, 1 and 2 years was 70, 78 and 88, respectively, compared to 96 out of 100 before the injury. Median SMFA bother score was 67, 79 and 88, respectively. Median EQ-5D score at 3 months, 1 and 2 years was 0.61, 0.81 and 0.85, respectively, compared to 1 (maximum achievable) before the injury. After 1 and 2 years of follow-up, 61% and 75% of the patients fully "recovered" in physical functioning and 52% and 71% fully recovered in terms of QoL. Female gender and high-energy trauma were independent predictors for not fully recovering after 1 year. After 3 months of follow-up, 54% of patients reported severe difficulties with recreational activities, whereas after 1 year, most experienced difficulties (31% of patients) concerned heavy house or yard work. Moreover, after 3 months and 1 year, 44% and 27% of patients reported feeling physically disabled. CONCLUSION: Pelvic ring injuries have a large impact on the patients' daily life in the first 2 years of rehabilitation. Directly after the injury, physical functioning and QoL decrease strongly but then gradually improve over a 2-year period with about 75% of patients fully recovering. Female gender and high-energy trauma are shown to be independent predictors for not fully recovering. After 3 months, patients experience difficulties with both the physical and mental effects of the injury which continue to be present after 1 year.


Asunto(s)
Huesos Pélvicos , Calidad de Vida , Femenino , Humanos , Estudios Longitudinales , Salud Mental , Huesos Pélvicos/lesiones , Estudios Prospectivos
19.
Eur J Trauma Emerg Surg ; 48(3): 1737-1749, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34463771

RESUMEN

PURPOSE: The aim of this systematic review was to provide an overview of current applications of 3D technologies in surgical management of tibial plateau fractures and to assess whether 3D-assisted surgery results in improved clinical outcome as compared to surgery based on conventional imaging modalities. METHODS: A literature search was performed in Pubmed and Embase for articles reporting on the use of 3D techniques in operative management of tibial plateau fractures. This systematic review was performed in concordance with the PRISMA-guidelines. Methodological quality and risk of bias was assessed according to the guidelines of the McMaster Critical Appraisal. Differences in terms of operation time, blood loss, fluoroscopy frequency, intra-operative revision rates and patient-reported outcomes between 3D-assisted and conventional surgery were assessed. Data were pooled using the inverse variance weighting method in RevMan. RESULTS: Twenty articles evaluating 948 patients treated with 3D-assisted surgery and 126 patients with conventional surgery were included. Five different concepts of 3D-assisted surgery were identified: '3D virtual visualization', '3D printed hand-held fracture models', 'Pre-contouring of osteosynthesis plates', '3D printed surgical guides', and 'Intra-operative 3D imaging'. 3D-assisted surgery resulted in reduced operation time (104.7 vs. 126.4 min; P < 0.01), less blood loss (241 ml vs. 306 ml; P < 0.01), decreased frequency of fluoroscopy (5.8 vs. 9.1 times; P < 0.01). No differences in functional outcome was found (Hospital for Special Surgery Knee-Rating Scale: 88.6 vs. 82.8; P = 0.23). CONCLUSIONS: Five concepts of 3D-assisted surgical management of tibial plateau fractures emerged over the last decade. These include 3D virtual fracture visualization, 3D-printed hand-held fracture models for surgical planning, 3D-printed models for pre-contouring of osteosynthesis plates, 3D-printed surgical guides, and intra-operative 3D imaging. 3D-assisted surgery may have a positive effect on operation time, blood loss, and fluoroscopy frequency.


Asunto(s)
Impresión Tridimensional , Fracturas de la Tibia , Placas Óseas , Fijación Interna de Fracturas/métodos , Humanos , Tempo Operativo , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
20.
J Clin Med ; 10(21)2021 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-34768394

RESUMEN

The purpose of this study was to evaluate the prevalence of sarcopenia and/or myosteatosis in elderly patients with pelvic ring injuries and their influence on mortality, patient-perceived physical functioning and quality of life (QoL). A multicenter retrospective cohort study was conducted including elderly patients aged ≥ 65 treated for a pelvic ring injury. Cross-sectional computed tomography (CT) muscle measurements were obtained to determine the presence of sarcopenia and/or myosteatosis. Kaplan-Meier analysis was used for survival analysis, and Cox proportional hazards regression analysis was used to determine risk factors for mortality. Patient-reported outcome measures for physical functioning (SMFA) and QoL (EQ-5D) were used. Multivariable linear regression analyses were used to determine the effect of sarcopenia and myosteatosis on patient-perceived physical functioning and QoL. Data to determine sarcopenia and myosteatosis were available for 199 patients, with a mean follow-up of 2.4 ± 2.2 years: 66 patients (33%) were diagnosed with sarcopenia and 65 (32%) with myosteatosis, while 30 of them (15%) had both. Mortality rates in patients at 1 and 3 years without sarcopenia and myosteatosis were 13% and 21%, compared to 11% and 36% in patients with sarcopenia, 17% and 31% in patients with myosteatosis and 27% and 43% in patients with both. Higher age at the time of injury and a higher Charlson Comorbidity Index (CCI) were independent risk factors for mortality. Patient-reported mental and emotional problems were significantly increased in patients with sarcopenia.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA