Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Talanta ; 281: 126818, 2025 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-39277935

RESUMEN

This study introduces an innovative approach for quantifying isomeric pollutants utilizing an amperometric sensor. The determination of the isomers hydroquinone and catechol is based on the use of a glassy carbon electrode modified with Cu@PtPd/C nanoparticles (Cu@PtPd/C/GCE) in core-shell form, showing significant electrocatalytic activity in the oxidation of the later compounds. The determination was carried out at two different potentials: one at which where only hydroquinone is oxidized, and another in which where both hydroquinone and catechol are oxidized. Using these potentials, two calibration curves were built, one for the quantification of hydroquinone and the other for both isomers. Subsequently, the quantification of catechol was performed using a strategy based on the calculation of a difference using the information collected in the first step. The experiments using hydrogen peroxide as a redox probe demonstrate a clear synergistic effect in the catalytic reduction of hydrogen peroxide at -0.100 V, when Pt, Pd and Cu are incorporated into the core-shell nanostructure. The best performance was achieved with Cu@PtPd/C/GCE 1.00 mg mL-1. For the selected sensor, the analytical parameters are very competitive compared to similar devices reported in recent years for hydroquinone and catechol, with comparable linearity ranges of 0.010-0.200 mmol L-1 (hydroquinone) and 0.005-0.500 mmol L-1 (catechol), low limits of detection (LODs) of 14.0 nmol L-1 (S/N = 3.3) and 1.75 nmol L-1 (S/N = 3.3) for hydroquinone and catechol. The resulting sensor platform has been successfully applied for the quantification of hydroquinone and catechol in river and tap water and could be a promising candidate for environmental monitoring and drinking water safety.

2.
Environ Sci Pollut Res Int ; 31(10): 14845-14857, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38285256

RESUMEN

The global consumption of antibiotics leads to their possible occurrence in the environment. In this context, nature-based solutions (NBS) can be used to sustainably manage and restore natural and modified ecosystems. In this work, we studied the efficiency of the NBS free-water surface wetlands (FWSWs) using Eichhornia crassipes in microcosm for enrofloxacin removal. We also explored the behavior of enrofloxacin in the system, its accumulation and distribution in plant tissues, the detoxification mechanisms, and the possible effects on plant growth. Enrofloxacin was initially taken up by E. crassipes (first 100 h). Notably, it accumulated in the sediment at the end of the experimental time. Removal rates above 94% were obtained in systems with sediment and sediment + E. crassipes. In addition, enrofloxacin was found in leaves, petioles, and roots (8.8-23.6 µg, 11-78.3 µg, and 10.2-70.7 µg, respectively). Furthermore, enrofloxacin, the main degradation product (ciprofloxacin), and other degradation products were quantified in the tissues and chlorosis was observed on days 5 and 9. Finally, the degradation products of enrofloxacin were analyzed, and four possible metabolic pathways of enrofloxacin in E. crassipes were described.


Asunto(s)
Eichhornia , Contaminantes Químicos del Agua , Humedales , Ecosistema , Enrofloxacina , Contaminantes Químicos del Agua/análisis , Biodegradación Ambiental
3.
Anal Chim Acta ; 1209: 339342, 2022 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-35569842

RESUMEN

The present tutorial aims to review the most frequently reported criteria for the calculation of the limits of detection (LOD) and quantification (LOQ) in univariate calibration, summarizing their fundamentals, advantages, and limitations. The current criteria for estimating LOD and LOQ are based on diverse theoretical and/or empirical assumptions and require different amounts of experimental data, making the calculation rather complex in some cases. Moreover, alternative forms for calculating LOD/LOQ frequently lead to dissimilar results. This scenario might worsen in the case of complex analytical systems. Throughout this tutorial, different forms of calculating LOD/LOQ are illustrated using previously reported experimental datasets in the environmental chemistry field as examples. The influence of the sample matrix during the estimation of LOD/LOQ parameters is investigated through one calibration approache. The discrepancies in the obtained results with different criteria for the calculation of LOD/LOQ are highlighted. Finally, general guidelines and recommendations regarding experimental and data processing issues are proposed, aiming to promote fair criteria for the comparison of different analytical methodologies in terms of prediction ability and detection capability.


Asunto(s)
Proyectos de Investigación , Calibración , Límite de Detección
4.
Talanta ; 242: 123290, 2022 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-35151082

RESUMEN

This work reports for the first time the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multi-wall carboxylated carbon nanotubes (MWCNTs-COOH) using a mixture of a natural deep eutectic solvent (NADES - LGH/lactic acid-glucose-water), ethylene glycol (EG) and water (GCE/MWCNT-LGH-EG) for the determination and N-(4-hydroxyphenyl) acetamide (paracetamol) (APAP) in urine samples. The optimization of both dispersion and measurement conditions was carried out using experimental design. The modified electrode exhibited enhanced current responses, demonstrating excellent electrochemical response towards APAP oxidation compared to MWCNTs-LGH, MWCNTs-EG, MWCNTs-H2O-EtOH and MWCNTs-H2O. The linear dependence between the anodic peak currents and the square root of scan rates over the range of 0.010-0.300 Vs-1 demonstrates that the electro oxidation of APAP occurs under diffusional control. The MWCNT-LGH-EG modified GCE displayed an analytical sensitivity of 10.72 mL µg-1 (r = 0.9994) and a detection limit of 100 ng mL-1 for the selective determination of APAP in urine samples. The proposed electrochemical sensor was successfully applied for quantifying APAP in urine samples in the presence of uric acid. In addition, the accuracy and precision of the method was contrasted against a HPLC reference method.


Asunto(s)
Nanotubos de Carbono , Acetaminofén , Disolventes Eutécticos Profundos , Técnicas Electroquímicas/métodos , Electrodos , Límite de Detección , Solventes
5.
Environ Toxicol Chem ; 38(10): 2305-2313, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31291022

RESUMEN

The use of fluoroquinolones for the treatment of infections in humans and animals has increased in Argentina, and they can be found in large amounts in water bodies. The present study investigated the occurrence and associated ecological risk of 5 fluoroquinolones in rivers and farm wastewaters of San Luis, Santa Fe, Córdoba, Entre Ríos, and Buenos Aires provinces of Argentina by high-performance liquid chromatography coupled to fast-scanning fluorescence detection and ultra-high-performance liquid chromatography coupled to triple quadrupole mass spectrometry detection. The maximum concentrations of ciprofloxacin, enrofloxacin, ofloxacin, enoxacin, and difloxacin found in wastewater were 1.14, 11.9, 1.78, 22.1, and 14.2 µg L-1 , respectively. In the case of river samples, only enrofloxacin was found, at a concentration of 0.97 µg L-1 . The individual risk of aquatic organisms associated with water pollution due to fluoroquinolones was higher in bacteria, cyanobacteria, algae, plants, and anurans than in crustaceae and fish, with, in some cases, risk quotients >1. The proportion of samples classified as high risk was 87.5% for ofloxacin, 63.5% for enrofloxacin, 57.1% for ciprofloxacin, and 25% for enoxacin. Our results suggest that the prevalence of fluoroquinolones in water could be potentially risky for the aquatic ecosystem, and harmful to biodiversity. Environ Toxicol Chem 2019;38:2305-2313. © 2019 SETAC.


Asunto(s)
Ecosistema , Fluoroquinolonas/análisis , Medición de Riesgo , Ríos/química , Aguas Residuales/química , Animales , Argentina , Cromatografía Líquida de Alta Presión , Exposición a Riesgos Ambientales/análisis , Geografía , Humanos , Contaminantes Químicos del Agua/análisis
6.
Electrophoresis ; 38(8): 1122-1129, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28177131

RESUMEN

In the previously published part of this study, we detailed a novel strategy based on dispersive liquid-liquid microextraction to extract and preconcentrate nine fluoroquinolones in porcine blood. Moreover, we presented the optimized experimental conditions to obtain complete CE separation between target analytes. Consequently, this second part reports the validation of the developed method to determine flumenique, difloxacin, enrofloxacin, marbofloxacin, ofloxacin, ciprofloxacin, through univariate calibration, and enoxacin, danofloxacin, and gatifloxacin through multivariate curve resolution analysis. The validation was performed according to FDA guidelines for bioanalytical assay procedures and the European Directive 2002/657 to demonstrate that the results are reliable. The method was applied for the determination of fluoroquinolones in real samples. Results indicated a high selectivity and excellent precision characteristics, with RSD less than 11.9% in the concentrations, in intra- and interassay precision studies. Linearity was proved for a range from 4.00 to 30.00 mg/L and the recovery has been investigated at four different fortification levels, from 89 to 113%. Several approaches found in the literature were used to determinate the LODs and LOQs. Though all strategies used were appropriate, we obtained different values when using different methods. Estimating the S/N ratio with the mean noise level in the migration time of each fluoroquinolones turned out as the best studied method for evaluating the LODs and LOQs, and the values were in a range of 1.55 to 4.55 mg/L and 5.17 to 9.62 mg/L, respectively.


Asunto(s)
Electroforesis Capilar/métodos , Microextracción en Fase Líquida/métodos , Quinolonas/aislamiento & purificación , Animales , Calibración , Electroforesis Capilar/normas , Análisis de los Mínimos Cuadrados , Límite de Detección , Quinolonas/sangre , Valores de Referencia , Porcinos
7.
Environ Toxicol Pharmacol ; 51: 114-123, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28233700

RESUMEN

The ecological risks posed by two ß-diketone antibiotics (DKAs, enrofloxacin, ENR and ciprofloxacin, CPX), characterized by their long persistence in aqueous environments and known deleterious effect on model organisms such as zebrafish were analysed using Rhinella arenarum larvae. Sublethal tests were conducted using environmentally relevant concentrations of both ENR and CPX (1-1000µgL-1) under standard laboratory conditions for 96h. Biological endpoints and biomarkers evaluated were body size, shape, development and growth rates, and antioxidant enzymes (glutathione-S-transferase, GST; Catalase, CAT). Risk assessment was analysed based on ration quotients (RQ). The size and shape measurements of the larvae exposed to concentrations greater than 10µgL-1 of CPX were lower compared to controls (Dunnett post hoc p<0.05) and presented signs of emaciation. Concentrations of 1000µgL-1of CPX induced GST activity, in contrast with inhibited GST and CAT of larvae exposed to ENR. Risk assessments indicated that concentrations greater than or equal to10µgL-1 of CPX and ENR are ecotoxic for development, growth, detoxifying, and oxidative stress enzymes. It is suggested that additional risk assessments may provide evidence of bioaccumulation of CPX and ENR in tissues or organs of amphibian larvae by mesocosm sediment test conditions. Finally, intestinal microbiome studies should be considered to establish the mechanisms of action of both antibiotics.


Asunto(s)
Antibacterianos/toxicidad , Ciprofloxacina/toxicidad , Embrión no Mamífero/efectos de los fármacos , Fluoroquinolonas/toxicidad , Drogas Veterinarias/toxicidad , Contaminantes Químicos del Agua/toxicidad , Animales , Argentina , Bufonidae , Ecotoxicología , Embrión no Mamífero/metabolismo , Enrofloxacina , Monitoreo del Ambiente , Larva , Estrés Oxidativo/efectos de los fármacos , Pruebas de Toxicidad Aguda
8.
Electrophoresis ; 37(20): 2670-2677, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27377189

RESUMEN

A dispersive liquid-liquid microextraction procedure was developed to extract nine fluoroquinolones in porcine blood, six of which were quantified using a univariate calibration method. Extraction parameters including type and volume of extraction and dispersive solvent and pH, were optimized using a full factorial and a central composite designs. The optimum extraction parameters were a mixture of 250 µL dichloromethane (extract solvent) and 1250 µL ACN (dispersive solvent) in 500 µL of porcine blood reached to pH 6.80. After shaking and centrifugation, the upper phase was transferred in a glass tube and evaporated under N2 steam. The residue was resuspended into 50 µL of water-ACN (70:30, v/v) and determined by CE method with DAD, under optimum separation conditions. Consequently, a tenfold enrichment factor can potentially be reached with the pretreatment, taking into account the relationship between initial sample volume and final extract volume. Optimum separation conditions were as follows: BGE solution containing equal amounts of sodium borate (Na2 B4 O7 ) and di-sodium hydrogen phosphate (Na2 HPO4 ) with a final concentration of 23 mmol/L containing 0.2% of poly (diallyldimethylammonium chloride) and adjusted to pH 7.80. Separation was performed applying a negative potential of 25 kV, the cartridge was maintained at 25.0°C and the electropherograms were recorded at 275 nm during 4 min. The hydrodynamic injection was performed in the cathode by applying a pressure of 50 mbar for 10 s.


Asunto(s)
Electroforesis Capilar/métodos , Fluoroquinolonas/sangre , Fluoroquinolonas/aislamiento & purificación , Microextracción en Fase Líquida/métodos , Animales , Residuos de Medicamentos/análisis , Residuos de Medicamentos/aislamiento & purificación , Porcinos , Drogas Veterinarias/sangre , Drogas Veterinarias/aislamiento & purificación
9.
Chemosphere ; 135: 24-30, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25880706

RESUMEN

Retinoids are known to regulate important processes such as differentiation, development, and embryogenesis of vertebrates: Alteration in endogenous retinoids concentration is linked with teratogenic effects. Retinol (ROH), retinoid acid (RA), and isoform 13-Cis-retinoic acid (13-Cis-RA), in plasma of a native adults frog, Leptodactylus chaquensis from a rice field (RF) and a forest (reference site; RS) were measured. ROH did not vary between treatment sites. RA and 13-Cis-RA activities were higher (93.7±8.6 µg mL(-1) and 131.7±11.4 µg mL(-1), respectively) in individuals collected from RF than in those from RS (65.5±8.6 µg mL(-1) and 92.2±10.2 µg mL(-1), respectively). The ratios retinoic acid-retinol (RA/ROH) and 13-Cis-RA/ROH revealed significantly higher values in RF than in RS. RA and 13-Cis-RA concentrations in plasma on wild amphibian's species such as L. chaquensis would be suitable biomarkers of pesticide exposure in field monitoring. Finally, the mechanism of alteration in retinoid metabolites alteration should be further explored both in larvae and adult, considering that the potential exposition and uptake contaminants vary between the double lives of these vertebrates.


Asunto(s)
Anuros/sangre , Monitoreo del Ambiente , Oryza , Ranidae/sangre , Retinoides/sangre , Adulto , Agricultura , Animales , Argentina , Ecosistema , Humanos , Larva , Tretinoina
10.
J Pharm Anal ; 5(5): 296-306, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29403943

RESUMEN

An efficient generic static headspace gas chromatography (HSGC) method was developed, optimized and validated for the routine determination of several residual solvents (RS) in drug substance, using a strategy with two sets of calibration. Dimethylsulfoxide (DMSO) was selected as the sample diluent and internal standards were used to minimize signal variations due to the preparative step. A gas chromatograph from Agilent Model 6890 equipped with flame ionization detector (FID) and a DB-624 (30 m×0.53 mm i.d., 3.00 µm film thickness) column was used. The inlet split ratio was 5:1. The influencing factors in the chromatographic separation of the analytes were determined through a fractional factorial experimental design. Significant variables: the initial temperature (IT), the final temperature (FT) of the oven and the carrier gas flow rate (F) were optimized using a central composite design. Response transformation and desirability function were applied to find out the optimal combination of the chromatographic variables to achieve an adequate resolution of the analytes and short analysis time. These conditions were 30 °C for IT, 158 °C for FT and 1.90 mL/min for F. The method was proven to be accurate, linear in a wide range and very sensitive for the analyzed solvents through a comprehensive validation according to the ICH guidelines.

11.
Anal Bioanal Chem ; 406(30): 7989-98, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25370161

RESUMEN

This paper reports the development of a method based on high-performance liquid chromatography (HPLC) coupled to second-order data modeling with multivariate curve resolution-alternating least-squares (MCR-ALS) for quantification of retinoic acid and its main isomers in plasma in only 5.5 min. The compounds retinoic acid (RA), 13-cis-retinoic acid, 9-cis-retinoic acid, and 9,13-di-cis-retinoic acid were partially separated by use of a Poroshell 120 EC-C18 (3.0 mm × 30 mm, 2.7 µm particle size) column. Overlapping not only among the target analytes but also with the plasma interferents was resolved by exploiting the second-order advantage of the multi-way calibration. A validation study led to the following results: trueness with recoveries of 98.5-105.9 % for RA, 95.7-110.1 % for 13-cis-RA, 97.1-110.8 % for 9-cis-RA, and 99.5-110.9 % for 9,13-di-cis-RA; repeatability with RSD of 3.5-3.1 % for RA, 3.5-1.5 % for 13-cis-RA, 4.6-2.7 % for 9-cis-RA, and 5.2-2.7 % for 9,13-di-cis-RA (low and high levels); and intermediate precision (inter-day precision) with RSD of 3.8-3.0 % for RA, 2.9-2.4 % for 13-cis-RA, 3.6-3.2 % for 9,13-di-cis-RA, and 3.2-2.9 % for 9-cis-RA (low and high levels). In addition, a robustness study revealed the method was suitable for monitoring patients with dermatological diseases treated with pharmaceutical products containing RA and 13-cis-RA.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Isotretinoína/sangre , Tretinoina/análogos & derivados , Alitretinoína , Cromatografía Líquida de Alta Presión/economía , Humanos , Isomerismo , Isotretinoína/aislamiento & purificación , Límite de Detección , Factores de Tiempo , Tretinoina/sangre , Tretinoina/aislamiento & purificación
12.
J Chromatogr A ; 1353: 40-8, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-24495791

RESUMEN

When determining endogenous compounds in biological samples, the lack of blank or analyte-free matrix samples involves the use of alternative strategies for calibration and quantitation. This article deals with the development, optimization and validation of a high performance liquid chromatography method for the determination of retinoic acid in plasma, obtaining at the same time information about its isomers, taking into account the basal concentration of these endobiotica. An experimental design was used for the optimization of three variables: mobile phase composition, flow rate and column temperature through a central composite design. Four responses were selected for optimization purposes (area under the peaks, quantity of peaks, analysis time and resolution between the first principal peak and the following one). The optimum conditions resulted in a mobile phase consisting of methanol 83.4% (v/v), acetonitrile 0.6% (v/v) and acid aqueous solution 16.0% (v/v); flow rate of 0.68 mL min(-1) and an column temperature of 37.10 °C. Detection was performed at 350 nm by a diode array detector. The method was validated following a holistic approach that included not only the classical parameters related to method performance but also the robustness and the expected proportion of acceptable results lying inside predefined acceptability intervals, i.e., the uncertainty of measurements. The method validation results indicated a high selectivity and good precision characteristics that were studied at four concentration levels, with RSD less than 5.0% for retinoic acid (less than 7.5% for the LOQ concentration level), in intra and inter-assay precision studies. Linearity was proved for a range from 0.00489 to 15.109 ng mL(-1) of retinoic acid and the recovery, which was studied at four different fortification levels in phuman plasma samples, varied from 99.5% to 106.5% for retinoic acid. The applicability of the method was demonstrated by determining retinoic acid and obtaining information about its isomers in human and frog plasma samples from different origins.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Tretinoina/sangre , Animales , Humanos , Isomerismo , Límite de Detección , Reproducibilidad de los Resultados , Tretinoina/química
13.
Artículo en Inglés | MEDLINE | ID: mdl-23376269

RESUMEN

A simple and fast on line spectrophotometric method combined with a hybrid hard-soft modeling multivariate curve resolution (HS-MCR) was proposed for the monitoring of photodegradation reaction of ciprofloxacin under UV radiation. The studied conditions attempt to emulate the effect of sunlight on these antibiotics that could be eventually present in the environment. The continuous flow system made it possible to study the ciprofloxacin degradation at different pH values almost at real time, avoiding errors that could arise from typical batch monitoring of the reaction. On the base of a concentration profiles obtained by previous pure soft-modeling approach, reaction pathways have been proposed for the parent compound and its photoproducts at different pH values. These kinetic models were used as a constraint in the HS-MCR analysis. The kinetic profiles and the corresponding pure response profile (UV-Vis spectra) of ciprofloxacin and its main degradation products were recovered after the application of HS-MCR analysis to the spectra recorded throughout the reaction. The observed behavior showed a good agreement with the photodegradation studies reported in the bibliography. Accordingly, the photodegradation reaction was studied by high performance liquid chromatography coupled with UV-Vis diode array detector (HPLC-DAD). The spectra recorded during the chromatographic analysis present a good correlation with the ones recovered by UV-Vis/HS-MCR method.


Asunto(s)
Antiinfecciosos/química , Ciprofloxacina/química , Fotólisis , Espectrofotometría/métodos , Estabilidad de Medicamentos , Diseño de Equipo , Concentración de Iones de Hidrógeno , Cinética , Modelos Químicos , Análisis Multivariante , Espectrofotometría/economía , Espectrofotometría/instrumentación , Rayos Ultravioleta
14.
Talanta ; 85(1): 142-50, 2011 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-21645683

RESUMEN

The development, optimization and validation of an ion-pairing high performance liquid chromatography method for the simultaneous determination of both nicarbazin (NIC) components: 4,4'-dinitrocarbanilide (DNC) and 2-hydroxy-4,6-dimethylpyrimidine (HDP) in bulk materials and feed additives are described. An experimental design was used for the optimization of the chromatographic system. Four variables, including mobile phase composition and oven temperature, were analyzed through a central composite design exploring their contribution to analyte separation. Five responses: peak resolutions, HDP capacity factor, HDP tailing and analysis time, were modelled by using the response surface methodology and were optimized simultaneously by implementing the desirability function. The optimum conditions resulted in a mobile phase consisting of 10.0 mmol L(-1) of 1-heptanesulfonate, 20.0 mmol L(-1) of sodium acetate, pH=3.30 buffer and acetonitrile in a gradient system at a flow rate of 1.00 mL min(-1). Column was an INERSTIL ODS-3 (4.6 mm×150 mm, 5 µm particle size) at 40.0°C. Detection was performed at 300 nm by a diode array detector. The validation results of the method indicated a high selectivity and good precision characteristics, with RSD less than 1.0% for both components, both in intra and inter-assay precision studies. Linearity was proved for a range of 32.0-50.0 µg mL(-1) of NIC in sample solution. The recovery, studied at three different fortification levels, varied from 98.0 to 101.4 for HDP and from 99.1 to 100.2 for DNC. The applicability of the method was demonstrated by determining DNC and HDP content in raw materials and commercial formulations used for coccidiosis prevention. Assays results on real samples showed that considerable differences in molecular ratio DNC:HDP exist among them.


Asunto(s)
Alimentación Animal/análisis , Cromatografía Líquida de Alta Presión/métodos , Nicarbazina/análisis , Animales , Carbanilidas/análisis , Coccidiosis/prevención & control , Coccidiostáticos , Pirimidinonas/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA