Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 258
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39237256

RESUMEN

OBJECTIVE: Intravenous epinephrine administration is preferred during neonatal resuscitation, but may not always be rapidly administered due to lack of equipment or trained staff. We aimed to compare the time to return of spontaneous circulation (ROSC) and post-ROSC haemodynamics between intravenous, endotracheal (ET) and intranasal (IN) epinephrine in severely asphyxic, bradycardic newborn lambs. METHODS: After instrumentation, severe asphyxia (heart rate <60 bpm, blood pressure ~10 mm Hg) was induced by clamping the cord in near-term lambs. Resuscitation was initiated with ventilation followed by chest compressions. Lambs were randomly assigned to receive intravenous (0.02 mg/kg), ET (0.1 mg/kg) or IN (0.1 mg/kg) epinephrine. If ROSC was not achieved after three allocated treatment doses, rescue intravenous epinephrine was administered. After ROSC, lambs were ventilated for 60 min. RESULTS: ROSC in response to allocated treatment occurred in 8/8 (100%) intravenous lambs, 4/7 (57%) ET lambs and 5/7 (71%) IN lambs. Mean (SD) time to ROSC was 173 (32) seconds in the intravenous group, 360 (211) seconds in the ET group and 401 (175) seconds in the IN group (p<0.05 intravenous vs IN). Blood pressure and cerebral oxygen delivery were highest in the intravenous group immediately post-ROSC (p<0.05), whereas the ET group sustained the highest blood pressure over the 60-min observation (p<0.05). CONCLUSION: Our study supports neonatal resuscitation guidelines, highlighting intravenous administration as the most effective route for epinephrine. ET and IN epinephrine should only be considered when intravenous access is delayed or not feasible.

2.
Acta Paediatr ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39215764

RESUMEN

AIM: Cardiorespiratory events in preterm infants pose a major challenge in the Neonatal Intensive Care Unit as they require a prompt response. We aimed to describe caregivers' responses to these events. METHODS: We performed a prospective observational study in 19 preterm infants (28 ± 2 weeks) on non-invasive respiratory support using video recordings of the inside of the incubator for 72 (55-72) h. Caregivers' responses to these events were then identified from the videos. RESULTS: We recorded and assessed 1851 cardiorespiratory events with a median duration of 11.0 (5.0-23.0) s. No response was observed in the majority of the events (91.5%). In the remaining 8.5% events, caregivers responded by pausing the alarm, adjusting devices and/or providing tactile stimulation with an average response time of 25.4 (13.8-35.9) s. Stimulation was the most observed response and was applied in 38 different ways. On average, stimulation lasted 18.7 (11.6-44.6) s and the cardiorespiratory events were resolved 30.6 (19.5-47.6) s after stimulation started. CONCLUSION: Our study showed that cardiorespiratory events are common in preterm infants in the NICU, but often not followed by intervention of the caregiver. The indication, timing and execution of responses to cardiorespiratory events is highly variable.

3.
Neonatology ; : 1-6, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39197438

RESUMEN

BACKGROUND: The timing of cord clamping has become a focal point for neonatal caregivers due to the promising outcomes associated with delayed cord clamping, which is a simple and cost-effective method to enhance the survival and well-being of preterm infants. While initially the rationale behind delaying clamping was to facilitate increased placental transfusion, research has unveiled additional hemodynamic benefits. SUMMARY: Experimental studies have demonstrated improved circulatory transition when clamping is postponed until the lungs are adequately aerated. This suggests that infants requiring assistance during the transition phase may benefit from stabilization while still attached to the cord. The Aeration, Breathing, and then Clamping (ABC) project aimed to translate these experimental findings into clinical practice. KEY MESSAGE: In this review, we will discuss the insights gained and lessons learned from the project's implementation.

5.
Pediatr Res ; 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977795

RESUMEN

BACKGROUND: As very preterm infants have surfactant-deficient and highly incompliant lungs, slowing lung deflation during expiration might help preserve functional residual capacity(FRC) during lung aeration. In this study, we investigated the effect of expiratory resistance(Re) on lung aeration during positive pressure ventilation in preterm rabbits immediately after birth. METHODS: Preterm rabbit pups were delivered at 29 days gestation, mechanically ventilated from birth and simultaneously imaged to measure lung aeration using phase-contrast X-ray. Re was varied by altering the length (0, 60 or 1000 mm) of the expiratory circuit. RESULTS: Increasing Re led to a decrease in lung deflation rates and both peak expiratory flows and flow rates at mid-deflation. As a result, the rate of de-acceleration(slowing) in lung deflation when approaching FRC was markedly reduced with increasing resistance. During lung aeration, FRC was significantly different between resistance groups and was significantly higher over time in the high compared to the low resistance group. While FRC values tended to be higher with higher Re, they were not significantly different at end-ventilation (t = 7 min). CONCLUSION: Increasing Re of the ventilation circuit during lung aeration in preterm rabbits immediately after birth decreased lung deflation rates and increased the accumulation of FRC over time. IMPACT: The expiratory phase of the ventilatory cycle has been largely overlooked as an opportunity to improve ventilation in preterm infants after birth. Increasing the expiratory resistance of the ventilator circuit during lung aeration in preterm rabbits immediately after birth markedly decreased lung deflation rates and increased FRC accumulation, compared to a low expiratory resistance. This indicates that ventilation devices that reduce the "work of breathing" by reducing the expiratory resistance, may have the unintended effect of reducing FRC, particularly in extremely preterm infants that have surfactant deficient highly incompliant lungs.

6.
BMJ Open Qual ; 13(2)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38749540

RESUMEN

Video review (VR) of procedures in the medical environment can be used to drive quality improvement. However, first it has to be implemented in a safe and effective way. Our primary objective was to (re)define a guideline for implementing interprofessional VR in a neonatal intensive care unit (NICU). Our secondary objective was to determine the rate of acceptance by providers attending VR. For 9 months, VR sessions were evaluated with a study group, consisting of different stakeholders. A questionnaire was embedded at the end of each session to obtain feedback from providers on the session and on the safe learning environment. In consensus meetings, success factors and preconditions were identified and divided into different factors that influenced the rate of adoption of VR. The number of providers who recorded procedures and attended VR sessions was determined. A total of 18 VR sessions could be organised, with an equal distribution of medical and nursing staff. After the 9-month period, 101/125 (81%) of all providers working on the NICU attended at least 1 session and 80/125 (64%) of all providers recorded their performance of a procedure at least 1 time. In total, 179/297 (61%) providers completed the questionnaire. Almost all providers (99%) reported to have a positive opinion about the review sessions. Preconditions and success factors related to implementation were identified and addressed, including improving the pathway for obtaining consent, preparation of VR, defining the role of the chair during the session and building a safe learning environment. Different strategies were developed to ensure findings from sessions were used for quality improvement. VR was successfully implemented on our NICU and we redefined our guideline with various preconditions and success factors. The adjusted guideline can be helpful for implementation of VR in emergency care settings.


Asunto(s)
Unidades de Cuidado Intensivo Neonatal , Mejoramiento de la Calidad , Grabación en Video , Humanos , Unidades de Cuidado Intensivo Neonatal/organización & administración , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Unidades de Cuidado Intensivo Neonatal/normas , Encuestas y Cuestionarios , Recién Nacido , Grabación en Video/métodos , Grabación en Video/estadística & datos numéricos , Investigación sobre Servicios de Salud/métodos
7.
Artículo en Inglés | MEDLINE | ID: mdl-38719430

RESUMEN

BACKGROUND: Planned caesarean section (CS) is a risk factor for neonatal respiratory distress caused by a greater volume of airway liquid in the absence of uterine contractions.Performing a newly conceptualised knee-to-chest flexion (KCF) manoeuvre at birth, mimicking uterine contraction-induced flexion may aid in expelling excess lung liquid. OBJECTIVES: To test whether performing a KCF manoeuvre at birth is feasible in infants born after planned CS and to test whether KCF leads to visible expulsion of lung liquid. METHODS: Single-centre prospective interventional study in term infants born by planned CS at Leiden University Medical Centre, Netherlands. KCF was performed for a maximum of 45 s. Baseline characteristics were collected, primary outcome was ability to perform KCF and secondary outcome was any visible expulsion of fluid. RESULTS: In 39 infants (mean (SD) gestational age 38.0 (0.7) weeks, birth weight 3537 (440) g), KCF could be performed in 21/39 (54%), whereas 18/39 (46.2%) starting vigorous breathing before KCF could be performed. Notably, visible lung liquid expulsion occurred in 9/21 (43%) infants. KCF duration averaged 29 (18) s. In 13/21 (62 %), KCF was not performed as per standard operating procedure. No adverse events were reported. CONCLUSION: It is feasible to perform KCF at birth in a large proportion of term infants born by planned CS, with visible expulsion of liquid in a significant proportion of these infants. Training healthcare providers to perform a standardised KCF could increase feasibility and success. Further studies are needed to assess feasibility and effectiveness of KCF. TRIAL REGISTRATION NUMBER: NL74285.058.20.

9.
Front Pediatr ; 12: 1360111, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38425664

RESUMEN

To improve care for extremely premature infants, the development of an extrauterine environment for newborn development is being researched, known as Artificial Placenta and Artificial Womb (APAW) technology. APAW facilitates extended development in a liquid-filled incubator with oxygen and nutrient supply through an oxygenator connected to the umbilical vessels. This setup is intended to provide the optimal environment for further development, allowing further lung maturation by delaying gas exposure to oxygen. This innovative treatment necessitates interventions in obstetric procedures to transfer an infant from the native to an artificial womb, while preventing fetal-to-neonatal transition. In this narrative review we analyze relevant fetal physiology literature, provide an overview of insights from APAW studies, and identify considerations for the obstetric procedure from the native uterus to an APAW system. Lastly, this review provides suggestions to improve sterility, fetal and maternal well-being, and the prevention of neonatal transition.

10.
Trials ; 25(1): 164, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38439024

RESUMEN

BACKGROUND: Mortality, cerebral injury, and necrotizing enterocolitis (NEC) are common complications of very preterm birth. An important risk factor for these complications is hemodynamic instability. Pre-clinical studies suggest that the timing of umbilical cord clamping affects hemodynamic stability during transition. Standard care is time-based cord clamping (TBCC), with clamping irrespective of lung aeration. It is unknown whether delaying cord clamping until lung aeration and ventilation have been established (physiological-based cord clamping, PBCC) is more beneficial. This document describes the statistical analyses for the ABC3 trial, which aims to assess the efficacy and safety of PBCC, compared to TBCC. METHODS: The ABC3 trial is a multicenter, randomized trial investigating PBCC (intervention) versus TBCC (control) in very preterm infants. The trial is ethically approved. Preterm infants born before 30 weeks of gestation are randomized after parental informed consent. The primary outcome is intact survival, defined as the composite of survival without major cerebral injury and/or NEC. Secondary short-term outcomes are co-morbidities and adverse events assessed during NICU admission, parental reported outcomes, and long-term neurodevelopmental outcomes assessed at a corrected age of 2 years. To test the hypothesis that PBCC increases intact survival, a logistic regression model will be estimated using generalized estimating equations (accounting for correlation between siblings and observations in the same center) with treatment and gestational age as predictors. This plan is written and submitted without knowledge of the data. DISCUSSION: The findings of this trial will provide evidence for future clinical guidelines on optimal cord clamping management at birth. TRIAL REGISTRATION: ClinicalTrials.gov NCT03808051. Registered on 17 January 2019.


Asunto(s)
Recien Nacido Prematuro , Nacimiento Prematuro , Lactante , Femenino , Recién Nacido , Humanos , Preescolar , Constricción , Recién Nacido de muy Bajo Peso , Respiración
11.
Trials ; 25(1): 198, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38509614

RESUMEN

BACKGROUND: Infants born with congenital diaphragmatic hernia (CDH) are at high risk of respiratory insufficiency and pulmonary hypertension. Routine practice includes immediate clamping of the umbilical cord and endotracheal intubation. Experimental animal studies suggest that clamping the umbilical cord guided by physiological changes and after the lungs have been aerated, named physiological-based cord clamping (PBCC), could enhance the fetal-to-neonatal transition in CDH. We describe the statistical analysis plan for the clinical trial evaluating the effects of PBCC versus immediate cord clamping on pulmonary hypertension in infants with CDH (PinC trial). DESIGN: The PinC trial is a multicentre, randomised controlled trial in infants with isolated left-sided CDH, born ≥ 35.0 weeks of gestation. The primary outcome is the incidence of pulmonary hypertension in the first 24 h after birth. Maternal outcomes include estimated maternal blood loss. Neonatal secondary outcomes include mortality before discharge, extracorporeal membrane oxygenation therapy, and number of days of mechanical ventilation. Infants are 1:1 randomised to either PBCC or immediate cord clamping using variable random permutated block sizes (4-8), stratified by treatment centre and estimated severity of pulmonary hypoplasia (i.e. mild/moderate/severe). At least 140 infants are needed to detect a relative reduction in pulmonary hypertension by one third, with 80% power and 0.05 significance level. A chi-square test will be used to evaluate the hypothesis that PBCC decreases the occurrence of pulmonary hypertension. This plan is written and submitted without knowledge of the collected data. The trial has been ethically approved. TRIAL REGISTRATION: ClinicalTrials.gov NCT04373902 (registered April 2020).


Asunto(s)
Hernias Diafragmáticas Congénitas , Hipertensión Pulmonar , Recién Nacido , Embarazo , Animales , Femenino , Humanos , Hernias Diafragmáticas Congénitas/diagnóstico , Clampeo del Cordón Umbilical , Constricción , Respiración Artificial/efectos adversos , Cordón Umbilical/cirugía
12.
Eur J Pediatr ; 183(5): 2455-2461, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38470520

RESUMEN

High concentrations of oxygen are often needed to optimize oxygenation in infants with persistent pulmonary hypertension (PPHN), but this can also increase the risk of hyperoxemia. We determined the occurrence of hyperoxemia in infants treated for PPHN. Medical records of infants ≥ 34 + 0 weeks gestational age (GA) who received inhaled nitric oxide (iNO) were retrospectively reviewed for oxygenation parameters during iNO therapy. Oxygen was manually titrated to target arterial oxygen tension (PaO2) 10-13 kPa and peripheral oxygen saturation (SpO2) 92-98%. The main study outcomes were the incidence and duration of hyperoxemia and hypoxemia and the fraction of inspired oxygen (FiO2). A total of 181 infants were included. The median FiO2 was 0.43 (IQR 0.34-0.56) and the maximum FiO2 was 1.0 in 156/181 (86%) infants, resulting in at least one PaO2 > 13 kPa in 149/181 (82%) infants, of which 46/149 (31%) infants had minimal one PaO2 > 30 kPa. SpO2 was > 98% in 179/181 (99%) infants for 17.7% (8.2-35.6%) of the iNO time. PaO2 < 10 kPa occurred in 160/181 (88%) infants, of which 81/160 (51%) infants had minimal one PaO2 < 6.7 kPa. SpO2 was < 92% in 169/181 (93%) infants for 1.6% (0.5-4.3%) of the iNO time.    Conclusion: While treatment of PPHN is focused on preventing and reversing hypoxemia, hyperoxemia occurs inadvertently in most patients. What is Known: • High concentrations of oxygen are often needed to prevent hypoxemia-induced deterioration of PPHN, but this can also increase the risk of hyperoxemia. • Infants with persistent pulmonary hypertension may be particularly vulnerable to the toxic effects of oxygen, and hyperoxemia could further induce pulmonary vasoconstriction, potentially worsening the condition. What is New: • Hyperoxemia occurs in the majority of infants with PPHN during treatment with iNO. • Infants with PPHN spent a considerably longer period with saturations above the target range compared to saturations below the target range.


Asunto(s)
Hiperoxia , Óxido Nítrico , Síndrome de Circulación Fetal Persistente , Humanos , Recién Nacido , Hiperoxia/etiología , Óxido Nítrico/administración & dosificación , Estudios Retrospectivos , Síndrome de Circulación Fetal Persistente/terapia , Masculino , Femenino , Administración por Inhalación , Oxígeno/sangre , Oxígeno/administración & dosificación , Saturación de Oxígeno , Terapia por Inhalación de Oxígeno/métodos , Hipoxia/etiología , Hipoxia/terapia
13.
Pediatr Res ; 96(2): 325-331, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38356025

RESUMEN

BACKGROUND: Manual tactile stimulation is used to counteract apnea in preterm infants, but it is unknown when this intervention should be applied. We compared an anticipatory to a reactive approach using vibrotactile stimulation to prevent hypoxia induced apneas. METHODS: Preterm rabbit kittens were prematurely delivered and randomized to either group. All kittens breathed spontaneously with a positive airway pressure of 8 cmH2O while they were imaged using phase contrast X-ray. Irregular breathing (IB) was induced using gradual hypoxia. The anticipatory group received stimulation at the onset of IB and the reactive group if IB transitioned into apnea. Breathing rate (BR), heart rate (HR) and functional residual capacity (FRC) were compared. RESULTS: Anticipatory stimulation significantly reduced apnea incidence and maximum inter-breath intervals and increased BR following IB, compared to reactive stimulation. Recovery in BR but not HR was more likely with anticipatory stimulation, although both BR and HR were significantly higher at 120 s after stimulation onset. FRC values and variability were not different. CONCLUSIONS: Anticipated vibrotactile stimulation is more effective in preventing apnea and enhancing breathing when compared to reactive stimulation in preterm rabbits. Stimulation timing is likely to be a key factor in reducing the incidence and duration of apnea. IMPACT: Anticipated vibrotactile stimulation can prevent apnea and stimulate breathing effort in preterm rabbits. Anticipated vibrotactile stimulation increases the likelihood of breathing rate recovery following hypoxia induced irregular breathing, when compared to reactive stimulation. Automated stimulation in combination with predictive algorithms may improve the treatment of apnea in preterm infants.


Asunto(s)
Animales Recién Nacidos , Apnea , Frecuencia Cardíaca , Hipoxia , Vibración , Animales , Conejos , Apnea/fisiopatología , Hipoxia/fisiopatología , Vibración/uso terapéutico , Frecuencia Respiratoria , Respiración , Capacidad Residual Funcional , Estimulación Física , Femenino , Modelos Animales de Enfermedad , Nacimiento Prematuro
14.
Pediatr Res ; 96(2): 299-308, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38356026

RESUMEN

BACKGROUND: The goal of every medical team is to provide optimal care for their patients. We aimed to use video review (VR) sessions to identify and address areas for improvement in neonatal care. METHODS: For nine months, neonatal procedures (stabilization at birth, intubations and sterile line insertions) were video recorded and reviewed with the neonatal care providers. Action research was used to identify and address areas for improvement which were categorized as (1) protocol/equipment adjustments, (2) input for research, (3) aspects of variety, or (4) development of educational material or training programs. RESULTS: Eighteen VR sessions were organized with a mean(SD) of 17(5) staff members participating. In total, 120 areas for improvement were identified and addressed, of which 84/120 (70%) were categorized as aspects of variety, 20/120 (17%) as development of educational material or training programs, 10/120 (8%) as protocol/equipment adjustments, and 6/120 (5%) as input for research. The areas for improvement were grouped in themes per category, including sterility, technique, equipment, communication, teamwork, parents' perspective and ventilation. CONCLUSION: Our study showed that regularly organized VR empowered healthcare providers to identify and address a large variety of areas for improvement, contributing to continuous learning and improvement processes. IMPACT: Video review empowered healthcare providers to identify areas for improvement in neonatal care Video review gave providers the opportunity to address identified areas for improvement, either by enhancing the application of external evidence (i.e. guidelines), learning from individual clinical expertise or strengthening resilience and teamwork Embedding regularly organized video review sessions allowed for continuous monitoring of care by providers, which can be beneficial for creating ongoing learning and improvement processes The structured pathways, supporting implementation of changes that were proposed based on the video review sessions, could help other centers make use of the potential video review has to offer.


Asunto(s)
Grabación en Video , Humanos , Recién Nacido , Mejoramiento de la Calidad , Grupo de Atención al Paciente , Neonatología/educación
15.
Arch Dis Child Fetal Neonatal Ed ; 109(5): 527-534, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38316547

RESUMEN

OBJECTIVE: To compare the effect of peripheral oxygen saturation (SpO2) target range (TR) (either 91%-95% and 92%-96%) on the frequency and duration of hypoxic and hyperoxic episodes while on automated oxygen control using the OxyGenie controller. DESIGN: Randomised cross-over study. SETTING: Tertiary-level neonatal unit in the Netherlands. PATIENTS: Infants (n=27) with a median (IQR) gestational age of 27+0 (25+5-27+3) weeks and postnatal age of 16 (10-22) days, receiving invasive or non-invasive respiratory support. INTERVENTIONS: In both groups supplemental oxygen was titrated to a TR of 91%-95% (TRlow) or 92%-96% (TRhigh) by the OxyGenie controller (SLE6000 ventilator) for 24 hours each, in random sequence. After a switch in TR, a 1-hour washout period was applied to prevent carry-over bias. MAIN OUTCOME MEASURES: Frequency and duration of hypoxic (SpO2<80% for ≥1 s) and hyperoxic episodes (SpO2>98% for ≥1 s). RESULTS: Hypoxic episodes were less frequent when the higher range was targeted (TRhigh vs TRlow: 2.5 (0.7-6.2)/hour vs 2.4 (0.9-10.2)/hour, p=0.02), but hyperoxic episodes were more frequent (5.3 (1.8-12.3)/hour vs 2.9 (1.0-7.1)/hour, p<0.001). The duration of the out-of-range episodes was not significantly different (hypoxia: 4.7 (2.8-7.1) s vs 4.4 (3.7-6.5) s, p=0.67; hyperoxia: 4.3 (3.3-4.9) s vs 3.9 (2.8-5.5) s, p=0.89). CONCLUSION: Targeting a higher SpO2 TR with the OxyGenie controller reduced hypoxic episodes but increased hyperoxic episodes. This study highlights the feasibility of using an automated oxygen titration device to explore the effects of subtle TR adjustments on clinical outcomes in neonatal care. TRIAL REGISTRATION NUMBER: NL9662.


Asunto(s)
Estudios Cruzados , Hiperoxia , Hipoxia , Recien Nacido Prematuro , Terapia por Inhalación de Oxígeno , Saturación de Oxígeno , Humanos , Recién Nacido , Terapia por Inhalación de Oxígeno/métodos , Femenino , Saturación de Oxígeno/fisiología , Masculino , Hiperoxia/prevención & control , Hipoxia/prevención & control , Edad Gestacional , Oxígeno/administración & dosificación , Oxígeno/sangre , Oximetría/métodos , Países Bajos , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Síndrome de Dificultad Respiratoria del Recién Nacido/prevención & control
16.
Arch Dis Child Fetal Neonatal Ed ; 109(5): 550-556, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38326027

RESUMEN

OBJECTIVE: To examine the providers' perceptions and experiences on implementation of video review (VR) of procedures in the neonatal intensive care unit (NICU). DESIGN: Qualitative study using semi-structured interviews with neonatal care providers about their experiences with VR. Interviews were audio-recorded, transcribed and thematically analysed using the data analysis software Atlas.ti V.22.2. SETTING: Providers working in the NICU of the Leiden University Medical Center were interviewed during implementation of VR. RESULTS: In total, 28 NICU staff members were interviewed. The interviewed providers appreciated VR and valued the focus on a safe learning environment. Five overarching themes were identified: (1) added value: providers reported that VR is a powerful tool for reflection on daily practice and serves as a magnifying glass on practice, provides a helicopter view and VR with nursing and medical staff together led to new insights and was seen as highly valuable; (2) preconditions and considerations: the existing culture of trust on the NICU positively influenced providers' perception; (3) adjustment: it was recommended to first let providers attend a VR session, before being recorded; (4) experiences with VR: suggestions were made by the providers regarding the preparation and organisation of VR and the role of the chair; (5) embedding VR: providers considered how to embed VR on the long-term while maintaining a safe learning environment and provided suggestions for expanding. CONCLUSION: Neonatal care providers appreciated the use of VR and provided viewpoints on how to implement VR successfully, which were used to develop a roadmap with recommendations.


Asunto(s)
Actitud del Personal de Salud , Unidades de Cuidado Intensivo Neonatal , Investigación Cualitativa , Grabación en Video , Humanos , Unidades de Cuidado Intensivo Neonatal/organización & administración , Recién Nacido , Femenino , Masculino , Cuidado Intensivo Neonatal/normas , Cuidado Intensivo Neonatal/métodos , Países Bajos
17.
J Appl Physiol (1985) ; 136(3): 630-642, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38328823

RESUMEN

Airway liquid is cleared into lung tissue after birth, which becomes edematous and forces the chest wall to expand to accommodate both the cleared liquid and incoming air. This study investigated how changing chest wall mechanics affects respiratory function after birth in near-term lambs with different airway liquid volumes. Surgically instrumented near-term lambs (139 ± 2 days) were randomized into Control (n = 7) or Elevated Liquid (EL; n = 6) groups. Control lambs had lung liquid drained to simulate expected volumes following vaginal delivery. EL lambs had airway liquid drained and 30 mL/kg liquid returned to simulate expected airway liquid volumes after elective cesarean section. Lambs were delivered, transferred to a Perspex box, and ventilated (30 min). Pressure in the box was adjusted to apply positive (7-8 cmH2O above atmospheric pressure) or negative (7-8 cmH2O below atmospheric pressure) pressures for 30 min before pressures were reversed. External negative pressures expanded the chest wall, reduced chest wall compliance (CCW) and increased lung compliance (CL) in Control and EL lambs. External positive pressures compressed the chest wall, increased CCW and reduced CL in Control and EL lambs. External negative pressure improved pulmonary oxygen exchange, reducing the alveolar-arterial difference in oxygen (AaDO2) by 69 mmHg (95% CI [13, 125]; P = 0.016) in Control lambs and by 300 mmHg (95% CI [233, 367]; P < 0.001) in EL lambs. In contrast, external positive pressures impaired pulmonary gas exchange, increasing the AaDO2 by 179 mmHg (95% CI [73, 285]; P = 0.002) in Control and by 215 mmHg (95% CI [89, 343]; P < 0.001) in EL lambs. The application of external thoracic pressures influences respiratory function after birth.NEW & NOTEWORTHY This study investigated how changes in chest wall mechanics influence respiratory function after birth. Our data indicate that the application of continuous external subatmospheric pressure greatly improves respiratory function in near-term lambs with respiratory distress, whereas external positive pressures impair respiratory function. Our findings indicate that, during neonatal resuscitation at birth, the forces applied to the chest wall should not be ignored as they can have a major impact on neonatal respiratory function.


Asunto(s)
Pared Torácica , Animales , Ovinos , Embarazo , Femenino , Cesárea , Resucitación , Respiración , Oxígeno , Animales Recién Nacidos , Mecánica Respiratoria
18.
Resuscitation ; 194: 110053, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37979668

RESUMEN

AIM: Studies in animals have shown that vocal cords (VCs) close during apnoea before and after birth, thereby impairing the effect of non-invasive ventilation. We tested the feasibility of visualising VCs using ultrasonography (US) and investigated the position and movement of the VCs during non-invasive respiratory support of preterm infants at birth. METHODS: In an observational study, VCs were visualised using US in infants <30 weeks gestation during both stabilisation after birth and at one hour after birth. Respiratory efforts were simultaneously recorded. The percentage of time the VCs were closed in the first ten minutes was determined from videoframes acquired at 15 Hz and compared with respiratory flow patterns measured using a respiratory function monitor. RESULTS: US of the VCs could be performed in 20/20 infants included (median (IQR) gestational age 27+6 (27+1-28+6) weeks) without interfering with stabilisation, of whom 60% (12/20) were initially breathing and 40% (8/20) were apnoeic at birth. In breathing infants, the VCs closed between breaths and during breath holds, which accounted for 57% (49-66) of the time. In apnoeic infants receiving positive pressure ventilation, the VCs were closed for 93% (81-99) of the time. US at one hour after birth could be performed in 14/20 infants, VCs were closed between breaths and during breath holds, accounting for 46% (27-52) of the time. CONCLUSION: Visualising VCs in preterm infants at birth using US is feasible. The VCs were closed during apnoea, in between breaths and during breath holds, impairing the effect of ventilation given.


Asunto(s)
Apnea , Recien Nacido Prematuro , Lactante , Recién Nacido , Humanos , Embarazo , Adulto , Femenino , Edad Gestacional , Pliegues Vocales , Respiración
19.
Catheter Cardiovasc Interv ; 103(2): 308-316, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091308

RESUMEN

BACKGROUND: Balloon atrial septostomy (BAS) is an emergent and essential cardiac intervention to enhance intercirculatory mixing at atrial level in deoxygenated patients diagnosed with transposition of the great arteries (TGA) and restrictive foramen ovale. The recent recall of several BAS catheters and the changes in the European legal framework for medical devices (MDR 2017/745), has led to an overall scarcity of BAS catheters and raised questions about the use, safety, and experience of the remaining NuMED Z-5 BAS catheter. AIMS: To evaluate and describe the practice and safety of the Z-5 BAS catheter, and to compare it to the performance of other BAS catheters. METHODS: A retrospective single-center cohort encompassing all BAS procedures performed with the Z-5 BAS catheter in TGA patients between 1999 and 2022. RESULTS: A total of 182 BAS procedures were performed in 179 TGA-newborns at Day 1 (IQR 0-5) days after birth, with median weight of 3.4 (IQR 1.2-5.7) kg. The need for BAS was urgent in 90% of patients. The percentage of BAS procedures performed at bedside increased over time from 9.8% (before 2010) to 67% (2017-2022). Major complication rate was 2.2%, consisting of cerebral infarction (1.6%) and hypovolemic shock (0.5%). The rate of minor complications was 9.3%, including temporary periprocedural AV-block (3.8%), femoral vein thrombosis (2.7%), transient intracardiac thrombus (0.5%), and atrial flutter (2.2%). BAS procedures performed at bedside and in the cardiac catheterization laboratory had similar complication rates. CONCLUSIONS: BAS using the Z-5 BAS catheter is both feasible and safe at bedside and at the cardiac catheterization laboratory with minimal major complications.


Asunto(s)
Transposición de los Grandes Vasos , Humanos , Recién Nacido , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Transposición de los Grandes Vasos/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Catéteres , Arterias
20.
Pediatr Res ; 95(3): 660-667, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37952056

RESUMEN

BACKGROUND: Infants with a congenital diaphragmatic hernia (DH) have underdeveloped lungs and require mechanical ventilation after birth, but the optimal approach is unknown. We hypothesised that sustained inflation (SI) increases lung aeration in newborn kittens with a DH. METHODS: In pregnant New Zealand white rabbits, a left-sided DH was induced in two fetal kittens per doe at 24-days gestation (term = 32 days); litter mates acted as controls. DH and control kittens were delivered by caesarean section at 30 days, intubated and mechanically ventilated (7-10 min) with either an SI followed by intermittent positive pressure ventilation (IPPV) or IPPV throughout. The rate and uniformity of lung aeration was measured using phase-contrast X-ray imaging. RESULTS: Lung weights in DH kittens were ~57% of controls. An SI increased the rate and uniformity of lung aeration in DH kittens, compared to IPPV, and increased dynamic lung compliance in both control and DH kittens. However, this effect of the SI was lost when ventilation changed to IPPV. CONCLUSION: While an SI improved the rate and uniformity of lung aeration in both DH and control kittens, greater consideration of the post-SI ventilation strategy is required to sustain this benefit. IMPACT: Compared to intermittent positive pressure ventilation (IPPV), an initial sustained inflation (SI) increased the rate and uniformity of lung aeration after birth. However, this initial benefit is rapidly lost following the switch to IPPV. The optimal approach for ventilating CDH infants at birth is unknown. While an SI improves lung aeration in immature lungs, its effect on the hypoplastic lung is unknown. This study has shown that an SI greatly improves lung aeration in the hypoplastic lung. This study will guide future studies examining whether an SI can improve lung aeration in infants with a CDH.


Asunto(s)
Hernias Diafragmáticas Congénitas , Humanos , Conejos , Animales , Embarazo , Femenino , Hernias Diafragmáticas Congénitas/diagnóstico por imagen , Hernias Diafragmáticas Congénitas/terapia , Animales Recién Nacidos , Cesárea , Pulmón/diagnóstico por imagen , Respiración Artificial/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA