Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Comput Assist Radiol Surg ; 14(8): 1389-1401, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31168671

RESUMEN

PURPOSE: Minimally invasive cochlear implant surgery is a challenging procedure due to high demands on accuracy. For clinical success, an according assistance system has to compete against the traditional approach in terms of risk, operating time and cost. It has not yet been determined what kind of system is the most suited. The purpose of this study is a proof of concept of surgical process modeling as a preclinical development tool and the comparison of workflow concepts for this new approach. METHODS: Three preclinical systems (two stereotactic and one robotic) for minimally invasive cochlear implant surgery are compared using the method of surgical process modeling. All three systems were successfully tested with ex vivo human specimen to create minimally invasive surgical access to the cochlea. Those systems where chosen for comparison, because they represent three diverse approaches with different corresponding workflows for the same intervention. The experiments were used to create a process model for each system by recording the interventions. RESULTS: All three conceptual systems developed by our group have shown their eligibility. The recorded process models provide a convenient method for direct comparison. Reduction in the surgical time has a higher impact on the process, than time that is needed for setting up a system beforehand. The stereotactic approaches have little preparation effort and are low cost in terms of hardware compared to the robotic approach, which in return is beneficial in terms of workload reduction for the surgeon. CONCLUSION: Surgical process modeling is suitable for comparison of different assistant systems for minimally invasive cochlear implantation. The benefit of reduced trauma, compared to the traditional mastoidectomy, can now be assessed with consideration of the workflow of each technique. The process models enable an assessment in the regard of surgical time and workload.


Asunto(s)
Cóclea/cirugía , Implantación Coclear/métodos , Implantes Cocleares , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Flujo de Trabajo , Algoritmos , Cadáver , Simulación por Computador , Diseño de Equipo , Humanos , Robótica , Grabación en Video
2.
Iran J Otorhinolaryngol ; 30(101): 321-327, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30560097

RESUMEN

INTRODUCTION: Different approaches have been developed to find the position of the internal auditory canal (IAC) in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory canal (IAC). MATERIALS AND METHODS: A combined OCT laser setup was used to outline the position of IAC on the surface of the petrous bone in cadaveric semi-heads. The position of the hidden structures, such as IAC, was determined in MATLAB software using an intraoperative CBCT scan. Four titanium spheres attached to the edge of the craniotomy served as reference markers visible in both CBCT and OCT images in order to transfer the plan to the patient. The integrated erbium-doped yttrium aluminum garnet laser was used to mark the surface of the bone by shallow ablation under OCT-based navigation before the surgeon continued the operation. RESULT: The technical setup was feasible, and the laser marking of the border of the IAC was performed with an overall accuracy of 300 µm. The depth of each ablation phase was 300 µm. The marks indicating a safe path supported the surgeon in the surgery. CONCLUSION: The technique investigated in the present study could decrease the surgical risks for the mentioned structures and improve the pace and precision of operation.

3.
Int J Comput Assist Radiol Surg ; 12(10): 1763-1773, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28707211

RESUMEN

PURPOSE: Assistance of robotic systems in the operating room promises higher accuracy and, hence, demanding surgical interventions become realisable (e.g. the direct cochlear access). Additionally, an intuitive user interface is crucial for the use of robots in surgery. Torque sensors in the joints can be employed for intuitive interaction concepts. Regarding the accuracy, they lead to a lower structural stiffness and, thus, to an additional error source. The aim of this contribution is to examine, if an accuracy needed for demanding interventions can be achieved by such a system or not. METHODS: Feasible accuracy results of the robot-assisted process depend on each work-flow step. This work focuses on the determination of the tool coordinate frame. A method for drill axis definition is implemented and analysed. Furthermore, a concept of admittance feed control is developed. This allows the user to control feeding along the planned path by applying a force to the robots structure. The accuracy is researched by drilling experiments with a PMMA phantom and artificial bone blocks. RESULTS: The described drill axis estimation process results in a high angular repeatability ([Formula: see text]). In the first set of drilling results, an accuracy of [Formula: see text] at entrance and [Formula: see text] at target point excluding imaging was achieved. With admittance feed control an accuracy of [Formula: see text] at target point was realised. In a third set twelve holes were drilled in artificial temporal bone phantoms including imaging. In this set-up an error of [Formula: see text] and [Formula: see text] was achieved. CONCLUSION: The results of conducted experiments show that accuracy requirements for demanding procedures such as the direct cochlear access can be fulfilled with compliant systems. Furthermore, it was shown that with the presented admittance feed control an accuracy of less then [Formula: see text] is achievable.


Asunto(s)
Cóclea/cirugía , Fantasmas de Imagen , Robótica/instrumentación , Cirugía Asistida por Computador/métodos , Hueso Temporal/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Cóclea/diagnóstico por imagen , Humanos , Hueso Temporal/cirugía
4.
Int J Comput Assist Radiol Surg ; 10(3): 285-92, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24923473

RESUMEN

PURPOSE: The integration of a robot into an image-guided therapy system is still a time consuming process, due to the lack of a well-accepted standard for interdevice communication. The aim of this project is to simplify this procedure by developing an open interface based on three interface classes: state control, visualisation, and sensor. A state machine on the robot control is added to the concept because the robot has its own workflow during surgical procedures, which differs from the workflow of the surgeon. METHODS: A KUKA Light Weight Robot is integrated into the medical technology environment of the Institute of Mechatronic Systems as a proof of concept. Therefore, 3D Slicer was used as visualisation and state control software. For the network communication the OpenIGTLink protocol was implemented. In order to achieve high rate control of the robot the "KUKA Sunrise. Connectivity SmartServo" package was used. An exemplary state machine providing states typically used by image-guided therapy interventions, was implemented. Two interface classes, which allow for a direct use of OpenIGTLink for robot control on the one hand and visualisation on the other hand were developed. Additionally, a 3D Slicer module was written to operate the state control. RESULTS: Utilising the described software concept the state machine could be operated by the 3D Slicer module with 20 Hz cycle rate and no data loss was detected during a test phase of approximately 270s (13,640 packages). Furthermore, the current robot pose could be sent with more than 60 Hz. No influence on the performance of the state machine by the communication thread could be measured. CONCLUSION: Simplified integration was achieved by using only one programming context for the implementation of the state machine, the interfaces, and the robot control. Eventually, the exemplary state machine can be easily expanded by adding new states.


Asunto(s)
Algoritmos , Robótica/instrumentación , Cirugía Asistida por Computador/instrumentación , Diseño de Equipo , Humanos , Imagenología Tridimensional , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA