Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Curr Probl Cardiol ; 47(9): 100859, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33994025

RESUMEN

Global incidence and prevalence of hypertension continues to increase and remains a significant challenge. The ever-increasing number of cases are due to comorbid conditions such as obesity and diabetes, as well as lifestyle indiscretions such as excessive salt intake. Hypertension, congestive heart failure, and kidney disease are all conditions resulting from abnormal Renin-Angiotensin-Aldosterone activation and adverse remodeling. Firibastat, a novel Brain Aminopeptidase inhibitor, may be able to help achieve blood pressure control in those with resistant hypertension. In this review article, we will discuss the biochemical pathway of firibastat and various trials assessing drug efficacy in animals and humans. This drug has the potential to curb the risk of uncontrolled hypertension and help improve long term cardiovascular morbidity and mortality.


Asunto(s)
Antihipertensivos , Disulfuros , Hipertensión , Ácidos Sulfónicos , Aminopeptidasas/antagonistas & inhibidores , Animales , Antihipertensivos/farmacología , Antihipertensivos/uso terapéutico , Encéfalo , Disulfuros/farmacología , Humanos , Hipertensión/tratamiento farmacológico , Sistema Renina-Angiotensina , Ácidos Sulfónicos/farmacología
2.
Curr Probl Cardiol ; 46(4): 100765, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33385749

RESUMEN

Drug-induced myopathy is a well-described clinical entity characterized by muscle damage leading to symptoms ranging from myalgias to rhabdomyolysis and acute kidney injury. Many pharmacotherapies are known to precipitate myopathic symptoms. Recent case reports suggest a potential relationship between the use of sodium/glucose cotransport 2 (SGLT2) inhibitors and onset of myopathy. The pathogenesis of this has yet to be elucidated. The relevance of this association is augmented by the recent popularity of SGLT2 inhibitors as well as the tendency for them to be prescribed alongside statins. This study reviewed the literature on the incidence and mechanism of drug-induced myopathy in patients with type 2 diabetes mellitus who are taking SGLT2 inhibitors with and without the use of statins.


Asunto(s)
Diabetes Mellitus Tipo 2 , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Enfermedades Musculares , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Animales , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Enfermedades Musculares/inducido químicamente , Enfermedades Musculares/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Transportador 2 de Sodio-Glucosa , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos
3.
J Interv Cardiol ; 2019: 1906814, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772515

RESUMEN

OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the Evolut PRO to the Evolut R valve in a real-world setting. BACKGROUND: The next-generation self-expanding transcatheter aortic valve replacement (TAVR) system, the CoreValve Evolut PRO was designed with an outer pericardial skirt to improve valve-sealing performance. Safety and efficacy of this valve have not previously been compared to its predecessor, the Evolut R valve. METHODS: We retrospectively studied 134 patients who underwent TAVR with the Evolut PRO or Evolut R valve over one year at a tertiary center. Endpoints, defined by the Valve Academic Research Consortium-2 criteria, included device success, paravalvular leak (PVL), and a composite safety endpoint including mortality, stroke, major vascular complications, life-threatening bleeding, acute kidney injury, coronary artery obstruction, and repeat procedure for valve-related dysfunction. RESULTS: 60 Evolut PRO and 56 Evolut R patients met the study criteria. Both groups had similar device success rates (90 vs. 89%, p=0.44). Incidence of moderate PVL was similar on discharge (5 vs. 11%, p=0.68) and at 30 days (11 vs. 13%, p=0.79), with nil incidence of severe PVL. There were no mortalities, and the VARC-2 safety endpoint at 30 days was comparable. CONCLUSION: Despite the additional pericardial skirt and larger sheath size of Evolut PRO, outcomes were comparable between the two Evolut systems, supporting adoption of the newest generation valve in the management of severe aortic stenosis as well as continued use of the Evolut R in patients with smaller vasculature warranting a lower profile device.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Lesión Renal Aguda/epidemiología , Anciano de 80 o más Años , Valvuloplastia con Balón/estadística & datos numéricos , Femenino , Hemorragia/epidemiología , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos
4.
Clin Case Rep ; 5(8): 1409-1410, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28781869

RESUMEN

Unidentified fractures of indwelling tunneled catheters are presumably rare and possibly underreported, but their consideration is important in patients with a history of catheter placement with otherwise unexplained, atypical chest pain.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA