1.
Opt Express ; 20(16): 18362-9, 2012 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-23038387

RESUMEN

We present a laser plasma based x-ray microscope for the water window employing a high-average power laser system for plasma generation. At 90 W laser power a brightness of 7.4 x 10(11) photons/(s x sr x µm(2)) was measured for the nitrogen Lyα line emission at 2.478 nm. Using a multilayer condenser mirror with 0.3 % reflectivity 10(6) photons/(µm(2) x s) were obtained in the object plane. Microscopy performed at a laser power of 60 W resolves 40 nm lines with an exposure time of 60 s. The exposure time can be further reduced to 20 s by the use of new multilayer condenser optics and operating the laser at its full power of 130 W.

2.
Phys Med Biol ; 57(9): 2603-17, 2012 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-22505599

RESUMEN

We demonstrate a laboratory method for imaging small blood vessels using x-ray propagation-based phase-contrast imaging and carbon dioxide (CO(2)) gas as a contrast agent. The limited radiation dose in combination with CO(2) being clinically acceptable makes the method promising for small-diameter vascular visualization. We investigate the possibilities and limitations of the method for small-animal angiography and compare it with conventional absorption-based x-ray angiography. Photon noise in absorption-contrast imaging prevents visualization of blood vessels narrower than 50 µm at the highest radiation doses compatible with living animals, whereas our simulations and experiments indicate the possibility of visualizing 20 µm vessels at radiation doses as low as 100 mGy. Experimental computed tomography of excised rat kidney shows blood vessels of diameters down to 60 µm with improved image quality compared to absorption-based methods. With our present prototype x-ray source, the acquisition time for a tomographic dataset is approximately 1 h, which is long compared to the 1-20 min common for absorption-contrast micro-CT systems. Further development of the liquid-metal-jet microfocus x-ray sources used here and high-resolution x-ray detectors shows promise to reduce exposure times and make this high-resolution method practical for imaging of living animals.


Asunto(s)
Angiografía/métodos , Dióxido de Carbono , Medios de Contraste , Microtomografía por Rayos X/métodos , Absorción , Animales , Vasos Sanguíneos/anatomía & histología , Imagenología Tridimensional , Riñón/irrigación sanguínea , Modelos Biológicos , Dosis de Radiación , Ratas
3.
Rev Sci Instrum ; 82(12): 123701, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22225218

RESUMEN

We present a high-brightness 24-keV electron-impact microfocus x-ray source based on continuous operation of a heated liquid-indium/gallium-jet anode. The 30-70 W electron beam is magnetically focused onto the jet, producing a circular 7-13 µm full width half maximum x-ray spot. The measured spectral brightness at the 24.2 keV In K(α) line is 3 × 10(9) photons∕(s × mm(2) × mrad(2) × 0.1% BW) at 30 W electron-beam power. The high photon energy compared to existing liquid-metal-jet sources increases the penetration depth and allows imaging of thicker samples. The applicability of the source in the biomedical field is demonstrated by high-resolution imaging of a mammography phantom and a phase-contrast angiography phantom.


Asunto(s)
Diagnóstico por Imagen/métodos , Galio/química , Indio/química , Angiografía , Calor , Mamografía , Fantasmas de Imagen , Rayos X
4.
J Microsc ; 226(Pt 2): 175-81, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17444946

RESUMEN

We demonstrate compact full-field soft X-ray transmission microscopy with sub 60-nm resolution operating at lambda= 2.48 nm. The microscope is based on a 100-Hz regenerative liquid-nitrogen-jet laser-plasma source in combination with a condenser zone plate and a micro-zone plate objective for high-resolution imaging onto a 2048 x 2048 pixel CCD detector. The sample holder is mounted in a helium atmosphere and allows imaging of both dry and wet specimens. The microscope design enables fast sample switching and the sample can be pre-aligned using a visible-light microscope. High-quality images can be acquired with exposure times of less than 5 min. We demonstrate the performance of the microscope using both dry and wet samples.


Asunto(s)
Microscopía/métodos , Animales , Células COS , Chlorocebus aethiops , Diatomeas/ultraestructura , Diseño de Equipo , Microscopía/instrumentación , Rayos X
5.
J Microsc ; 225(Pt 1): 80-7, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17286697

RESUMEN

Colloidal gold is a useful marker for functional-imaging experiments in transmission X-ray microscopy. Due to the low contrast of gold particles with small diameters it is necessary to develop a powerful algorithm to localize the single gold particles. The presented image-analysis algorithm for identifying colloidal gold particles is based on the combination of a threshold with respect to the local absorption and shape discrimination, realized by fitting a Gaussian profile to the identified regions of interest. The shape discrimination provides the possibility of size-selective identification and localization of single colloidal gold particles down to a diameter of 50 nm. The image-analysis algorithm, therefore, has potential for localization studies of several proteins simultaneously and for localization of fiducial markers in X-ray tomography.