1.
Sci Rep ; 11(1): 7285, 2021 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-33790400

RESUMEN

Maintaining oral function in older individuals with missing teeth is important for leading a healthy and independent life. This study aimed to evaluate whether simple isometric exercises can maintain and improve the oral function [maximum occlusal force (MOF) and masticatory ability (MA)] and the masticatory muscle properties [masseter muscle thickness (MMT) and echo intensity (MMEI)] in older adults during the maintenance phase of removable prosthetic treatment. Participants were randomly categorized into the intervention and control groups. The mouthpieces were distributed, and participants were instructed to use them for exercising. The intervention group was instructed to perform maximum clenching for 10 s, whereas the control group was instructed to tap the teeth at an arbitrary speed for 10 s. Both were repeated five times at an interval of 5 s between each activity and twice daily for 4 weeks. The outcomes were measured after a month of exercise. The intervention group showed a significant improvement in the MOF, MMT during contraction, MMT at rest and MMEI during contraction. There were no significant differences in the MA and MMEI at rest. In the control group, no improvement was observed in any of the parameters. When the isometric exercises were performed using a mouthpiece, there was an improvement in the oral function and masseter muscle properties in older individuals with Eichner B status who used dentures.


Asunto(s)
Terapia por Ejercicio/métodos , Músculo Masetero/fisiopatología , Boca Edéntula/rehabilitación , Anciano , Anciano de 80 o más Años , Oclusión Dental , Terapia por Ejercicio/instrumentación , Femenino , Humanos , Contracción Isométrica , Masculino , Músculo Masetero/fisiología , Masticación
3.
Rev Sci Instrum ; 91(11): 115001, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33261432

RESUMEN

This paper reports on the design and characteristics of a compact module integrating an optical displacement sensor and an electromagnetic actuator for use with vibration-isolation systems installed in KAGRA, the 3-km baseline gravitational-wave detector in Japan. In the technical concept, the module belongs to a family tree of similar modules used in other interferometric gravitational-wave detector projects. After the initial test run of KAGRA in 2016, the sensor part, which is a type of slot sensor, was modified by increasing the spacing of the slot from 5 mm to 15 mm to avoid the risk of mechanical interference with the sensor flag. We confirm that the sensor performance is comparable to that of the previous design despite the modification. We also confirm that the sensor noise is consistent with the theoretical noise budget. The noise level is 0.5 nm/Hz1/2 at 1 Hz and 0.1 nm/Hz1/2 at 10 Hz, and the linear range of the sensor is 0.7 mm or more. We measured the response of the actuator to be 1 N/A and also measured the resistances and inductances of coils of the actuators to confirm consistency with theory. Coupling coefficients among the different degrees of freedom were also measured and shown to be negligible, varying little between designs. A potential concern about thermal noise contribution due to eddy current loss is discussed. As of 2020, 42 of the modules are in operation at the site.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA