Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
Am. j. cardiol ; Am. j. cardiol;125(9): 1369-1377, May., 2020. graf.
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1099637

RESUMEN

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica
2.
JACC cardiovasc. interv ; 12(5): 433-443, Mar. 2019. tabela, gráfico
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024526

RESUMEN

Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)


Asunto(s)
Humanos , Reemplazo de la Válvula Aórtica Transcatéter
3.
Prog Cardiovasc Dis ; 60(4-5): 500-507, 2018. graf, tab
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1065739

RESUMEN

BACKGROUND: Diabetic patients account for an increasing number of patients undergoing percutaneous coronary intervention (PCI). However, diabetes mellitus (DM) is associated with increased residual platelet activity during dual antiplatelet treatment (DAPT) and DM patients have worse clinical outcomes after PCI as compared to non-DM. OBJECTIVE: To evaluate efficacy and safety of short duration DAPT (S-DAPT) and long duration DAPT (L-DAPT) after drug eluting stent (DES) implantation in DM and non-DM patients.METHODS:We searched Medline, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) to identify randomized controlled trials (RCTs) assessing the effect of S-DAPT versus L-DAPT after DES implantation in DM and non-DM patients. Efficacy endpoints were all-cause mortality, cardiac mortality, myocardial infarction (MI), stent thrombosis (ST), target vessel revascularization (TVR), and composite end point of net adverse clinical events (NACE) (all-cause mortality, cardiac mortality, MI, ST, TVR, stroke, major bleeding). Safety endpoints were major bleeding and stroke. Event rates were compared using a forest plot of relative risk using a random effects model...


Asunto(s)
Diabetes Mellitus , Stents Liberadores de Fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA