Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 374(7-8): 1230-6, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12474090

RESUMEN

In line with recent European environmental guidelines on biomasses, one of the most important parameters to take into account is the As concentration, especially when present in biomasses and complex matrices. The goal of the present study is to give information about possible technical-analytical problems during the determinations of such elements by means of different instrumental spectroscopy techniques, in particular inductively coupled plasma atomic emission (ICP-AES) and atomic absorption (AAS), using two different wavelengths, 188.98 nm and 193.70 nm. In the Laboratory of Hygiene of National Institute of Health in Italy, a specific study has been carried out concerning the determination of As contents in environmental solid matrices, using as reference material BCR 141 R, represented by a calcareous soil. In particular, whereas recovery tests did not show particular drawbacks, difficulties were met in the As detection in reference material. Spectral interference was seen during determination by ICP-AES and matrix interference during determination by AAS, in particular using ETAAS with deuterium background correction and HAAS. Using ETAAS with Zeeman background correction at 193.70 nm, the As line did not show particular matrix interference during the reading of samples.A ring test involving two more laboratories and another certified reference material (IAEA-356 in marine sediment matrix) produced important information about problems of under/over estimation of data. Two different instrumental techniques, ICP-MS and HAAS, confirmed previous data, i.e., overestimation for inductively coupled plasma mass spectrometry and that As values achieved by HAAS were of the same order as the references, but affected by considerable standard deviation. In the light of this study, data achieved on the environmental matrices investigated suggest that the critical step in As determination is the instrumental reading, rather than the mineralization process. Further, each of the methods proposed, apart from ETAAS with Zeeman background correction, presents its own peculiar drawbacks and no particular advantage over other techniques.


Asunto(s)
Arsénico/análisis , Contaminantes del Suelo/análisis , Espectrofotometría Atómica , Factores de Tiempo
2.
Ann Chim ; 90(11-12): 629-36, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11218249

RESUMEN

A preliminary study, based particularly on Arsenic and some heavy metals determination (Cd, Cr, Hg and Pb) in three leachate tipologies produced from municipal waste landfill plant, lab-scale aerobic landfill, lab-scale anerobic landfill was undertaken. Leachate was collected and analysed monthly; samples were homogenized and then, all heavy metals were determined after mineralization, except for Hg, determined before mineralization, due to his high volatility. In all samples pH was measured. In general we can say that low concentrations of the elements analyzed were found in all kinds of landfills considered; in particular, in the lab-scale anaerobic reactors, where low pH values have been found, we have a more considerable mobilization of As and the others heavy metals, moreover due to the behaviour of these elements.


Asunto(s)
Arsénico/análisis , Residuos Peligrosos/análisis , Metales Pesados/análisis , Eliminación de Residuos , Aerobiosis , Anaerobiosis , Reactores Biológicos , Concentración de Iones de Hidrógeno , Mercurio/análisis , Administración de Residuos , Contaminación del Agua/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA