Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Luminescence ; 19(5): 287-95, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15449348

RESUMEN

Many genomic assays rely on a distance-dependent interaction between luminescent labels, such as luminescence quenching or resonance energy transfer. We studied the interaction between electrochemically excited Ru(bpy)(3) (2+) and Cy5 in a hybridization assay on a chip. The 3' end of an oligonucleotide was labelled with Ru(bpy)(3) (2+) and the 5' end of a complementary strand with Cy5. Upon the hybridization, the electrochemiluminescence (ECL) of Ru(bpy)(3) (2+) was efficiently quenched by Cy5 with a sensitivity down to 30 nmol/L of the Cy5-labelled complementary strand. The quenching efficiency is calculated to be 78%. A similar phenomenon was observed in a comparative study using laser-excitation of Ru(bpy)(3) (2+). The hybridization with the non-labelled complementary or labelled non-complementary strand did not change the intensity of the ECL signal. Resonance energy transfer, electron transfer and static quenching mechanisms are discussed. Our results suggest that static quenching and/or electron transfer are the most likely quenching mechanisms.


Asunto(s)
Mediciones Luminiscentes , Hibridación de Ácido Nucleico/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Oligonucleótidos/química , Carbocianinas/química , Electroquímica , Genoma , Compuestos Organometálicos/química , Sensibilidad y Especificidad
2.
Electrophoresis ; 24(21): 3674-8, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14613192

RESUMEN

This paper characterizes the basic electrokinetic phenomena occurring within native poly(dimethylsiloxane) (PDMS) microchannels. Using simple buffers and current measurements, current density and electroosmosis data were determined in trapezoidal, reversibly sealed PDMS/PDMS and hybrid PDMS/glass channels with a cross-sectional area of 1035.5 microm(2) and about 6 cm length. This data was then compared to that obtained in an air-thermostated 50 microm inner diameter (1963.5 microm(2) cross-sectional area) fused-silica (FS) capillary of 70 cm length. Having a pH 7.8 buffer with an ionic strength (I) of 90 mM, Ohms's law was observed in the microchannels with electric field strengths of up to about 420 V/cm, which is about twice as high as for the FS capillary. The electroosmotic mobility (micro(EO)) in PDMS and FS is shown to exhibit the same general dependences on I and pH. For all configurations tested, the experimentally determined micro(EO) values were found to correlate well with the relationship micro(EO) = a + b log(I), where a and b are coefficients that are determined via nonlinear regression analysis. Electroosmotic fluid pumping in native PDMS also follows a pH dependence that can be estimated with a model based upon the ionization of silanol. Compared to FS, however, the magnitude of the electroosmotic flow in native PDMS is 50-70% smaller over the entire pH range and is difficult to maintain at acidic pH values. Thus, the origin of the negative charge at the inner wall of PDMS, glass, and FS appears to be similar but the density is lower for PDMS than for glass and FS.


Asunto(s)
Dimetilpolisiloxanos , Siliconas , Electroquímica/métodos , Miniaturización , Ósmosis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA