Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Arq. bras. cardiol ; Arq. bras. cardiol;121(8): e20230771, ago. 2024. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1568816

RESUMEN

Resumo Fundamento A frequência cardíaca (FC) na insuficiência cardíaca com fração de ejeção reduzida (ICFEr) e ritmo sinusal apresenta valor prognóstico. Entretanto, o método de mensuração é debatido na literatura. Objetivos Comparar em pacientes com ICFEr e ritmo sinusal a FC no Holter com três eletrocardiogramas de repouso: ECG1, ECG2 e ECG3. Metodologia Estudo transversal com 135 pacientes portadores de insuficiência cardíaca com fração de ejeção ≤ 40% e ritmo sinusal. A FC foi avaliada por ECG e Holter. Análises incluíram o coeficiente de correlação intraclasse (CCI), regressão robusta, raiz do erro quadrático médio, Bland-Altman e a área sobre a curva ROC. Adotou-se nível de significância de 0,05 e o ajuste de Bonferroni-Holm para minimizar erros tipo I. Resultados As medianas [intervalo interquartil] de idade e fração de ejeção foram de 65 anos [16] e 30% [11], respectivamente. O CCI dos 3 ECG foi de 0,922 (intervalo de confiança de 95%: 0,892; 0,942). Os coeficientes de regressão robusta para ECG1 e ECG3 foram 0,20 (intervalo de confiança de 95%: 0,12; 0,29) e 0,21 (intervalo de confiança de 95%: 0,06; 0,36). O R2 robusto foi de 0,711 (intervalo de confiança de 95%: 0,628; 0,76). Na análise de concordância de Bland-Altman, os limites de concordância foram de −17,0 (intervalo de confiança de 95%: −19,0; −15,0) e 32,0 (intervalo de confiança de 95%: 30,0; 34,0). A área sob a curva ROC foi de 0,896 (intervalo de confiança de 95%: 0,865; 0,923). Conclusão A FC do ECG mostrou alta concordância com a FC do Holter, validando seu uso clínico em pacientes com ICFEr e ritmo sinusal. Contudo, a concordância foi subótima em um terço dos pacientes com FC inferior a 70 bpm pelo ECG, devendo ser considerada a realização de Holter neste contexto.


Abstract Background Heart rate (HR) has shown prognostic value in patients with heart failure with reduced ejection fraction (HFrEF) and sinus rhythm. However, the method of measurement is debated in the literature. Objectives To compare HR on Holter with 3 resting electrocardiograms (ECG1, ECG2, and ECG3) in patients with HFrEF and sinus rhythm. Methods This was a cross-sectional study with 135 patients with heart failure with ejection fraction ≤ 40% and sinus rhythm. HR was assessed by ECG and Holter. Analyses included intraclass correlation coefficient (ICC), robust regression, root mean squared error, Bland-Altman, and area under the receiver operating characteristic (ROC) curve. A significance level of 0.05 and Bonferroni-Holm adjustment were adopted to minimize type I errors. Results The median [interquartile range] age and ejection fraction were 65 years [16] and 30% [11], respectively. The ICC of the 3 ECGs was 0.922 (95% confidence interval: 0.892; 0.942). The robust regression coefficients for ECG1 and ECG3 were 0.20 (95% confidence interval: 0.12; 0.29) and 0.21 (95% confidence interval: 0.06; 0.36). The robust R2 was 0.711 (95% confidence interval: 0.628; 0.76). In the Bland-Altman agreement analysis, the limits of agreement were −17.0 (95% confidence interval: −19.0; −15.0) and 32.0 (95% confidence interval: 30.0; 34.0). The area under the ROC curve was 0.896 (95% confidence interval: 0.865; 0.923). Conclusion The HR on ECG showed high agreement with the HR on Holter, validating its clinical use in patients with HFrEF and sinus rhythm. However, agreement was suboptimal in one third of patients with HR below 70 bpm on ECG; thus, 24-hour Holter monitoring should be considered in this context.

2.
Arq Bras Cardiol ; 121(8): e20230771, 2024 Aug.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-39194043

RESUMEN

BACKGROUND: Heart rate (HR) has shown prognostic value in patients with heart failure with reduced ejection fraction (HFrEF) and sinus rhythm. However, the method of measurement is debated in the literature. OBJECTIVES: To compare HR on Holter with 3 resting electrocardiograms (ECG1, ECG2, and ECG3) in patients with HFrEF and sinus rhythm. METHODS: This was a cross-sectional study with 135 patients with heart failure with ejection fraction ≤ 40% and sinus rhythm. HR was assessed by ECG and Holter. Analyses included intraclass correlation coefficient (ICC), robust regression, root mean squared error, Bland-Altman, and area under the receiver operating characteristic (ROC) curve. A significance level of 0.05 and Bonferroni-Holm adjustment were adopted to minimize type I errors. RESULTS: The median [interquartile range] age and ejection fraction were 65 years [16] and 30% [11], respectively. The ICC of the 3 ECGs was 0.922 (95% confidence interval: 0.892; 0.942). The robust regression coefficients for ECG1 and ECG3 were 0.20 (95% confidence interval: 0.12; 0.29) and 0.21 (95% confidence interval: 0.06; 0.36). The robust R2 was 0.711 (95% confidence interval: 0.628; 0.76). In the Bland-Altman agreement analysis, the limits of agreement were -17.0 (95% confidence interval: -19.0; -15.0) and 32.0 (95% confidence interval: 30.0; 34.0). The area under the ROC curve was 0.896 (95% confidence interval: 0.865; 0.923). CONCLUSION: The HR on ECG showed high agreement with the HR on Holter, validating its clinical use in patients with HFrEF and sinus rhythm. However, agreement was suboptimal in one third of patients with HR below 70 bpm on ECG; thus, 24-hour Holter monitoring should be considered in this context.


FUNDAMENTO: A frequência cardíaca (FC) na insuficiência cardíaca com fração de ejeção reduzida (ICFEr) e ritmo sinusal apresenta valor prognóstico. Entretanto, o método de mensuração é debatido na literatura. OBJETIVOS: Comparar em pacientes com ICFEr e ritmo sinusal a FC no Holter com três eletrocardiogramas de repouso: ECG1, ECG2 e ECG3. METODOLOGIA: Estudo transversal com 135 pacientes portadores de insuficiência cardíaca com fração de ejeção ≤ 40% e ritmo sinusal. A FC foi avaliada por ECG e Holter. Análises incluíram o coeficiente de correlação intraclasse (CCI), regressão robusta, raiz do erro quadrático médio, Bland-Altman e a área sobre a curva ROC. Adotou-se nível de significância de 0,05 e o ajuste de Bonferroni-Holm para minimizar erros tipo I. RESULTADOS: As medianas [intervalo interquartil] de idade e fração de ejeção foram de 65 anos [16] e 30% [11], respectivamente. O CCI dos 3 ECG foi de 0,922 (intervalo de confiança de 95%: 0,892; 0,942). Os coeficientes de regressão robusta para ECG1 e ECG3 foram 0,20 (intervalo de confiança de 95%: 0,12; 0,29) e 0,21 (intervalo de confiança de 95%: 0,06; 0,36). O R2 robusto foi de 0,711 (intervalo de confiança de 95%: 0,628; 0,76). Na análise de concordância de Bland-Altman, os limites de concordância foram de −17,0 (intervalo de confiança de 95%: −19,0; −15,0) e 32,0 (intervalo de confiança de 95%: 30,0; 34,0). A área sob a curva ROC foi de 0,896 (intervalo de confiança de 95%: 0,865; 0,923). CONCLUSÃO: A FC do ECG mostrou alta concordância com a FC do Holter, validando seu uso clínico em pacientes com ICFEr e ritmo sinusal. Contudo, a concordância foi subótima em um terço dos pacientes com FC inferior a 70 bpm pelo ECG, devendo ser considerada a realização de Holter neste contexto.


Asunto(s)
Electrocardiografía Ambulatoria , Insuficiencia Cardíaca , Frecuencia Cardíaca , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Electrocardiografía Ambulatoria/métodos , Femenino , Masculino , Frecuencia Cardíaca/fisiología , Volumen Sistólico/fisiología , Anciano , Persona de Mediana Edad , Estudios Transversales , Reproducibilidad de los Resultados , Electrocardiografía/métodos , Curva ROC , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA