Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Br J Clin Pharmacol ; 83(4): 742-750, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27792836

RESUMEN

AIM: No randomized study has been conducted to investigate the use of intravenous paracetamol (acetaminophen, APAP) for the management of fever due to infection. The present study evaluated a new ready-made infusion of paracetamol. METHODS: Eighty patients with a body temperature onset ≥38.5°C in the previous 24 h due to infection were randomized to a single administration of placebo (n = 39) or 1 g paracetamol (n = 41), and their temperature was recorded at standard intervals. Rescue medication with 1 g paracetamol was allowed. Serum samples were collected for the measurement of APAP and its metabolites. The primary endpoint was defervescence, defined as a core temperature ≤37.1°C. RESULTS: During the first 6 h, defervescence was achieved in 15 (38.5%) patients treated with placebo compared with 33 (80.5%) patients treated with paracetamol 1 g (P < 0.0001). The median time to defervescence with paracetamol 1 g was 3 h. Rescue medication was given to 15 (38.5%) and five (12.2%) patients allocated to placebo and paracetamol, respectively (P = 0.007); nine (60.0%) and two (40.0%) of these patients, respectively, experienced defervescence. No further antipyretic medication was needed for patients becoming afebrile with rescue medication. Serum glucuronide-APAP concentrations were significantly greater in the serum of patients who did not experience defervescence with paracetamol. The efficacy of paracetamol was not affected by serum creatinine. No drug-related adverse events were reported. CONCLUSIONS: The 1 g paracetamol formulation has a rapid and sustainable antipyretic effect on fever due to infection. Its efficacy is dependent on hepatic metabolism.


Asunto(s)
Acetaminofén/administración & dosificación , Antipiréticos/administración & dosificación , Fiebre/tratamiento farmacológico , Infecciones/complicaciones , Acetaminofén/farmacocinética , Acetaminofén/uso terapéutico , Administración Intravenosa , Adulto , Anciano , Antipiréticos/farmacocinética , Antipiréticos/uso terapéutico , Método Doble Ciego , Femenino , Fiebre/etiología , Estudios de Seguimiento , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento
2.
J AOAC Int ; 94(3): 758-64, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21797003

RESUMEN

An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cilazapril/análogos & derivados , Cilazapril/química , Espectrometría de Masas en Tándem/métodos , Equivalencia Terapéutica , Inhibidores de la Enzima Convertidora de Angiotensina/química , Inhibidores de la Enzima Convertidora de Angiotensina/farmacocinética , Automatización , Cilazapril/administración & dosificación , Cilazapril/farmacocinética , Estabilidad de Medicamentos , Humanos , Estructura Molecular , Sensibilidad y Especificidad , Manejo de Especímenes/métodos
3.
J Inherit Metab Dis ; 33 Suppl 3: S341-8, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20721692

RESUMEN

In Greece, the National Newborn Screening Program was initiated in 1974 and is performed by the Institute of Child Health (ICH). However, there is a complete absence of conditions that have high rates of mortality and a relatively high prevalence listed in the Catalogue of Disorders screened by the ICH. Our laboratory has expanded the existing NBS program to include newborn screening for inborn errors of metabolism, screening for cystic fibrosis (the most common congenital disorder in the Greek population), congenital adrenal hyperplasia, and for biotinidase deficiency. From July 2007 to December 2009, 45,000 dried blood spots (DBS) were collected from infants born in Athens, Greece, and were analyzed. We present a report of our 30-month experience in the newborn screening area. The samples were tested for amino acidopathies, fatty acid oxidation disorders (FAOD), and organic acid metabolic disorders by applying flow injection analysis-electrospray ionization-tandem mass spectrometry (FIA-ESI-MS/MS); for cystic fibrosis by immunoreactive trypsinogen (IRT) measurement (time-resolved fluoroimmunoassay); for congenital adrenal hyperplasia by fluoroimmunoassay to measure the 17 hydroxy-progesterone level; and for biotinidase deficiency using a colorimetric method and a semiquantitative fluoroimmunoassay to determine biotinidase activity. Sample analysis resulted in establishing cutoff values for the respective disease markers for the first time in the Greek population. Four infants were identified with cystic fibrosis, two with congenital adrenal hyperplasia, two with phenylketonuria (PKU), one with medium-chain acyl CoA dehydrogenase deficiency (MCADD), and one with biotinidase deficiency. To the best of our knowledge, this is the first article reporting the status of expanded newborn screening in Greece.


Asunto(s)
Errores Innatos del Metabolismo/diagnóstico , Tamizaje Neonatal , Biomarcadores/sangre , Colorimetría , Pruebas con Sangre Seca , Fluoroinmunoensayo , Grecia/epidemiología , Humanos , Recién Nacido , Errores Innatos del Metabolismo/sangre , Errores Innatos del Metabolismo/epidemiología , Errores Innatos del Metabolismo/terapia , Tamizaje Neonatal/métodos , Valor Predictivo de las Pruebas , Pronóstico , Desarrollo de Programa , Evaluación de Programas y Proyectos de Salud , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Factores de Tiempo
4.
J Pharm Biomed Anal ; 46(4): 771-9, 2008 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-18201852

RESUMEN

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of simvastatin (SV) and simvastatin acid (SVA) in human plasma. Plasma samples were treated by acetonitrile (ACN) addition for protein precipitation (PP) and subsequent two-step liquid-liquid extraction (LLE) in 96-deepwell plates, using methyl t-butyl ether (MTBE) as the organic solvent. ACN addition step was proven to enhance method sensitivity, as well as producing cleaner samples for injection. Lovastatin (LV) and lovastatin acid (LVA) were used as internal standards (IS) for SV and SVA quantification respectively. A relatively small plasma volume (300 microL) was employed and all procedure liquid transfer steps were performed automatically, by the use of robotic liquid handling workstations. Both electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources were applied and compared for LC-MS/MS sample analysis, with ESI proven to be more sensitive for the specific analytes. Polarity switch (from negative to positive ionization mode) was performed during the same analytical run, so as for the simultaneous SV and SVA determination to be possible. The method had a short sample preparation time, as well as a chromatographic run time of just 1.9 min, the shortest so far reported for SV determination. It was validated and fulfilled all preset criteria for sensitivity, specificity, linearity (0.100-40.0 ng/mL), inter- and intra-accuracy and precision for both molecules. The proposed method was applied to the rapid and reliable simultaneous determination of SV and SVA in a bioequivalence study, after per os administration of a SV tablet (80 mg).


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Simvastatina/análogos & derivados , Simvastatina/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Estabilidad de Medicamentos , Humanos , Simvastatina/farmacocinética
5.
J Pharm Biomed Anal ; 43(3): 1151-5, 2007 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-17045443

RESUMEN

In the current study, a semi-automated, 96-well format, solid-phase extraction (SPE), analytical column-switching method for alendronate determination in human urine is developed, validated and applied to a bioequivalence study. The current protocol was a substantial improvement of an existing classical method. A robotic liquid handling system was employed to simplify and reduce the time of sample preparation procedure. Automated SPE was carried out using a 96-well cartridge plate and a vacuum control system. Urine samples were determined by applying a column-switching protocol with fluorescence detection. Analysis time, due to the column-switching procedure, was about half of the conventional LC approach (11.5 min instead of 21 min). The method application required the determination of alendronate in urine samples obtained from 96 healthy volunteers as part of a bioequivalence study of two 70 mg alendronate sodium tablets. All major pharmacokinetic parameters of the bioequivalence study were estimated and reported.


Asunto(s)
Alendronato/orina , Conservadores de la Densidad Ósea/orina , Alendronato/farmacocinética , Autoanálisis , Conservadores de la Densidad Ósea/farmacocinética , Calibración , Química Farmacéutica , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Masculino , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrometría de Fluorescencia , Equivalencia Terapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA