Point-of-care diagnostic devices typically require six distinct qualities: they must deliver at least the same sensitivity and selectivity, and for a cost per assay no greater than that of today's central lab technologies, deliver results in a short period of time (ã15 min at GP; ã2h in hospital), be portable or at least small in scale, and require no or extremely little sample preparation. State-of-the-art devices deliver information of several markers in the same measurement.
Asunto(s)
Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Sistemas de Atención de Punto , Biomarcadores/análisis , ADN Bacteriano/aislamiento & purificación , Humanos , Técnicas Microbiológicas/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Sensibilidad y Especificidad , Detección de Abuso de Sustancias , Transductores , Virus/aislamiento & purificaciónRESUMEN
We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 x 10(-6) refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm(-2), to our knowledge the best reported values for integrated planar ring resonators.
RESUMEN
We demonstrate label-free molecule detection by using an integrated biosensor based on a Si(3)N(4)/SiO(2) slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2 nm/(ng/mm(2)) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16 pg/mm(2) for anti-BSA and BSA, respectively, limited by wavelength resolution.
Asunto(s)
Técnicas Biosensibles/instrumentación , Óptica y Fotónica , Albúmina Sérica Bovina/química , Animales , Técnicas Biosensibles/métodos , Bovinos , Técnicas de Química Analítica/métodos , Diseño de Equipo , Rayos Láser , Sensibilidad y Especificidad , Espectrofotometría/métodosRESUMEN
We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguide microring resonator. The microresonator is fabricated on a Si3N4-SiO2 platform and operates at a wavelength of 1.3 microm. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n=1.33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2x10(-4) RIU.
Asunto(s)
Técnicas Biosensibles/instrumentación , Óptica y Fotónica/instrumentación , Refractometría/instrumentación , Técnicas Biosensibles/métodos , Refractometría/métodosRESUMEN
We report on the first demonstration of guiding light in vertical slot-waveguides on silicon nitride/silicon oxide material system. Integrated ring resonators and Fabry-Perot cavities have been fabricated and characterized in order to determine optical features of the slot-waveguides. Group index behavior evidences guiding and confinement in the low-index slot region at O-band (1260-1370nm) telecommunication wavelengths. Propagation losses of <20 dB/cm have been measured for the transverse-electric mode of the slot-waveguides.