Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cardiovasc Eng Technol ; 11(1): 59-66, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31741174

RESUMEN

BACKGROUND: Transcatheter aortic valve implants (TAVI) have revolutionised the treatment of elderly patients requiring aortic valve replacement. These patients often do not tolerate balloon valvuloplasty well, and a valvuloplasty balloon that would allow a degree of continued cardiac output during expansion would be beneficial. We tested such a balloon and describe our results in the sheep model. METHODS AND RESULTS: We developed a non-occlusive balloon (NOB) catheter. An acute experiment was performed where the NOB was inflated in six sheep in the aortic valve position without any attempt to arrest cardiac output. Two inflations were performed per animal: the first for 30 s and the second for 2-3 min. Standard occlusive balloons were inflated in two animals under rapid ventricular pacing to serve as controls. Mean pressure gradient across the NOB was 9.7 ± 5 mmHg during the inflations and all animals remained hemodynamically stable during NOB inflations. CONCLUSIONS: The novel non-occlusive balloon catheter, which permitted uninterrupted cardiac output for a prolonged period without the need for pacing-induced temporary cessation of cardiac output, is both feasible and well tolerated in the acute sheep model.


Asunto(s)
Válvula Aórtica , Valvuloplastia con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Gasto Cardíaco , Diseño de Equipo , Ensayo de Materiales , Modelos Animales , Presión , Prueba de Estudio Conceptual , Oveja Doméstica , Factores de Tiempo
2.
Echo Res Pract ; 4(2): 9-19, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28490455

RESUMEN

AIMS: Lupus myocarditis occurs in 5-10% of patients with systemic lupus erythematosus (SLE). No single feature is diagnostic of lupus myocarditis. Speckle tracking echocardiography (STE) can detect subclinical left ventricular dysfunction in SLE patients, with limited research on its utility in clinical lupus myocarditis. We report on STE in comparison to conventional echocardiography in patients with clinical lupus myocarditis. METHODS AND RESULTS: A retrospective study was done at a tertiary referral hospital in South Africa. SLE patients with lupus myocarditis were included and compared to healthy controls. Echocardiographic images were reanalyzed, including global longitudinal strain through STE. A poor echocardiographic outcome was defined as final left ventricular ejection fraction (LVEF) <40%. 28 SLE patients fulfilled the criteria. Global longitudinal strain correlated with global (LVEF: r = -0.808; P = 0.001) and regional (wall motion score: r = 0.715; P < 0.001) function. In patients presenting with a LVEF ≥50%, global longitudinal strain (P = 0.023), wall motion score (P = 0.005) and diastolic function (P = 0.004) were significantly impaired vs controls. Following treatment, LVEF (35-47% (P = 0.023)) and wall motion score (1.88-1.5 (P = 0.017)) improved but not global longitudinal strain. Initial LVEF (34%; P = 0.046) and global longitudinal strain (-9.5%; P = 0.095) were lower in patients with a final LVEF <40%. CONCLUSIONS: This is the first known report on STE in a series of patients with clinical lupus myocarditis. Global longitudinal strain correlated with regional and global left ventricular function. Global longitudinal strain, wall motion score and diastolic parameters may be more sensitive markers of lupus myocarditis in patients presenting with a preserved LVEF ≥50%. A poor initial LVEF and global longitudinal strain were associated with a persistent LVEF <40%. Echocardiography is a non-invasive tool with diagnostic and prognostic value in lupus myocarditis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA