Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artif Organs ; 48(9): 977-987, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38651352

RESUMEN

BACKGROUND: In vitro assessment is mandatory for artificial heart valve development. This study aims to investigate the effects of pulse duplicator features on valve responsiveness, conduct a sensitivity analysis across valve prosthesis types, and contribute on the development of versatile pulse duplicator systems able to perform reliable prosthetic aortic valve assessment under physiologic hemodynamic conditions. METHODS: A reference pulse duplicator was established based on literature. Further optimization process led to new designs that underwent a parametric study, also involving different aortic valve prostheses. These designs were evaluated on criteria such as mean pressure differential and pulse pressure (assessed from high-fidelity pressure measurements), valve opening and closing behavior, flow, and regurgitation. Finally, the resulting optimized setup was tested under five different hemodynamic settings simulating a range of physiologic and pathologic conditions. RESULTS: The results show that both, pulse duplicator design and valve type significantly influence aortic and ventricular pressure, flow, and valve kinematic response. The optimal design comprised key features such as a compliance chamber and restrictor for diastolic pressure maintenance and narrow pulse pressure. Additionally, an atrial reservoir was included to prevent atrial-aortic interference, and a bioprosthetic valve was used in mitral position to avoid delayed valve closing effects. CONCLUSION: This study showed that individual pulse duplicator features can have a significant effect on valve's responsiveness. The optimized versatile pulse duplicator replicated physiologic and pathologic aortic valve hemodynamic conditions, serving as a reliable characterization tool for assessing and optimizing aortic valve performance.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Humanos , Válvula Aórtica/cirugía , Modelos Cardiovasculares , Bioprótesis
2.
iScience ; 25(10): 105157, 2022 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-36185369

RESUMEN

In this backstory, researchers from Swiss Federal Institute of Technology (ETH Zurich) who initiated an interdisciplinary program to generate innovative solutions for different cardiovascular diseases, such as myocardial infarction, valvular replacement, and movement-based rehabilitation therapy, discuss the benefits and challenges of interdisciplinary research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA