Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Musculoskelet Surg ; 107(3): 351-359, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36648636

RESUMEN

INTRODUCTION: The proximal humerus is a frequent site for both primary and secondary bone tumors. Several options are currently available to reconstruct the resected humerus, but there is no consensus regarding optimal reconstruction. The aim of this retrospective study was to compare the functional outcome, complications and patient compliance following four different types of reconstructive techniques. MATERIAL AND METHODS: The authors performed 90 proximal humerus resections due to primary and secondary bone tumors over the past 21 years. Four different procedures were performed for reconstruction following the resection: fibula autograft transplantation, osteoarticular allograft implantation, modular tumor endoprosthesis (hemiarthroplasty) and reconstruction of the defect with a reverse shoulder prosthesis-allograft composite. A retrospective analysis of the complications and patient's physical status was performed. Functional outcome and life quality was evaluated by using the MSTS and SF-36 scores. RESULTS: The best range of motion was observed following arthroplasty with a reverse shoulder prosthesis-homograft composite followed by a fibula autograft reconstruction. Revision surgery was required due to major complications most frequently in the osteoarticular allograft group, followed by the reverse shoulder prosthesis-allograft composite group, the autologous fibula transplantation group; the tumor endoprosthesis hemiarthroplasty group had superior results regarding revision surgery (40, 25, 24 and 14% respectively). MSTS was 84% on average for the reverse shoulder prosthesis-allograft composite group, 70% for the autologous fibula group, 67% for the anatomical hemiarthroplasty group and 64% for the osteoartricular allograft group. Using the SF-36 questionnaire for assessment no significant differences were found between the four groups regarding quality of life. DISCUSSION: Based on the results of our study the best functional performance (range of motion and patient compliance) was achieved in the a reverse prosthesis-allograft combination group-in cases where the axillary nerve could be spared. The use of an osteoarticular allograft resulted in unsatisfying functional results and high complication rates, therefore we do not recommend it as a reconstructive method following resection of the proximal humerus due to either primary or metastatic bone tumors. Young patients who have good life expectancy but a small humerus or intramedullar cavity reconstruction by implantation of a fibula autograft is a good option. For patients with a poor prognosis (i.g. bone metastases) or in cases where the axillary nerve must be sacrificed, hemiarthroplasty using a tumor endoprosthesis was found to have acceptable results with a low complication rate. According to the MSTS and SF-36 functional scoring systems patients compliance was nearly identical following all four types of reconstruction techniques; the underlying cause may be the complexity of the shoulder girdle. However, we recommend the implantation of a reverse shoulder prosthesis-allograft whenever indication is appropriate, as it has been demonstrated to provide excellent functional outcomes, especially in young adults.


Asunto(s)
Neoplasias Óseas , Prótesis Articulares , Articulación del Hombro , Adulto Joven , Humanos , Hombro/patología , Estudios Retrospectivos , Calidad de Vida , Húmero/cirugía , Articulación del Hombro/patología , Neoplasias Óseas/cirugía , Resultado del Tratamiento
2.
Int Orthop ; 29(3): 174-8, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15830238

RESUMEN

Between 1993 and 2002, we treated 43 patients with malignant musculoskeletal tumours of the knee region. All patients had partial resection of the femur or tibia together with endoprosthetic replacement. We were able to follow-up 23 patients with an average follow-up of 30 (12-97) months. Complications occurred in ten cases, of which one was a case of local recurrence. Most of the patients were completely satisfied with their condition, with a decreased walking distance as the only notable restriction. There was no correlation between the functional outcome and life quality assessment and the type of the implanted prosthesis, length of resected bone and type of resection. However, patients with tumours in the distal femur had significantly better functional and life quality outcome than those with a proximal tibial tumour.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Neoplasias Óseas/cirugía , Carcinoma/cirugía , Fémur , Sarcoma/cirugía , Tibia , Adulto , Neoplasias Óseas/patología , Neoplasias Óseas/secundario , Carcinoma/secundario , Femenino , Humanos , Masculino , Calidad de Vida , Recuperación de la Función , Sarcoma/patología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA