Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Mol Cell Probes ; 30(2): 74-8, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26854117

RESUMEN

Recombinase Polymerase Amplification (RPA) can be used to detect pathogen-specific DNA or RNA in under 20 min without the need for complex instrumentation. These properties enable its potential use in resource limited settings. However, there are concerns that deviations from the manufacturer's protocol and/or storage conditions could influence its performance in low resource settings. RPA amplification relies upon viscous crowding agents for optimal nucleic acid amplification, and thus an interval mixing step after 3-6 min of incubation is recommended to distribute amplicons and improve performance. In this study we used a HIV-1 RPA assay to evaluate the effects of this mixing step on assay performance. A lack of mixing led to a longer time to amplification and inferior detection signal, compromising the sensitivity of the assay. However lowering the assay volume from 50 µL to 5 µL showed similar sensitivity with or without mixing. We present the first peer-reviewed study that assesses long term stability of RPA reagents without a cold chain. Reagents stored at -20 °C, and 25 °C for up to 12 weeks were able to detect 10 HIV-1 DNA copies. Reagents stored at 45 °C for up to 3 weeks were able to detect 10 HIV-1 DNA copies, with reduced sensitivity only after >3 weeks at 45 °C. Together our results show that reducing reaction volumes bypassed the need for the mixing step and that RPA reagents were stable even when stored for 3 weeks at very high temperatures.


Asunto(s)
VIH-1/genética , ARN Viral/genética , Recombinasas/metabolismo , Humanos , Técnicas de Amplificación de Ácido Nucleico , Sistemas de Atención de Punto , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Recombinasas/genética , Sensibilidad y Especificidad
2.
J Virol Methods ; 230: 28-35, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26821087

RESUMEN

A low complexity diagnostic test that rapidly and reliably detects HIV infection in infants at the point of care could facilitate early treatment, improving outcomes. However, many infant HIV diagnostics can only be performed in laboratory settings. Recombinase polymerase amplification (RPA) is an isothermal amplification technology that can rapidly amplify proviral DNA from multiple subtypes of HIV-1 in under twenty minutes without complex equipment. In this study we added reverse transcription (RT) to RPA to allow detection of both HIV-1 RNA and DNA. We show that this RT-RPA HIV-1 assay has a limit of detection of 10-30 copies of an exact sequence matched DNA or RNA, respectively. In addition, at 100 copies of RNA or DNA, the assay detected 171 of 175 (97.7%) sequence variants that represent all the major subtypes and recombinant forms of HIV-1 Groups M and O. This data suggests that the application of RT-RPA for the combined detection of HIV-1 viral RNA and proviral DNA may prove a highly sensitive tool for rapid and accurate diagnosis of infant HIV.


Asunto(s)
Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , VIH-1/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico/métodos , Humanos , Lactante , Técnicas de Diagnóstico Molecular , Recombinasas/análisis , Recombinasas/genética , Transcripción Reversa , Sensibilidad y Especificidad , Proteínas Virales/análisis , Proteínas Virales/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA