Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Orphanet J Rare Dis ; 19(1): 373, 2024 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-39390597

RESUMEN

BACKGROUND: Fabry disease (FD) is a rare X-linked lysosomal storage disorder marked by alpha-galactosidase-A (α-Gal A) deficiency, caused by pathogenic mutations in the GLA gene, resulting in the accumulation of glycosphingolipids within lysosomes. The current screening test relies on measuring α-Gal A activity. However, this approach is limited to males. Infrared (IR) spectroscopy is a technique that can generate fingerprint spectra of a biofluid's molecular composition and has been successfully applied to screen numerous diseases. Herein, we investigate the discriminating vibration profile of plasma chemical bonds in patients with FD using attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy. RESULTS: The Fabry disease group (n = 47) and the healthy control group (n = 52) recruited were age-matched (39.2 ± 16.9 and 36.7 ± 10.9 years, respectively), and females were predominant in both groups (59.6% and 65.4%, respectively). All patients had the classic phenotype (100%), and no late-onset phenotype was detected. A generated partial least squares discriminant analysis (PLS-DA) classification model, independent of gender, allowed differentiation of samples from FD vs. control groups, reaching 100% sensitivity, specificity and accuracy. CONCLUSION: ATR-FTIR spectroscopy harnessed to pattern recognition algorithms can distinguish between FD patients and healthy control participants, offering the potential of a fast and inexpensive screening test.


Asunto(s)
Enfermedad de Fabry , Enfermedad de Fabry/diagnóstico , Humanos , Masculino , Femenino , Adulto , Proyectos Piloto , Persona de Mediana Edad , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Adulto Joven , Espectrofotometría Infrarroja/métodos , alfa-Galactosidasa/genética
2.
Analyst ; 149(19): 4851-4861, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39105622

RESUMEN

Lung cancer is one of the most commonly occurring malignant tumours worldwide. Although some reference methods such as X-ray, computed tomography or bronchoscope are widely used for clinical diagnosis of lung cancer, there is still a need to develop new methods for early detection of lung cancer. Especially needed are approaches that might be non-invasive and fast with high analytical precision and statistically reliable. Herein, we developed a swab "dip" test in saliva whereby swabs were analysed using attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy harnessed to principal component analysis-quadratic discriminant analysis (QDA) and variable selection techniques employing successive projections algorithm (SPA) and genetic algorithm (GA) for feature selection/extraction combined with QDA. A total of 1944 saliva samples (56 designated as lung-cancer positive and 1888 designed as controls) were obtained in a lung cancer-screening programme being undertaken in North-West England. GA-QDA models achieved, for the test set, sensitivity and specificity values of 100.0% and 99.1%, respectively. Three wavenumbers (1422 cm-1, 1546 cm-1 and 1578 cm-1) were identified using the GA-QDA model to distinguish between lung cancer and controls, including ring C-C stretching, CN adenine, Amide II [δ(NH), ν(CN)] and νs(COO-) (polysaccharides, pectin). These findings highlight the potential of using biospectroscopy associated with multivariate classification algorithms to discriminate between benign saliva samples and those with underlying lung cancer.


Asunto(s)
Neoplasias Pulmonares , Análisis de Componente Principal , Saliva , Humanos , Saliva/química , Neoplasias Pulmonares/diagnóstico , Análisis Discriminante , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Algoritmos , Masculino , Femenino , Persona de Mediana Edad , Anciano
3.
Talanta ; 269: 125482, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38042146

RESUMEN

Attenuated Total Reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy is an emerging technology in the medical field. Blood D-dimer was initially studied as a marker of the activation of coagulation and fibrinolysis. It is mainly used as a potential diagnosis screening test for pulmonary embolism or deep vein thrombosis but was recently associated with COVID-19 severity. This study aimed to evaluate the use of ATR-FTIR spectroscopy with machine learning to classify plasma D-dimer concentrations. The plasma ATR-FTIR spectra from 100 patients were studied through principal component analysis (PCA) and two supervised approaches: genetic algorithm with linear discriminant analysis (GA-LDA) and partial least squares with linear discriminant (PLS-DA). The spectra were truncated to the fingerprint region (1800-1000 cm-1). The GA-LDA method effectively classified patients according to D-dimer cutoff (≤0.5 µg/mL and >0.5 µg/mL) with 87.5 % specificity and 100 % sensitivity on the training set, and 85.7 % specificity, and 95.6 % sensitivity on the test set. Thus, we demonstrate that ATR-FTIR spectroscopy might be an important additional tool for classifying patients according to D-dimer values. ATR-FTIR spectral analyses associated with clinical evidence can contribute to a faster and more accurate medical diagnosis, reduce patient morbidity, and save resources and demand for professionals.


Asunto(s)
Espectroscopía Infrarroja por Transformada de Fourier , Humanos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Análisis de Fourier , Análisis Discriminante , Análisis de Componente Principal , Proteínas de la Ataxia Telangiectasia Mutada
4.
J Pers Med ; 14(1)2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38276224

RESUMEN

The use of non-invasive tools in conjunction with artificial intelligence (AI) to detect diseases has the potential to revolutionize healthcare. Near-infrared spectroscopy (NIR) is a technology that can be used to analyze biological samples in a non-invasive manner. This study evaluated the use of NIR spectroscopy in the fingertip to detect neutropenia in solid-tumor oncologic patients. A total of 75 patients were enrolled in the study. Fingertip NIR spectra and complete blood counts were collected from each patient. The NIR spectra were pre-processed using Savitzky-Golay smoothing and outlier detection. The pre-processed data were split into training/validation and test sets using the Kennard-Stone method. A toolbox of supervised machine learning classification algorithms was applied to the training/validation set using a stratified 5-fold cross-validation regimen. The algorithms included linear discriminant analysis (LDA), logistic regression (LR), random forest (RF), multilayer perceptron (MLP), and support vector machines (SVMs). The SVM model performed best in the validation step, with 85% sensitivity, 89% negative predictive value (NPV), and 64% accuracy. The SVM model showed 67% sensitivity, 82% NPV, and 57% accuracy on the test set. These results suggest that NIR spectroscopy in the fingertip, combined with machine learning methods, can be used to detect neutropenia in solid-tumor oncology patients in a non-invasive and timely manner. This approach could help reduce exposure to invasive tests and prevent neutropenic patients from inadvertently undergoing chemotherapy.

5.
J Proteome Res ; 21(8): 1868-1875, 2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35880262

RESUMEN

Rapid identification of existing respiratory viruses in biological samples is of utmost importance in strategies to combat pandemics. Inputting MALDI FT-ICR MS (matrix-assisted laser desorption/ionization Fourier-transform ion cyclotron resonance mass spectrometry) data output into machine learning algorithms could hold promise in classifying positive samples for SARS-CoV-2. This study aimed to develop a fast and effective methodology to perform saliva-based screening of patients with suspected COVID-19, using the MALDI FT-ICR MS technique with a support vector machine (SVM). In the method optimization, the best sample preparation was obtained with the digestion of saliva in 10 µL of trypsin for 2 h and the MALDI analysis, which presented a satisfactory resolution for the analysis with 1 M. SVM models were created with data from the analysis of 97 samples that were designated as SARS-CoV-2 positives versus 52 negatives, confirmed by RT-PCR tests. SVM1 and SVM2 models showed the best results. The calibration group obtained 100% accuracy, and the test group 95.6% (SVM1) and 86.7% (SVM2). SVM1 selected 780 variables and has a false negative rate (FNR) of 0%, while SVM2 selected only two variables with a FNR of 3%. The proposed methodology suggests a promising tool to aid screening for COVID-19.


Asunto(s)
COVID-19 , COVID-19/diagnóstico , Prueba de COVID-19 , Análisis de Fourier , Humanos , Aprendizaje Automático , SARS-CoV-2 , Saliva , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
6.
Anal Chem ; 93(5): 2950-2958, 2021 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-33481583

RESUMEN

There is an urgent need for ultrarapid testing regimens to detect the severe acute respiratory syndrome coronavirus 2 [SARS-CoV-2] infections in real-time within seconds to stop its spread. Current testing approaches for this RNA virus focus primarily on diagnosis by RT-qPCR, which is time-consuming, costly, often inaccurate, and impractical for general population rollout due to the need for laboratory processing. The latency until the test result arrives with the patient has led to further virus spread. Furthermore, latest antigen rapid tests still require 15-30 min processing time and are challenging to handle. Despite increased polymerase chain reaction (PCR)-test and antigen-test efforts, the pandemic continues to evolve worldwide. Herein, we developed a superfast, reagent-free, and nondestructive approach of attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy with subsequent chemometric analysis toward the prescreening of virus-infected samples. Contrived saliva samples spiked with inactivated γ-irradiated COVID-19 virus particles at levels down to 1582 copies/mL generated infrared (IR) spectra with a good signal-to-noise ratio. Predominant virus spectral peaks are tentatively associated with nucleic acid bands, including RNA. At low copy numbers, the presence of a virus particle was found to be capable of modifying the IR spectral signature of saliva, again with discriminating wavenumbers primarily associated with RNA. Discrimination was also achievable following ATR-FTIR spectral analysis of swabs immersed in saliva variously spiked with virus. Next, we nested our test system in a clinical setting wherein participants were recruited to provide demographic details, symptoms, parallel RT-qPCR testing, and the acquisition of pharyngeal swabs for ATR-FTIR spectral analysis. Initial categorization of swab samples into negative versus positive COVID-19 infection was based on symptoms and PCR results (n = 111 negatives and 70 positives). Following training and validation (using n = 61 negatives and 20 positives) of a genetic algorithm-linear discriminant analysis (GA-LDA) algorithm, a blind sensitivity of 95% and specificity of 89% was achieved. This prompt approach generates results within 2 min and is applicable in areas with increased people traffic that require sudden test results such as airports, events, or gate controls.


Asunto(s)
Algoritmos , COVID-19/diagnóstico , SARS-CoV-2/fisiología , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Virión/química , COVID-19/virología , Análisis Discriminante , Rayos gamma , Humanos , Pruebas en el Punto de Atención , Análisis de Componente Principal , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Sensibilidad y Especificidad , Relación Señal-Ruido , Virión/efectos de la radiación , Inactivación de Virus
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA