Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Acta Cir Bras ; 22(3): 229-33, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17546297

RESUMEN

PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.


Asunto(s)
Anestesia por Inhalación/veterinaria , Anestésicos por Inhalación/administración & dosificación , Anestesia por Inhalación/instrumentación , Anestesia por Inhalación/normas , Animales , Animales de Laboratorio/cirugía , Diseño de Equipo , Ratas , Ratas Wistar
2.
Acta cir. bras ; Acta cir. bras;22(3): 229-233, May-June 2007. tab, ilus
Artículo en Inglés | LILACS | ID: lil-452206

RESUMEN

PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.


OBJETIVOS: As dificuldades evidenciadas no uso de vaporizadores para anestesia em animais de pequeno porte motivaram o aperfeiçoamento e a criação de novos componentes técnicos visando a construção de um aparelho de anestesia de baixo custo, prático e versátil no manuseio e que atenda aos preceitos éticos do ensino e da pesquisa. MÉTODOS: Utilizaram-se 30 ratos da linhagem Wistar, Rattus norvegicus albinus, distribuídos em três grupos. Grupo 1,2 e 3 (n=10, cada), compreenderam o uso do novo aparelho aduzido, respectivamente, do Éter; Halotano e Sevoflurano. Foram verificados o tempo de indução anestésica, as alterações do ritmo ventilatório durante o tempo de manutenção anestésica (pré-estabelecido em 10 min) e o tempo de recuperação anestésica. O aparelho foi construído com dispositivos técnicos novos sobressaindo: o vaporizador, a válvula unidirecional na campânula, o cilindro de vidro com água, o tubo direcionador de fluxo em forma de Y, os reguladores de fluxo, as modificações na máscara e a entrada de ar, independente, para situações emergenciais. RESULTADOS: O aparelho permitiu um fácil manuseio e propiciou uma maior segurança e estabilidade na indução e manutenção anestésicas possibilitando, inclusive, a utilização de vários agentes anestésicos. CONCLUSÃO: O aparelho demonstrou ser útil para anestesia em cirurgia experimental, facilitando a realização dos procedimentos de pesquisa e de ensino de forma mais prática, eficiente, segura, e com baixo custo.


Asunto(s)
Animales , Ratas , Anestesia por Inhalación/veterinaria , Anestésicos por Inhalación/administración & dosificación , Anestesia por Inhalación/instrumentación , Anestesia por Inhalación/normas , Animales de Laboratorio/cirugía , Diseño de Equipo , Ratas Wistar
3.
Acta cir. bras. ; 22(3): 229-233, May-June 2007. tab, ilus
Artículo en Inglés | VETINDEX | ID: vti-2262

RESUMEN

PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.(AU)


OBJETIVOS: As dificuldades evidenciadas no uso de vaporizadores para anestesia em animais de pequeno porte motivaram o aperfeiçoamento e a criação de novos componentes técnicos visando a construção de um aparelho de anestesia de baixo custo, prático e versátil no manuseio e que atenda aos preceitos éticos do ensino e da pesquisa. MÉTODOS: Utilizaram-se 30 ratos da linhagem Wistar, Rattus norvegicus albinus, distribuídos em três grupos. Grupo 1,2 e 3 (n=10, cada), compreenderam o uso do novo aparelho aduzido, respectivamente, do Éter; Halotano e Sevoflurano. Foram verificados o tempo de indução anestésica, as alterações do ritmo ventilatório durante o tempo de manutenção anestésica (pré-estabelecido em 10 min) e o tempo de recuperação anestésica. O aparelho foi construído com dispositivos técnicos novos sobressaindo: o vaporizador, a válvula unidirecional na campânula, o cilindro de vidro com água, o tubo direcionador de fluxo em forma de Y, os reguladores de fluxo, as modificações na máscara e a entrada de ar, independente, para situações emergenciais. RESULTADOS: O aparelho permitiu um fácil manuseio e propiciou uma maior segurança e estabilidade na indução e manutenção anestésicas possibilitando, inclusive, a utilização de vários agentes anestésicos. CONCLUSÃO: O aparelho demonstrou ser útil para anestesia em cirurgia experimental, facilitando a realização dos procedimentos de pesquisa e de ensino de forma mais prática, eficiente, segura, e com baixo custo.(AU)


Asunto(s)
Animales , Anestesia por Inhalación/economía , Anestesia por Inhalación/métodos , Nebulizadores y Vaporizadores , Desarrollo Experimental , Ratas Wistar
4.
J. vasc. bras ; 5(4): 257-262, dez. 2006. tab
Artículo en Portugués | LILACS | ID: lil-448040

RESUMEN

OBJETIVO: Analisar comparativamente os resultados, em 30 dias, entre a endarterectomia e a angioplastia com stent auto-expansível e filtro de proteção cerebral, avaliando a incidência de acidente vascular cerebral e óbito, bem como o tempo de permanência hospitalar no tratamento das lesões ateroscleróticas da bifurcação carotídea. MÉTODO: Estudo prospectivo, em que foram tratados 80 pacientes, sintomáticos e assintomáticos, com lesões estenóticas maiores que 60 e 70 por cento, respectivamente, da bifurcação carotídea. Os pacientes foram divididos em dois grupos de 40 pacientes, que foram avaliados quanto a sexo, idade, comorbidades associadas e tabagismo. RESULTADOS: A taxa de acidente vascular cerebral e óbito foi de 5,0 por cento em ambas as técnicas. Ocorreu um caso (2,5 por cento) de ataque isquêmico transitório no grupo endovascular e nenhum na endarterectomia. No que se refere ao tempo de internação, o tratamento endovascular apresentou menor tempo em relação à endarterectomia, sendo estatisticamente significativo (P < 0,002). CONCLUSÕES: Nesta série apresentada, a incidência de acidente vascular cerebral e óbito em 30 dias foi de 5 por cento nas duas técnicas utilizadas. Em relação ao tempo de internação, houve um menor tempo de permanência hospitalar a favor da técnica endovascular, com significância estatística (P < 0,002).


OBJECTIVE: To comparatively analyze the 30-day results between endarterectomy and angioplasty using self-expandable stent and filter protection in the treatment of carotid bifurcation atherosclerotic lesions. The primary endpoint was to analyze stroke and death rate, as well hospitalization time. METHODS: Comparative and prospective study in 80 symptomatic and asymptomatic patients, with carotid bifurcation stenotic lesions greater than 60 and 70 percent, respectively. The patients were divided into two groups of 40 and assessed according to gender, age, associated comorbid conditions and smoking. RESULTS: The stroke and death rate was 5.0 percent for both techniques. There was only one case of transient ischemic attack (2.5 percent) in the endovascular group. Regarding hospitalization time, it was significantly lower in favor of the endovascular technique, with statistical significance (P < 0.002). CONCLUSIONS: This study demonstrated a 5.0 percent incidence of stroke and death in 30 days considering both techniques. However, the endovascular group presented a statistically significant shorter hospitalization time than the endarterectomy group (P < 0.002).


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Angioplastia/métodos , Angioplastia , Enfermedades de las Arterias Carótidas/complicaciones , Enfermedades de las Arterias Carótidas/diagnóstico , Endarterectomía/efectos adversos , Endarterectomía , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico , Stents
5.
Rev. Col. Bras. Cir ; 33(6): 413-415, nov.-dez. 2006. ilus
Artículo en Portugués | LILACS | ID: lil-442057

RESUMEN

Vascular complications after kidney transplantation have been described and pseudoaneurysms represent a well-recognized vascular complication. Although the incidence of pseudoaneurysm is low, it may potentially cause graft loss or may even be fatal for the patients if it is not diagnosed and treated quickly. The authors report a case of renal artery pseudoaneurysm diagnosed two months posttransplantation with cadaveric graft, the treatment and literature data.

6.
J. vasc. bras ; 5(3): 237-241, set. 2006. ilus
Artículo en Portugués | LILACS | ID: lil-447952

RESUMEN

Os autores relatam um caso de tumor de corpo carotídeo (paraganglioma) em um paciente de 74 anos de idade, submetido a embolização intra-arterial com micropartículas esféricas, de polivinil acetato, com casca de polivinil álcool (PVAc + PVA), previamente à ressecção do tumor. O estudo angiográfico demonstrou massa altamente vascularizada na bifurcação carotídea esquerda, sendo a embolização pré-operatória utilizada no intuito de diminuir a vascularização e reduzir a perda sangüínea, aumentando a segurança do tratamento cirúrgico. O estudo histopatológico confirmou a presença de trombose e isquemia tecidual.


The authors report a case of carotid body tumor (paraganglioma) in a 74-year-old male patient, submitted to intraarterial embolization with spherical core/shield polyvinyl acetate and polyvinyl alcohol (PVAc + PVA) microparticles prior to surgical excision. Angiography has demonstrated a highly vascularized mass in the left carotid bifurcation, and preoperative embolization was used in order to decrease vascularity, reduce blood loss and improve safety of surgical treatment. Microscopic study confirmed presence of thrombosis and tissue ischemia.


Asunto(s)
Masculino , Anciano , Humanos , Alcohol Polivinílico , Embolización Terapéutica/métodos , Embolización Terapéutica , Paraganglioma/cirugía , Paraganglioma/complicaciones , Paraganglioma/diagnóstico , Radiología Intervencionista/métodos , Radiología Intervencionista/normas , Tumor del Cuerpo Carotídeo/cirugía , Tumor del Cuerpo Carotídeo/complicaciones , Tumor del Cuerpo Carotídeo/diagnóstico
7.
Rev. Col. Bras. Cir ; 32(5): 237-243, set.-out. 2005. ilus, tab
Artículo en Portugués | LILACS | ID: lil-428687

RESUMEN

OBJETIVO: Relacionar a influência dos dois tipos de anastomoses arteriais empregadas (término-terminal e término-lateral), da idade do receptor, do rim de doador vivo ou cadáver e do uso de remendo aórtico ("patch") quanto à presença ou não de estenose da artéria renal e, avaliar o tratamento destas estenoses. MÉTODO: Estudo retrospectivo de 278 pacientes submetidos a transplante renal no Hospital Universitário Clementino Fraga Filho (HUCFF), de maio de 1989 a maio de 2001. RESULTADOS: Não se mostrou relação entre as variáveis estudadas com a presença ou não de estenose da artéria renal. A estenose da artéria renal foi detectada em oito casos, que foram tratados, com sucesso, mediante angioplastia transluminal percutânea (ATP), com implante primário de "stent" (n = 7) ou sem implante de "stent" (n = 1). CONCLUSÕES: As variáveis estudadas não influenciaram no aparecimento da estenose da artéria renal e o tratamento endovascular foi efetivo na correção destas lesões estenóticas.

8.
Rev. Col. Bras. Cir ; 32(1): 54-55, jan.-fev. 2005. ilus
Artículo en Portugués | LILACS | ID: lil-451123

RESUMEN

Abdominal aortic aneurysm reconstruction is usually performed in vascular surgical practice. However, the repair of an abdominal aortic aneurysm associated with a pelvic kidney is rare. Our goal is to present a case report of an abdominal aortic aneurysm associated with two congenital pelvic kidneys wich was treated successfully by aneurysmectomy and inclusion of an aortoaortic graft.

9.
Arq. neuropsiquiatr ; Arq. neuropsiquiatr;60(3B): 807-817, Sept. 2002. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-325499

RESUMEN

Diversos fatores têm sido associados ao desenvolvimento de edema peritumoral nos meningiomas. Foram estudados os aspectos radiológicos e anátomo-patológicos de 51 meningiomas intracranianos operados no Hospital Universitário Clementino Fraga Filho (HUCFF). Dois terços dos meningiomas apresentavam edema perilesional. O tamanho dos meningiomas correlacionou-se com a presença de edema, sendo mais frequente nos meningiomas grandes (>4cm). A localizaçäo parece, também, influenciar no desenvolvimento do edema peritumoral, sendo mais acentuado nos meningiomas da asa do esfenóide e incomum nos meningiomas do tubérculo selar. Os subtipos histológicos de meningioma näo se correlacionaram com a intensidade do edema peritumoral. Dos diversos mediadores químicos descritos na literatura recente relacionados ao desenvolvimento de edema peritumoral em tumores intracranianos, destaca-se o fator de crescimento do endotélio vascular (VEGF). A expressäo nos meningiomas do VEGF e de seu receptor flk-1 foi estudada com técnica imuno-histoquímica, demonstrando a sua expressäo nas células tumorais


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Biomarcadores de Tumor , Edema Encefálico , Neoplasias Encefálicas , Linfocinas , Meningioma , /análisis , Inmunohistoquímica , Modelos Lineales , Imagen por Resonancia Magnética , Meningioma , Estadísticas no Paramétricas , Tomografía Computarizada por Rayos X
10.
Rev. Col. Bras. Cir ; 26(1): 51-5, jan.-fev. 1999. ilus
Artículo en Portugués | LILACS | ID: lil-261072

RESUMEN

Foram analisados retrospectivamente dez pacientes portadores de aneurisma da artéria esplênica, submetidos a tratamento no Hospital Universitário Clementino Fraga Filho, no período compreendido entre outubro de 1978 a março de 1997. Perfaziam um total de 14 aneurismas da artéria esplênica, sendo únicos em nove pacientes e múltiplos (cinco) em um paciente. Houve predominância do sexo feminino com relação mulher/homem de 4/1. Foi realizado tratamento cirúrgico em 60 por cento dos pacientes, embolização dos aneurismas em 10 por cento, associação de embolização e cirurgia em 10 por cento e tratamento conservador em 20 por cento. Nenhum óbito ocorreu durante o tratamento


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Aneurisma , Arteria Esplénica
11.
J. bras. med ; 75(2): 41-2, 44, 46-8, ago. 1998. ilus
Artículo en Portugués | LILACS | ID: lil-252373

RESUMEN

A fístula aorto-entérica primária (FAEP) é uma entidade clínica extremamente rara, geralmente associada a doenças infecciosas prévias ou congênitas. Elas ocorrem predominantemente na terceira ou quarta porção do duodeno. A sintomatologia habitualmente consiste em dor abdominal, hamatêmese, melena e massa abdominal. Este caso refere-se a uma paciente com evolução de seis episódios de hemorragia digestiva alta em um período de cinco meses. Os autores revisam a literatura, discutem a enfermidade e relatam a história clínica, a propedêutica armada e o tratamento empregado


Asunto(s)
Humanos , Enfermedades de la Aorta/diagnóstico , Fístula Intestinal/diagnóstico , Fístula Vascular/diagnóstico
12.
RADIS dados ; (17): 1-31, dez.1995. ilus, tab
Artículo en Portugués | Sec. Est. Saúde SP, SESSP-ACVSES | ID: biblio-1065820

Asunto(s)
Brasil , Medicina
13.
J. bras. med ; 65(2): 49-50, ago. 1993. ilus
Artículo en Portugués | LILACS | ID: lil-173569

RESUMEN

Os autores relatam um caso de paciente feminina com massa pulsátil abdominal, anemia e velocidade de hemossendimentaçao elevada. Durante seis meses antes da internaçao referia dor lombar, febre e perda de peso importante. O diagnóstico de aneurisma inflamatório foi considerado no início, mas a cirurgia revelou dupla perfuraçao aórtica, resultando em pseudoaneurisma.


Asunto(s)
Femenino , Persona de Mediana Edad , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma Falso/diagnóstico , Aneurisma Falso/cirugía , Estudios de Seguimiento
14.
J. bras. med ; 64(4): 66, 68, abr. 1993. ilus
Artículo en Portugués | LILACS | ID: lil-188216

RESUMEN

Os autores relatam um caso de doença de Behçet, evoluindo com pseudoaneurismas das artérias femoral superficial direita, femoral comum direita e subclávia direita, relatando o tratamento cirúrgico e discutindo a evoluçäo.


Asunto(s)
Humanos , Masculino , Adulto , Aneurisma Falso/etiología , Síndrome de Behçet/complicaciones , Aneurisma Falso , Aneurisma Falso/cirugía , Angiografía
15.
J. bras. med ; 60(6): 88, 90, 92, jun. 1991. ilus
Artículo en Portugués | LILACS | ID: lil-196442

RESUMEN

Os autores relatam um caso de pseudoaneurisma da artéria glútea superior esquerda, analisando os métodos de diagnóstico, chamando a atençäo para o diagnóstico diferencial dos tumores localizados na regiäo glútea, descrevendo a técnica operatória e discutindo o caso.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Aneurisma Falso/diagnóstico , Aneurisma Falso/cirugía , Nalgas/irrigación sanguínea
16.
Rev. bras. cir ; 78(4): 241-5, jul.-ago. 1988. tab
Artículo en Portugués | LILACS | ID: lil-73308

RESUMEN

É analisada a experiência dos autores com 96 casos de perfuraçäo do esôfago. Säo salientadas as dificuldades iniciais encontradas na abordagem dos ferimentos do esôfago e citados os pontos de vista de determinados autores, que norteiam as condutas terapêuticas das perfuraçöes do esôfago, tendo um denominador comum para todos: a precocidade do tratamento. Menciona-se ainda a inexistência de um tratamento de eleiçäo - a näo ser a precocidade do tempo - salientando-se que a toracotomia e a rafia, quando precoces, ainda säo o melhor tratamento. Na experiência dos autores, o tratamento do suporte é satisfatório, tendo sido conduzido em vários pacientes com empiema, e que tiveram sobrevida. Mostra-se, finalmente, a validade da tomografia computadorizada para determinar se existem duas perfuraçöes, uma abdominal e outra torácica


Asunto(s)
Humanos , Perforación del Esófago/cirugía , Esofagostomía , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA