Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
Clin Diagn Lab Immunol ; 8(5): 1036-8, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11527826

RESUMEN

In patients with chronic paracoccidioidomycosis (n = 10), levels of tumor necrosis factor alpha, interleukin-10, and interleukin-2 in serum, measured by enzyme-linked immunosorbent assay (in picograms per milliliter, as mean +/- standard error of the mean), were higher than in normal controls (n = 8): 186 +/- 40 versus 40 +/- 7 (P < 0.05), 203 +/- 95 versus 20 +/- 8 (P = 0.001), and 96.3 +/- 78.57 versus 1.19 +/- 1.19 (P = 0.045), respectively. Gamma interferon and interleukin-4 levels were similar in patients and controls.


Asunto(s)
Interleucina-10/sangre , Paracoccidioidomicosis/inmunología , Factor de Necrosis Tumoral alfa/metabolismo , Adulto , Anciano , Animales , Enfermedad Crónica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paracoccidioidomicosis/sangre
6.
Am J Clin Pathol ; 111(3): 418-23, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10078119

RESUMEN

We developed a new method for the detection of large von Willebrand factor (vWf) multimers binding to collagen and for the determination of vWf antigen (vWf:Ag) using flow cytometry. Collagen is coated on to polystyrene beads, allowing detection of found large vWf multimers. In addition, rabbit antibody against vWf is coated on to the beads allowing detection of all vWf:Ag. In plasma samples from healthy persons and patients (with type 1, 2A, 2N, or severe von Willebrand disease or hemophilia), 4 different assays were performed: vWf:Ag by immunoelectrophoresis; vWf ristocetin cofactor (vWf:RCof); CBA; and vWf:Ag based on an enzyme-linked immunosorbent assay using polystyrene beads. We assayed the flow cytometric method using 2 bead sizes. The optimal bead size was 3.136 microns. The results of CBA and vWf:Ag closely correlated with those of vWf:RCof and vWf:Ag (immunoelectrophoresis), respectively, and showed a low limit of detection. Interassay variance of cytometric methods was lower than interassay variance of traditional assays. In addition, we used the new assays to monitor desmopressin therapy.


Asunto(s)
Colágeno/metabolismo , Citometría de Flujo/métodos , Factor de von Willebrand/metabolismo , Animales , Desamino Arginina Vasopresina/uso terapéutico , Ensayo de Inmunoadsorción Enzimática , Hemofilia A/sangre , Hemofilia A/diagnóstico , Humanos , Inmunoelectroforesis , Microesferas , Peso Molecular , Poliestirenos , Unión Proteica , Conejos , Valores de Referencia , Sensibilidad y Especificidad , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/tratamiento farmacológico , Factor de von Willebrand/análisis , Factor de von Willebrand/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA