1.
Pathol Biol (Paris) ; 46(1): 34-8, 1998 Jan.
Artículo en Francés | MEDLINE | ID: mdl-9769934

RESUMEN

The increase of endoscopic actions and infectious risks explains of interest in endoscopic material maintenance processing. This purpose study was to set to the point and validate a microbiological flexibles endoscopes channels (suction, biopsy, air/water) sample method. An inoculum made of faeces contents material and microorganisms suspension (Pseudomonas aeruginosa or Candida albicans), at low or high concentration, was injected into digestive endoscope's channels. For each microorganism, five trials were carried out at both of the two concentrations. After incubation, a global channels sample was performed with a recovering solution, then a counting was made. A variance analysis (ANOVA) concerning restated measures was performed for the whole results. The mean difference between the number of microorganisms injected and those recovered's is 0.114 log (IC95% [+0.088; +0.140]). It does not vary significantly according to the micro-organisms (p = 0.69) and the inoculum (p = 0.70). The coefficient of variation which is 0.525 (min: 0.010; max: 0.260) shows this method can be reproduced. This technique are allowed to be recommended to evaluate and to validate manuals and automatics endoscopes maintenance processing.


Asunto(s)
Endoscopios , Contaminación de Equipos , Análisis de Varianza , Técnicas Bacteriológicas , Desinfección , Reproducibilidad de los Resultados
2.
Ann Biol Clin (Paris) ; 52(11): 765-8, 1994.
Artículo en Francés | MEDLINE | ID: mdl-7747884

RESUMEN

A colorimetric method for the determination of zinc in serum was adapted for use with the Bayer RA 1000 autoanalyzer. Zinc is dissociated from proteins by guanidinium hydrochloride and complexed with 2-(5-bromo-2-pyridylazo)-5-(N-propyl-N- sulfopropylamino-)phenol (5-Br-PAPS). Precision (within-run CVs from 1.4 to 4.2%; between-run CVs from 3.5 to 8.1%), accuracy (93 to 103%) and detection limit (1.15 mumol/l) were sufficient for routine determinations. Moreover, results obtained with the proposed Bayer RA 1000 method were in good agreement with those obtained by flame atomic absorption spectrometry (FAAS) which could be considered the reference method. For 119 sera, the correlation coefficient r was found to be 0.958 and the regression line was as follows: serum zinc (RA 1000) = 0.96 serum zinc (FAAS) + 0.8 mumol/l. Moreover, 98% of the differences between colorimetry and FAAS were within the range Md +/- 1.96 SDd, where Md is the mean of the differences and SDd is the standard deviation of the differences.


Asunto(s)
Colorimetría/métodos , Zinc/sangre , Autoanálisis/instrumentación , Humanos , Espectrofotometría Atómica