1.
Small ; : e2401594, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38860544

RESUMEN

Defect engineering of metal-organic frameworks (MOFs) is a promising strategy for tailoring the interfacial characteristics between MOFs and polymers, aiming to create high-performance mixed matrix membranes (MMMs). This study introduces a new approach using dual defective alkylamine (AA)-modulated zeolitic imidazolate framework-8 (DAZIF-8), to develop high-flux MMMs. Tributylamine (TBA) and triethylamine (TEA) monodentate ligands coordinate with zinc ions in varying compositions. A mixture of Zn(CH3COO)2·2H2O:2-methylimidazole (Mim):AA in a 1:1.75:5 molar ratio facilitates high-yield coordination between Zn and multiple organic ligands, including Zn-Mim, Zn-TEA, and Zn-TBA (>80%). Remarkably, DAZIF-8 containing 3 mol% TBA and 2 mol% TEA exhibits exceptional characteristics, such as a Brunauer-Emmett-Teller surface area of 1745 m2 g-1 and enhanced framework rigidity. Furthermore, dual Zn-AA coordination sites on the framework's outer surface enhance compatibility with the polyimide (PI) matrix through electron donor-acceptor interactions, enabling the fabrication of high-loading MMMs with excellent mechanical durability. Importantly, the PI/DAZIF-8 (60/40 w/w) MMM demonstrates an unprecedented 759% enhancement in ethylene (C2H4) permeability (281 Barrer) with a moderate ethylene/ethane (C2H4/C2H6) selectivity of 2.95 compared to the PI, surpassing the polymeric upper limit for C2H4/C2H6 separation.

2.
Sci Adv ; 8(1): eabl6841, 2022 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-34985959

RESUMEN

Metal-organic frameworks with high aspect ratios have the potential to yield high-performance gas separation membranes. We demonstrate the scalable synthesis of high­aspect ratio zeolitic imidazolate framework (ZIF)­8 nanoplates via a direct template conversion method in which high aspect ratio­layered Zn hydroxide sheets [Zn5(NO3)2(OH)8] were used as the sacrificial precursor. Successful phase conversion occurs as a result of the collaboration of low template stability and delayed delivery of 2-methylimidazole in weakly interacting solvents, particularly using acetone. When the ZIF-8 nanoplates with an average aspect ratio of 20 were shear aligned in the 6FDA-DAM polymer matrix by bar coating, the separation performance for propylene/propane far surpassed that of the previously reported mixed matrix and polymeric membranes, showing a propylene permeability of 164 Barrer and selectivity of 33.4 at 40 weight % loadings.

3.
Spine (Phila Pa 1976) ; 47(10): 720-729, 2022 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-35019880

RESUMEN

STUDY DESIGN: Experimental study. OBJECTIVE: In this study, the ambient temperature of a radiofrequency (RF) electrode tip was compared and analyzed in terms of products, mode, flow quantity, and flow rate. SUMMARY OF BACKGROUND DATA: Endoscopic spine surgery is a widely used operation for degenerative lumbar stenosis and herniated lumbar disc. To perform endoscopic spine surgery, dedicated instruments like a RF generator and electrode are essential. METHODS: An evaluation system capable of measuring temperature under equal conditions at a certain distance from the electrode tip was manufactured. The distance between the electrode tip and the temperature sensor was set to 1, 5, and 10 mm. The flow quantities of 0, 50, 100, and 150 mL/min and the flow rates of 0, 0.20, 0.53, and 0.80 m/s were compared and statistically analyzed. RESULTS: The temperatures measured in the experiments conducted on the four combinations of RF device showed similar values, and showed differences according to the characteristics of each mode of the RF. As the distance between the electrode tip and the temperature sensor increased, the temperature decreased, and as flow quantity or flow rate increased, the temperature decreased. The maximum temperatures differed significantly according to flow quantity, between flow quantities of 0 and 100 mL/min (P  = 0.03) and between 0 and 150 mL/min (P ≤ 0.01). The maximum temperatures also differed significantly between the flow rate of 0 m/s, and the flow rates of 0.20, 0.53, and 0.80 m/s, with P ≤ 0.01 in all three comparisons. CONCLUSION: This is the first study in which we made a customized RF temperature evaluation system and verified the temperature changes in various environments. When irrigation was performed, we could confirm that the maximum temperature was less than 60°C. Irrigation is considered essential in endoscopic spine surgery. LEVEL OF EVIDENCE: 3.


Asunto(s)
Ablación por Catéter , Temperatura Corporal , Electrodos , Humanos , Modelos Teóricos , Temperatura
4.
Materials (Basel) ; 13(10)2020 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-32429282

RESUMEN

A series of UV-curable hybrid composite blends containing a carboxylic acid functionalized polyimidewith varying amounts of high molecular weight (~1 K) PEG-grafted ladder-structured polysilsesquioxanes copolymerized with methacryl groups were fabricated and their structural, thermal, mechanical, and surface properties characterized. At a composite weight ratio of polyimide above 50 wt.%, a stark shift from amorphous to crystalline polyethylene glycol (PEG) phases were observed, accompanied by a drastic increase in both surface moduli and brittleness index. Moreover, fabricated composites were shown to have a wide range water contact angle, 9.8°-73.8°, attesting to the tunable surface properties of these amphiphilic hybrid polymer composites. The enhanced mechanical properties, combined with the utility of tunable surface hydrophilicity allows for the possible use of these hybrid polymer composites to be utilized as photosensitive polyimide negative photoresists for a myriad of semiconductor patterning processes.