Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Optom Vis Sci ; 101(3): 164-172, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38546758

RESUMEN

SIGNIFICANCE: A snapshot intraocular pressure (IOP) is ineffective in identifying the IOP peak and fluctuation, especially during sleep. Because IOP variability plays a significant role in the progression of glaucoma, monitoring the IOP, especially during sleep, is essential to capture the dynamic nature of IOP. PURPOSE: We aimed to design an ocular pressure estimator (OPE) that can reliably and accurately measure the IOP noninvasively over closed-eyelid condition. METHODS: Ocular pressure estimator works on the principle that the external pressure applied by raising the IOP of the eyeball is transmitted through a compressible septum to the pressure sensor, thus recording the IOP. A fluid-filled pouch with a pressure sensor was placed over a rubber glove mimicking the eyelid (septum), covering the cornea of enucleated goat eyeballs. A pressure-controlled setup was connected to a goat cadaver eye, which was validated by a rebound tonometer. Cannulation of eyeballs through the lower limbus had the least difference from the control setup values documented using rebound tonometer, compared with cannulation through the optic nerve. Intraocular pressures ranging from 3 to 30 mmHg was induced, and the outputs recorded using OPE were amplified and recorded for 10 minutes (n = 10 eyes). We stratified the randomization of the number of times and the induced pressures. RESULTS: The measurements recorded were found to be linear when measured against an IOP range of 3 to 30 mmHg. The device has excellent reliability (intraclass correlation coefficient, 0.998). The repeatability coefficient and coefficient of variations were 4.24 (3.60 to 4.87) and 8.61% (7.33 to 9.90), respectively. The overall mean difference ± SD between induced IOP and the OPE was 0.22 ± 3.50 (95% confidence interval, -0.35 to 0.79) mmHg across all IOP ranges. CONCLUSIONS: Ocular pressure estimator offers a promising approach for reliably and accurately measuring IOP and its fluctuation noninvasively under a condition mimicking a closed eye.


Asunto(s)
Presión Intraocular , Tonometría Ocular , Animales , Reproducibilidad de los Resultados , Párpados , Cabras
2.
F1000Res ; 11: 223, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37771720

RESUMEN

Background: Emvolio is a non-medical device, indigenously developed portable refrigeration for maintaining the internal temperature 2-8˚C. The Indian Patent Office has granted patent for applications such as preservation and transport of medicines, vaccines, food, beverages, dairy etc. Further, use of Emvolio can be utilized in transport and store biologicals to preserve their biochemical and cellular integrity.  The objective of this study was to evaluate the biochemical and haematological integrity of biological samples such as rat blood, serum and liver. Methods: The steady temperature was maintained inside the Emvolio, and it was compared to that of thermocol and polypropylene boxes aided with frozen gel packs. The blood and liver samples were isolated from Wistar rats and kept in Emvolio, thermocol and polypropylene boxes for 10 hrs, and the temperature was monitored. The blood parameters, namely red blood cells (RBC), white blood cells (WBC), platelets, haematocrit, haemoglobin, mean corpuscular volume (MCV), mean corpuscular haemoglobin concentration (MCHC) and red cell distribution width (RDW), serum parameters like alanine transaminase, alkaline phosphatase, total protein, albumin, creatine kinase, blood urea nitrogen and liver parameters like superoxide dismutase (SOD), glutathione (GSH), catalase were estimated and compared. Results: Emvolio maintained a constant inner temperature range of 2-8˚C, whereas a significant temperature variation was seen in thermocol and polypropylene boxes. There was no significant deviation in the parameters tested when samples were kept in Emvolio for six hours compared to the zero hour readings. In contrast, there was a significant deviation among the parameters for the samples kept in thermocol and polypropylene boxes for six hours compared to zero hour parameters. Conclusions: Emvolio maintained constant temperature and preserved the biological integrity of rat blood, serum and liver. Thus, Emvolio can be efficiently used as a biological sample carrier, especially in preclinical studies.


Asunto(s)
Polipropilenos , Refrigeración , Ratas , Animales , Ratas Wistar , Índices de Eritrocitos , Hematócrito
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA